Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

feat(anta.tests): PtpGMStatus, PtpLockStatus, PtpModeStatus, PtpOffset, PtpPortModeStatus #564

Merged
merged 4 commits into from
Mar 7, 2024
Merged
Show file tree
Hide file tree
Changes from 1 commit
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
161 changes: 161 additions & 0 deletions anta/tests/ptp2.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,161 @@
# Copyright (c) 2024 Arista Networks, Inc.
# Use of this source code is governed by the Apache License 2.0
# that can be found in the LICENSE file.
"""
Test functions related to PTP tests
"""
# Mypy does not understand AntaTest.Input typing
# mypy: disable-error-code=attr-defined
from anta.decorators import skip_on_platforms
from anta.models import AntaCommand, AntaTest


class PtpModeStatus(AntaTest):
"""
This test verifies that the device is in Boundary Clock Mode
"""

name = "PtpModeStatus"
description = "Check Boundary Clock mode is enabled"
categories = ["hardware"]
commands = [AntaCommand(command="show ptp", ofmt="json")]

# Verify that all switches are running Boundary Clock

@skip_on_platforms(["cEOSLab", "vEOS-lab"])
@AntaTest.anta_test
def test(self) -> None:
command_output = self.instance_commands[0].json_output
ptp_mode = command_output["ptpMode"] if "ptpMode" in command_output.keys() else ""
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
if ptp_mode == "ptpBoundaryClock":
self.result.is_success(f"Valid PTP mode found: '{ptp_mode}'")
else:
self.result.is_failure(f"Device is not configured as a Boundary Clock: '{ptp_mode}'")


class PtpGMStatus(AntaTest):
"""
This test verifies that the device is locked to a valid GM
The user should provide a single "validGM" as an input
To test PTP failover, re-run the test with secondary GMid configured.
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Why should we re-run the test with another input? Can we just use a list of strings as input instead?

Copy link
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Do not want them to be hardcoded as they might be different for some other case, we give valid GM in the nrfu file so from there we are taking this value.

"""

class Input(AntaTest.Input): # pylint: disable=missing-class-docstring
validGM: str
""" expected validGM as input from the user in nrfu file"""
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved

name = "PtpGMStatus"
description = "Check device is locked to an allowed GM"
categories = ["hardware"]
commands = [AntaCommand(command="show ptp", ofmt="json")]

# Verify that all switches are locked to the same GMID, and that this GMID is one of the provided GMs

@skip_on_platforms(["cEOSLab", "vEOS-lab"])
@AntaTest.anta_test
def test(self) -> None:
command_output = self.instance_commands[0].json_output
validGM = self.inputs.validGM
ptp_gmid = command_output["ptpClockSummary"]["gmClockIdentity"] if "gmClockIdentity" in command_output["ptpClockSummary"].keys() else ""
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
# print(command_output["ptpClockSummary"]["gmClockIdentity"])
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved

if ptp_gmid == validGM:
self.result.is_success(f"Valid GM found: '{ptp_gmid}'")
else:
self.result.is_failure(f"Device is not locked to valid GM: '{ptp_gmid}'")


class PtpLockStatus(AntaTest):
"""
This test verifies that the device as a recent PTP lock
"""

name = "PtpLockStatus"
description = "Check that the device was locked to the upstream GM in the last minute"
categories = ["hardware"]
commands = [AntaCommand(command="show ptp", ofmt="json")]

# Verify that last lock time is within the last minute

@skip_on_platforms(["cEOSLab", "vEOS-lab"])
@AntaTest.anta_test
def test(self) -> None:
command_output = self.instance_commands[0].json_output
ptp_lastSyncTime = command_output["ptpClockSummary"]["lastSyncTime"] if "lastSyncTime" in command_output["ptpClockSummary"].keys() else ""
ptp_currentPtpSystemTime = (
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
command_output["ptpClockSummary"]["currentPtpSystemTime"] if "currentPtpSystemTime" in command_output["ptpClockSummary"].keys() else ""
)
# print(command_output["ptpClockSummary"])
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved

time_to_last_sync = ptp_currentPtpSystemTime - ptp_lastSyncTime

if time_to_last_sync <= 60:
self.result.is_success(f"Current PTP lock found: '{time_to_last_sync}'s")
else:
self.result.is_failure(f"Device Lock is old: '{time_to_last_sync}'s")


class PtpOmfStatus(AntaTest):
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
"""
This test verifies that the has a reasonable offset from master (jitter) level
"""

name = "PtpOfmStatus"
description = "Check that the Offset From Master is within +/- 1000ns"
categories = ["hardware"]
commands = [AntaCommand(command="show ptp monitor", ofmt="json")]

# Verify that offset from master is acceptable

@skip_on_platforms(["cEOSLab", "vEOS-lab"])
@AntaTest.anta_test
def test(self) -> None:
command_output = self.instance_commands[0].json_output
# print(command_output["ptpMonitorData"])
offsetMaxPos = 0
offsetMaxNeg = 0

for interface in command_output["ptpMonitorData"]:
# print(interface["offsetFromMaster"])
if interface["offsetFromMaster"] > offsetMaxPos:
offsetMaxPos = interface["offsetFromMaster"]
elif interface["offsetFromMaster"] < offsetMaxNeg:
offsetMaxNeg = interface["offsetFromMaster"]

if (offsetMaxPos < 1000) and (offsetMaxNeg > -1000):
self.result.is_success(f"Max Offset From Master (Max/Min): '{offsetMaxPos, offsetMaxNeg}'s")
else:
self.result.is_failure(f"Bad max Offset From Master (Max/Min): '{offsetMaxPos, offsetMaxNeg}'")


class PtpPortModeStatus(AntaTest):
"""
This test verifies that all ports are in stable PTP modes
"""

name = "PtpPortModeStatus"
description = "Check that all PTP enabled ports are not in transitory states"
categories = ["hardware"]
commands = [AntaCommand(command="show ptp", ofmt="json")]

# Verify that ports are either Master / Slave / Passive or Disabled
@skip_on_platforms(["cEOSLab", "vEOS-lab"])
@AntaTest.anta_test
def test(self) -> None:
validPortModes = ["psMaster", "psSlave", "psPassive", "psDisabled"]
invalidPorts = 0
command_output = self.instance_commands[0].json_output
# print(command_output["ptpIntfSummaries"])
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved

for interface in command_output["ptpIntfSummaries"]:
# print (interface)
# print(command_output["ptpIntfSummaries"][interface]["ptpIntfVlanSummaries"][0]['portState'])
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
for vlan in command_output["ptpIntfSummaries"][interface]["ptpIntfVlanSummaries"]:
# print(vlan['portState'])
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved
if not vlan["portState"] in validPortModes:
invalidPorts += 1
BarikiVarshitha marked this conversation as resolved.
Show resolved Hide resolved

if invalidPorts == 0:
self.result.is_success("Ports all in valid state")
else:
self.result.is_failure("Some ports are no in valid sates (Master / Slave / Passive / Disabled)")
Loading