Skip to content

Commit

Permalink
Fix IMU sensor refresh rate selection (#3642)
Browse files Browse the repository at this point in the history
* Fix sensor refresh rate selection

* Fix html

* Refactor
  • Loading branch information
haslinghuis committed Dec 1, 2023
1 parent 68e173b commit e18e363
Show file tree
Hide file tree
Showing 2 changed files with 14 additions and 3 deletions.
15 changes: 13 additions & 2 deletions src/js/tabs/sensors.js
Expand Up @@ -346,14 +346,25 @@ sensors.initialize = function (callback) {
const scales = {
'gyro': parseFloat($('.tab-sensors select[name="gyro_scale"]').val()),
'accel': parseFloat($('.tab-sensors select[name="accel_scale"]').val()),
'mag': parseFloat($('.tab-sensors select[name="mag_scale"]').val()),
'mag': parseInt($('.tab-sensors select[name="mag_scale"]').val(), 10),
};

// handling of "data pulling" is a little bit funky here, as MSP_RAW_IMU contains values for gyro/accel/mag but not altitude
// this means that setting a slower refresh rate on any of the attributes would have no effect
// what we will do instead is = determinate the fastest refresh rate for those 3 attributes, use that as a "polling rate"
// and use the "slower" refresh rates only for re-drawing the graphs (to save resources/computing power)
const fastest = d3.min([rates.gyro, rates.accel, rates.mag]);

let fastest;
// if any of the refresh rates change, we need to re-determine the fastest refresh rate
if (['gyro_refresh_rate', 'accel_refresh_rate', 'mag_refresh_rate'].includes($(this).attr('name'))) {
fastest = $(this).val();

$('.tab-sensors select[name="gyro_refresh_rate"]').val(fastest);
$('.tab-sensors select[name="accel_refresh_rate"]').val(fastest);
$('.tab-sensors select[name="mag_refresh_rate"]').val(fastest);
} else {
fastest = d3.max([rates.gyro, rates.accel, rates.mag]);
}

// store current/latest refresh rates in the storage
setConfig({'sensor_settings': {'rates': rates, 'scales': scales}});
Expand Down
2 changes: 1 addition & 1 deletion src/tabs/sensors.html
Expand Up @@ -128,7 +128,7 @@
<dl>
<dt i18n="sensorsRefresh"></dt>
<dd class="rate">
<select name="mag_refrash_rate">
<select name="mag_refresh_rate">
<option value="10">10 ms</option>
<option value="20">20 ms</option>
<option value="30">30 ms</option>
Expand Down

0 comments on commit e18e363