Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Manual&Step Trigger is not working #207

Closed
sujitth opened this issue Jun 20, 2018 · 1 comment
Closed

Manual&Step Trigger is not working #207

sujitth opened this issue Jun 20, 2018 · 1 comment
Assignees
Labels
Milestone

Comments

@sujitth
Copy link

sujitth commented Jun 20, 2018

  • Firmware version: V1.1.1
  • Shield version: Arduino-Crowdsupply
  • Powerboard version: R5B12

Expected behavior

when the manual&step trigger system is initiated the current channel setting value is outputted first and when triggered, the step value has to be updated to the channel output.

Actual behavior

Currently the output is OFF until triggered and only the step value is outputted to the channel when triggered.

How to reproduce

https://www.dropbox.com/s/8ijzgxc0jm726wi/DSCF6246.AVI?dl=0

@prasimix prasimix added the bug label Jun 20, 2018
@prasimix prasimix added this to the v1.2 milestone Jun 20, 2018
mvladic added a commit that referenced this issue Aug 27, 2018
mvladic added a commit that referenced this issue Aug 27, 2018
mvladic added a commit that referenced this issue Aug 27, 2018
@prasimix
Copy link
Member

Fixed, it should works now as in this video.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Projects
None yet
Development

No branches or pull requests

3 participants