Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
11 changed files
with
573 additions
and
97 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,15 @@ | ||
<Product Revision="1" xmlns="https://github.com/OpenZWave/open-zwave"> | ||
<MetaData> | ||
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0085:0012:0003</MetaDataItem> | ||
<MetaDataItem name="ProductPic">images/fakro/arz.png</MetaDataItem> | ||
<MetaDataItem id="0012" name="ZWProductPage" type="0003">https://products.z-wavealliance.org/products/677/</MetaDataItem> | ||
<MetaDataItem name="ProductPage">http://www.fakro.com/htmlen/379.php</MetaDataItem> | ||
<MetaDataItem name="Description">The ARZ SOLAR external roller shutters, powered by 12VDC, have been adapted for wireless cooperation with the Z-Wave system. The shutter is designed for FAKRO roof windows and its installation is possible at any time after roof window installation. It is also possible to use the shutter for roof windows of other manufactures. Installed on the outside of the window, the roller shutter constitutes an optimum solution against overheating and provides additional protection of the window e.g. against falling tree branches etc. The roller shutter enables complete blackout and good sound reduction. It is also good protection from glazing excessive cooling during the winter. The roller shutter also means increased security. It has built-in overload protection and can be controlled by using standard Z-Wave controller.</MetaDataItem> | ||
<MetaDataItem name="Name">ARZ SOLAR Roof Window Roller Shutter</MetaDataItem> | ||
<MetaDataItem id="0012" name="Identifier" type="0003">ARZ</MetaDataItem> | ||
<MetaDataItem id="0012" name="FrequencyName" type="0003">CEPT (Europe)</MetaDataItem> | ||
<ChangeLog> | ||
<Entry author="Justin Hammond - Justin@dynam.ac" date="03 May 2019" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/677/xml</Entry> | ||
</ChangeLog> | ||
</MetaData> | ||
</Product> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,15 @@ | ||
<Product Revision="1" xmlns="https://github.com/OpenZWave/open-zwave"> | ||
<MetaData> | ||
<MetaDataItem name="OzwInfoPage">http://www.openzwave.com/device-database/0085:0012:0003</MetaDataItem> | ||
<MetaDataItem name="ProductPic">images/fakro/arz.png</MetaDataItem> | ||
<MetaDataItem id="0004" name="ZWProductPage" type="0001">https://products.z-wavealliance.org/products/677/</MetaDataItem> | ||
<MetaDataItem name="ProductPage">http://www.fakro.com/htmlen/379.php</MetaDataItem> | ||
<MetaDataItem name="Description">Fakro ZRH12 Portable Remote Controller</MetaDataItem> | ||
<MetaDataItem name="Name">Fakro ZRH12 Portable Remote Controller</MetaDataItem> | ||
<MetaDataItem id="0004" name="Identifier" type="0001">ZRH12</MetaDataItem> | ||
<MetaDataItem id="0004" name="FrequencyName" type="0001">CEPT (Europe)</MetaDataItem> | ||
<ChangeLog> | ||
<Entry author="Michalux" date="11 May 2020" revision="1">Initial Metadata Import from Z-Wave Alliance Database - https://products.z-wavealliance.org/products/677/xml</Entry> | ||
</ChangeLog> | ||
</MetaData> | ||
</Product> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,88 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1"> | ||
<MetaData> | ||
<MetaDataItem name="Name">Namron Z-Wave Dimmer 400W</MetaDataItem> | ||
<MetaDataItem name="Description"> | ||
The in-wall dimmer is a Z-Wave device that is used to switch ON/OFF and adjust light intensity of the connected light. | ||
</MetaDataItem> | ||
<MetaDataItem name="ProductPic">images/namron/4512710.png</MetaDataItem> | ||
<MetaDataItem name="InclusionDescription">Triple click on the reset button or repower the device</MetaDataItem> | ||
<MetaDataItem name="ExclusionDescription">Triple click on the reset button</MetaDataItem> | ||
<MetaDataItem name="ResetDescription">Press and hold reset button for 10 seconds</MetaDataItem> | ||
<MetaDataItem id="d005" name="Identifier" type="0200">4512710</MetaDataItem> | ||
<ChangeLog> | ||
<Entry author="Nikhil André Luthra - nikhil.a.luthra@gmail.com" date="01 Nov 2020" revision="1">Handcrafted based on namron/1402756.xml and Vendors product manual</Entry> | ||
</ChangeLog> | ||
</MetaData> | ||
|
||
<!-- Configuration --> | ||
<CommandClass id="112"> | ||
<Value type="list" genre="config" instance="1" index="2" label="Saving load state before power failure" size="1" value="0"> | ||
<Help> | ||
Saving state before power failure. | ||
</Help> | ||
<Item label="Shutoff load" value="0"/> | ||
<Item label="Turn on load" value="1"/> | ||
<Item label="Save load state before power failure" value="2"/> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="3" label="Send Basic report" size="1" value="1"> | ||
<Help> | ||
Enable/disable to send the basic report to the Lifeline when the load state changed(When value set as 1, repower on the dimmer, it will send Basic report automatically) | ||
</Help> | ||
<Item label="Disable to send Basic report" value="0"/> | ||
<Item label="Enable to send Basic report" value="1"/> | ||
</Value> | ||
<Value type="byte" genre="config" instance="1" index="4" label="Fade time" min="0" max="127" value="1"> | ||
<Help> | ||
Default fade time (unit is second, this value has the same function as Duration of Multilevel). | ||
Valid value: 0~127 | ||
</Help> | ||
</Value> | ||
<Value type="byte" genre="config" instance="1" index="5" label="Minimum brightness" size="1" value="5"> | ||
<Help> | ||
Setting minimum brightness value. | ||
Valid value: 0~50, the bigger the value is, the higher the load’s minimum brightness is. | ||
</Help> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="6" label="MOSFET driving type" size="1" value="0"> | ||
<Help> | ||
Choose MOSFET driving type. | ||
</Help> | ||
<Item label="Trailing edge" value="0"/> | ||
<Item label="Leading edge" value="1"/> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="7" label="Add/remove through external switch" size="1" value="1"> | ||
<Help> | ||
Added to and removed from a network through external | ||
switch (when enables this function, triple press the external | ||
switch within 1.5 seconds to be added to or removed from a | ||
network) | ||
</Help> | ||
<Item label="Disable" value="0"/> | ||
<Item label="Enable" value="1"/> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="8" label="Dimming curve" size="1" value="0"> | ||
<Help> | ||
Setting dimming curve | ||
</Help> | ||
<Item label="linear dimming" value="0"/> | ||
<Item label="logarithmic dimming" value="1"/> | ||
</Value> | ||
<Value type="byte" genre="config" instance="1" index="9" label="Startup brightness of load" size="1" value="0"> | ||
<Help> | ||
Setting startup brightness of the load | ||
Valid value: 0~99 | ||
Note: every time when turn on the load from OFF status, if the | ||
target brightness is lower than the startup brightness, the | ||
brightness will first go to the startup brightness value then | ||
fall down to the target brightness | ||
</Help> | ||
</Value> | ||
</CommandClass> | ||
<!-- Association Groups --> | ||
<CommandClass id="133"> | ||
<Associations num_groups="1"> | ||
<Group index="1" max_associations="5" label="Lifeline"/> | ||
</Associations> | ||
</CommandClass> | ||
</Product> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,54 @@ | ||
<?xml version="1.0" encoding="utf-8"?> | ||
<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1"> | ||
<MetaData> | ||
<MetaDataItem name="Name">Namron Z-Wave Switch 400W</MetaDataItem> | ||
<MetaDataItem name="Description"> | ||
The in-wall switch is a Z-wave device that is used to switch ON/OFF the connected light and can be controlled by other Z-Wave devices. | ||
Supports S2 Unauthenticated. | ||
Supports OTA. | ||
</MetaDataItem> | ||
<MetaDataItem name="ProductPic">images/namron/4512715.png</MetaDataItem> | ||
<MetaDataItem name="InclusionDescription">Triple click on the reset button or repower the device</MetaDataItem> | ||
<MetaDataItem name="ExclusionDescription">Triple click on the reset button</MetaDataItem> | ||
<MetaDataItem name="ResetDescription">Press and hold reset button for 10 seconds</MetaDataItem> | ||
<MetaDataItem id="d006" name="Identifier" type="0200">4512715</MetaDataItem> | ||
<ChangeLog> | ||
<Entry author="Nikhil André Luthra - nikhil.a.luthra@gmail.com" date="01 Nov 2020" revision="1">Handcrafted based on namron/1402756.xml and Vendors product manual</Entry> | ||
</ChangeLog> | ||
</MetaData> | ||
|
||
<!-- Configuration --> | ||
<CommandClass id="112"> | ||
<Value type="list" genre="config" instance="1" index="2" label="Saving load state before power failure" size="1" value="2"> | ||
<Help> | ||
Saving state before power failure. | ||
</Help> | ||
<Item label="Shutoff load" value="0"/> | ||
<Item label="Turn on load" value="1"/> | ||
<Item label="Save load state before power failure" value="2"/> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="3" label="Send Basic report" size="1" value="1"> | ||
<Help> | ||
Enable/disable to send the basic report to the Lifeline when the load state changed(When value set as 1, repower on the dimmer, it will send Basic report automatically) | ||
</Help> | ||
<Item label="Disable to send Basic report" value="0"/> | ||
<Item label="Enable to send Basic report" value="1"/> | ||
</Value> | ||
<Value type="list" genre="config" instance="1" index="7" label="Add/remove through external switch" size="1" value="1"> | ||
<Help> | ||
Added to and removed from a network through external | ||
switch (when enables this function, triple press the external | ||
switch within 1.5 seconds to be added to or removed from a | ||
network) | ||
</Help> | ||
<Item label="Disable" value="0"/> | ||
<Item label="Enable" value="1"/> | ||
</Value> | ||
</CommandClass> | ||
<!-- Association Groups --> | ||
<CommandClass id="133"> | ||
<Associations num_groups="1"> | ||
<Group index="1" max_associations="5" label="Lifeline"/> | ||
</Associations> | ||
</CommandClass> | ||
</Product> |
Oops, something went wrong.