Skip to content

Commit

Permalink
Browse files Browse the repository at this point in the history
  • Loading branch information
pbellec committed Oct 29, 2019
2 parents f812b0a + bd93875 commit 40f7993
Showing 1 changed file with 23 additions and 3 deletions.
26 changes: 23 additions & 3 deletions source/MRI.md
Original file line number Diff line number Diff line change
@@ -1,13 +1,29 @@
# MRI

Magnetic resonance imaging (MRI) for the Courtois neuromod project is being acquired at the functional neuroimaging unit ([UNF](https://unf-montreal.ca/)), located at the "Centre de Recherche de l'Institut Universitaire de Gériatrie de Montréal" ([CRIUGM](http://www.criugm.qc.ca/)) and affiliated with [Université de Montréal](https://www.umontreal.ca/) as well as the [CIUSSS du Centre-Sud-de-l'île-de-Montréal](https://ciusss-centresudmtl.gouv.qc.ca/propos/services-en-anglais). The scanner is a Siemens Prisma fit, with a 64 channels head coil. Most imaging in the Courtois Neuromod project are composed solely of functional MRI runs. Periodically, an entire session is dedicated to anatomical scans. The scanning environment includes a number of stimulation and response equipment, detailed below.
Magnetic resonance imaging (MRI) for the Courtois neuromod project is being acquired at the functional neuroimaging unit ([UNF](https://unf-montreal.ca/)), located at the "Centre de Recherche de l'Institut Universitaire de Gériatrie de Montréal" ([CRIUGM](http://www.criugm.qc.ca/)) and affiliated with [Université de Montréal](https://www.umontreal.ca/) as well as the [CIUSSS du Centre-Sud-de-l'île-de-Montréal](https://ciusss-centresudmtl.gouv.qc.ca/propos/services-en-anglais). The scanner is a Siemens Prisma Fit, with a 64 channels head coil. Most imaging in the Courtois Neuromod project are composed solely of functional MRI runs. Periodically, an entire session is dedicated to anatomical scans. The scanning environment includes a number of stimulation and response equipment, detailed below.

## Personalized head cases
<img src="./_static/mri/headcase.png" alt="head case" width="200" align="right" hspace="10"/> In order to minimize movement during neuroimaging scans, each participant wears a custom-designed, personalized headcase built by a company called [Caseforge](https://caseforge.co) during scanning. The headcase are milled based on a scan of each participant's head generated using a handheld 3D scanner, as well as the shape of the MRI coil. Caseforge mills the personalized headcases in foam blocks.

## Auditory stimuli
## Stimuli

## Visual stimuli
### Visual presentation

All visual stimuli were presented with a projector onto a blank screen located in the MRI room, through a waveguide.

### Auditory system

For functional sessions, participant are equipped with MRI compatible headphone inserts.
On the computer used for stimuli presentation, a custom impulse response of the headphones is applied with an online finite impulse response filter using the LADSPA DSP to all the presented stimuli.
This impulse response was provided by the manufacturer.

### HCPTRT Stimuli

Eprime scripts provided by the Human Connectome project were adapted for our presentation system and used in the study

### Other stimuli

A custom overlay on top of Psychopy was used to present the different tasks and synchronize task with the scanner TTL.

## Video game controller

Expand All @@ -25,6 +41,7 @@ The Siemens pdf exam card of the anatomical sessions can be found [here](./_stat

### Brain


Localizer: ~0:21
ANA T1W: 6:38
ANA T2W: 5:57
Expand All @@ -38,6 +55,9 @@ T2_SWI_TRA_P2_!5MM: 4:54


### Cervical spinal cord

A detailed description of the protocol can be found here: [Spinal Cord MRI Protocols](https://osf.io/tt4z9/), including sequences ported to other MRI manufacturers.

Localizer: ~0:21
T2W: 4:02
*DWI gated: ~2:12
Expand Down

0 comments on commit 40f7993

Please sign in to comment.