Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Problème lecture EAIT à 0 #78

Open
fairecasoimeme opened this issue Jul 28, 2022 · 84 comments
Open

Problème lecture EAIT à 0 #78

fairecasoimeme opened this issue Jul 28, 2022 · 84 comments

Comments

@fairecasoimeme
Copy link
Owner

le cluster 0x0702 attribut 0x0001 remonte 0. #73

@fairecasoimeme
Copy link
Owner Author

Pouvez-vous donnez la valeur STGE cluster 0xff66 attribut 0x217 ?

@JSteunou
Copy link

JSteunou commented Jul 28, 2022

J'allais créer un ticket quand j'ai vu votre réponse.

Je ne vois pas de 0x217.

J'ai 0x0300 qui est à 1 (mode standard monophasé)

Update : j'étais en historique quand j'ai installé / configuré tout ça. Je suis passé en standard entre temps. Est-ce que ça joue ?

@fairecasoimeme
Copy link
Owner Author

Vous ne le voyez pas avec Deconz ? peut-être le rajouter dans le DDF

@JSteunou
Copy link

JSteunou commented Jul 28, 2022

Il n'apparait pas non.

image

Pas sûr que le DDF change quelque chose, c'est plutôt pour mapper des attributs avec l'API REST non ?

Je crois que @Smanar est l'expert là dessus, il saura mieux dire que moi.

@Smanar
Copy link

Smanar commented Jul 28, 2022

Hello, sur un OS classique tu as un fichier XML /usr/share/deCONZ/zcl/general.xml
Vers la ligne 3948 tu as le bloc lixee, la ligne a rajouter est celle du millieu

        <attribute id="0x0207" type="u16" name="Puissance app. Instantanée injectée" access="r" required="m" default="0x00"/>
        <attribute id="0x0217" type="cstring" name="Registre de Statuts" access="r" required="m"/>
        <attribute id="0x0300" type="u8" name="Protocole Linky" access="r" required="m" default="0x00"/>

Il faut par contre redemarrer deconz pour qu'il prenne en compte le nouveau XML.

@fairecasoimeme
Copy link
Owner Author

Merci @Smanar pour les infos.

@JSteunou
Copy link

Oui merci, j'ai pu avoir l'info du coup. Ça me dit : 003A0001

@fairecasoimeme
Copy link
Owner Author

Ok, la valeur en bit de 003A0001 est :
1110100000000000000001 avec le bit 8 correspondant au fonctionnement de votre linky. Vous pouvez retrouver ces informations sur le doc Enedis-NOI-CPT_54E.pdf (dispo sur le net)

Apparemment, votre Linky est en mode consommateur (même s'il remonte des étiquettes de production).

Je suis en contact avec Enedis qui me dit que c'est une erreur possible. Pour régler le problème, il m'a demandé votre PDL (numéro unique de votre linky) et votre ville. Vous pouvez me les envoyer par mail (contact[at]lixee.fr) et je ferais suivre.

@gsemet
Copy link

gsemet commented Jul 29, 2022

Je pense être dans le même problème, est ce que je peux contacter enedis directement ?

@JSteunou
Copy link

Ok c'est peut-être normal tant que le dossier CAC n'est pas entièrement validé (mais que c'est long...). Mais c'est dommage cette façon de faire car le Linky est capable de comptabiliser l'injection peu importe le mode‚ donc pourquoi ne pas juste transmettre l'info tout le temps ?

@JSteunou
Copy link

JSteunou commented Aug 2, 2022

@fairecasoimeme est-ce que ça veut dire que la TIC ne contient pas forcément tout ce qu'on peut lire physiquement sur son linky et que le ZLinky ne peut remonter qu'une partie des informations ?

@fairecasoimeme
Copy link
Owner Author

@JSteunou
je communique actuellement avec Enedis, voici un début de réponse sur votre cas :

Le compteur Linky associé au PDL xxxxxxxxxxxxxx est programmé en mode consommateur.

Dans ce mode, comme indiqué dans la note 54E, l'étiquette  EAIT (Energie active injectée totale) n'est pas transmise. Par ailleurs, le client ne dispose pas de contrat avec injection, uniquement soutirage.

Il est nécessaire que les clients aient un compteur configurés en mode producteur. Nous échangerons à le rentrée sur les conditions de basculement en configuration producteur.

@JSteunou
Copy link

JSteunou commented Aug 3, 2022

Ok donc si je comprends bien, pas de CACSI ou de CRAE pas de mode producteur et pas d EAIT transmise.

Aucun autre moyen de récupérer l'information ? Car côté Linky, je peux le lire, mais c'est juste pénible de faire du relevé manuel plusieurs fois par jour :/

@JSteunou
Copy link

JSteunou commented Aug 3, 2022

Et encore même pas sûr pour la CACSI du coup ça se trouve, vous avez l'info ?

@fairecasoimeme
Copy link
Owner Author

je fais suivre la question

@gsemet
Copy link

gsemet commented Aug 3, 2022

Alors pour ma part, j'ai la valeur toujours à zero et pourtant j'ai bien confirmé avec Enedis que mon compteur est en mode producteur.
Est-ce que je me serais pas trompé dans mon automatisation pour lire la valeur:

automation:
  - alias: Read ZLinky_TIC every minute
    description: ""
    trigger:
      - platform: time_pattern
        hours: "*"
        minutes: /1
        seconds: "0"
    condition: []
    action:
      - service: zha_toolkit.execute
        data:
          command: attr_read
          ieee: 00:15:8d:00:05:d2:a9:c5
          cluster: 1794 # 0x702
          attribute: 0 # 0x0000 : Energie active soutirée totale (Wh)
          state_id: sensor.lixee_zlinky_tic_consumed_metering_forced_refresh
          allow_create: false
      - service: zha_toolkit.execute
        data:
          command: attr_read
          ieee: 00:15:8d:00:05:d2:a9:c5
          cluster: 2820 # 0xB04
          attribute: 1295 # 0x050F # Puissance app. Instantanée soutirée (VA)
          state_id: sensor.lixee_zlinky_tic_consumed_power_forced_refresh
          allow_create: false
      - service: zha_toolkit.execute
        data:
          command: attr_read
          ieee: 00:15:8d:00:05:d2:a9:c5
          cluster: 1794 # 0x702
          attribute: 1 # 0x0001 : Energie active injectée totale (Wh)
          state_id: sensor.lixee_zlinky_tic_injected_metering_forced_refresh
          allow_create: false
      - service: zha_toolkit.execute
        data:
          command: attr_read
          ieee: 00:15:8d:00:05:d2:a9:c5
          cluster: 65382 # 0xFF66
          attribute: 519 # 0x0207 # Puissance app. Instantanée injectée (VA)
          state_id: sensor.lixee_zlinky_tic_injected_power_forced_refresh
          allow_create: false
    mode: single

@fairecasoimeme
Copy link
Owner Author

@gsemet pouvez vous remonter la valeur STGE ? cluster 0xff66 attribut 0x217 ?

@gsemet
Copy link

gsemet commented Aug 4, 2022

Alors avec la commande home assistant:

service: zha_toolkit.attr_read
data:
  ieee: 00:15:8d:00:05:d2:a9:c5
  cluster: 65382  # 0xFF66
  attribute: 535  # 0x217
  csvout: zlinky

Je lis la valeur suivante:

2022-08-04T11:41:49.645837+00:00,Manufacturer Specific,535,b'\x00\x00\x00\x00\x00\x00\x00\x00',0x0217,0xFF66,1,00:15:8d:00:05:d2:a9:c5,

@JSteunou
Copy link

Bon j'ai eu des infos de la part du support Enedis, pas de Linky en mode producteur si pas de CRAE. En CACSI ils ne touchent à rien donc la valeur ne remontera pas.

Pour tout ceux qui ont du PV ça veut dire EDF OA ou rachat par un autre qui veut bien (perso je n'en connais pas pour de l'auto installation) ou batterie virtuelle avec Urban Solar par exemple. Et si vous ne voulez (comme moi) pas vous emmerder avec Consuel et paperasse bin retour à la bonne vieille pince ampermetrique pour avoir son injection.

@Smanar
Copy link

Smanar commented Aug 21, 2022

Heu ...
L'info m'interesse, mais tu pourrais me dire ce que veut dire CRAE et CACSI ?

@JSteunou
Copy link

JSteunou commented Aug 21, 2022

CACSI : Convention d’AutoConsommation Sans Injection, c'est la demande de raccordement hyper basique dans laquelle Enedis se protège en demandant de ne rien injecter selon leur interprétation de la loi alors qu'on peut se permettre d'injecter un peu. Dans les faits, avec ou sans CACSI je crois que personne ne voit la différence.

CRAE : Contrat de Raccordement, d'Accès et d'Exploitation : là on arrive dans de l'injection officielle dans le réseau, soit avec revente soit cédé à titre gratuit, et apparemment il faudrait au minimum ça pour avoir son Linky en mode producteur.

Il manque un contrat de type CACAI (avec injection) qui satisferait tous les auto installateurs / consommateurs, sans Consuel, sans revente, sans limite d'injection, mais considéré comme producteur.

@fairecasoimeme
Copy link
Owner Author

D'après mon contact chez Enedis, il y a des discussions sur le passage en mode production. On a une réunion mi-septembre où on doit en parler. Je vous tiendrai au courant

@gsemet
Copy link

gsemet commented Sep 5, 2022

Bonjour. J'ai eu le support Enedis et ils m'ont bien confirmé que mon Linky était bien configuré en mode "producteur" (depuis 2018, j'ai mes facturations etc, pas de pbl), et pourtant je n'arrive toujours pas à lire de valeur injectée sur le réseau

@fairecasoimeme
Copy link
Owner Author

Bonjour,
la valeur de STGE que vous m'avez fourni plus haut semble être NULL. Serait-il possible de redemander la valeur correspondante à cluster: 0xFF66 attribut: 0x217 ? (ne pas mettre le manufacturer specific si possible)

@gsemet
Copy link

gsemet commented Sep 22, 2022

J'ai toujours la même valeure lue:

service: zha_toolkit.attr_read
data:
  ieee: 00:15:8d:00:05:d2:a9:c5
  cluster: 0xFF66
  attribute: 0x217
  csvout: zlinky

->

2022-09-22T11:42:44.008991+00:00,Manufacturer Specific,535,b'\x00\x00\x00\x00\x00\x00\x00\x00',0x0217,0xFF66,1,00:15:8d:00:05:d2:a9:c5,,0x41

Si je lis le cluster: 0x702 attribute: 0x0001

service: zha_toolkit.attr_read
data:
  ieee: 00:15:8d:00:05:d2:a9:c5
  cluster: 0x702
  attribute: 0x0001
  csvout: zlinky

->

2022-09-22T11:44:30.133005+00:00,ZLinkyTICMetering,current_summ_received,0,0x0001,0x0702,1,00:15:8d:00:05:d2:a9:c5,,0x25

Je pense qu'il y a un problème de remontée de cette information du linky mais Enedis me dis qu'il est configuré comme il faut en producteur, et j'ai vois bien ma production sur le site d'enedis...

Je suis en Firmware: 0x00000001, est ce que ça aiderait de faire la mise à jour ?

@fairecasoimeme
Copy link
Owner Author

@gsemet Oui pas normal de pas avoir la valeur STGE. C'est l'occasion de mettre à jour en effet.

@ddelpire
Copy link

ddelpire commented Nov 2, 2022

Bonsoir,
post très intéressant, je viens de comprendre pourquoi j'ai
image
alors que mon compteur m'affiche plus de 300kw de ré-injection mais j'ai le choix d'un contrat CACSI.

Donc ce n'est pas la sonde qui est en cause mais je croyais que la sonde Zlinky prenait ses infos sur le compteur pas en téléinfo. Là, j'ai du mal à comprendre, pourquoi allez récupérer les valeurs sur leurs serveurs alors qu'elles sont disponibles en locales.

Il n'y a donc aucune solution avec le Zlinky pour suivre sa ré-injection ? mon but était de pouvoir faire des scenari en cas de ré-injection.

Merci.

@VianneyHENON
Copy link

VianneyHENON commented Apr 6, 2023

@gsemet ça ne suffit pas, il faut le mode Standard producteur

@VianneyHENON en fait il manque un entre 2 côté enedis car la CACSI est censée être sans injection sauf que la loi nous autorise à injecter jusqu'à 3kW et à moins d'avoir un onduleur qui coupe / bride automatiquement, ce qui est non consommé est forcément injecté dans le réseau. Le pire c'est que le compteur Linky le comptabilise, mais côté TIC ça ne remonte pas.

Si tu ne parviens pas à récupérer les informations du TIC, essai avec une pince ampèremétrique connecté ou Sonoff Pow Elite, ou un plugin sur Domoticz ou Home assistant qui récupère les infos depuis le site ENEDIS, tel que DomoticzLinky que j'utilise depuis qqes années sur Domoticz.

Pour la pince ampèremétrique connecté ou Sonoff Pow Elite, tu dois pouvoir faire une règle de calcul en utilisant la valeur de production de ton onduleur, la valeur de ta consommation. Tu en déduis ce que tu ne consommes pas, donc ce que tu injectes.

@VianneyHENON
Copy link

VianneyHENON commented Apr 6, 2023

Merci pour vos retours. Je m'aperçois que je n'ai pas "réappairer" le lixee après le passage en mode producteur. Je voudrais donc tenter. Que dois faire, bien noté son nom, le supprimer et rester 10sec sur le bouton pour le redetecter/ renommer et hop ?

Oui, tu peux tu faire la procédure de réappairer, sinon supprimes complétement le lixee en avec la coche forcer la suppression. Tu réappaires, le renommer ne dois pas jouer, car homeassistant s'appuie sur l'id du sensor(lixee).

@bubar26
Copy link

bubar26 commented Apr 7, 2023

erf j'ai supprimé le lixee et impossible de le réappairer , plus rien de marche....
N'ayant pas de piste suppl. j'ai installé Z2MQTT, le lixee a pu être détecté et appairé après x tentative .
actuellement rien ne semble en vie, z2mqtt me déroute bcp je ne retrouve pas mes petits, et tout est en vrac... question d'habitude.
Très frustrant ce lixee.

@VianneyHENON
Copy link

erf j'ai supprimé le lixee et impossible de le réappairer , plus rien de marche.... N'ayant pas de piste suppl. j'ai installé Z2MQTT, le lixee a pu être détecté et appairé après x tentative . actuellement rien ne semble en vie, z2mqtt me déroute bcp je ne retrouve pas mes petits, et tout est en vrac... question d'habitude. Très frustrant ce lixee.

Il faut trouver ses repères, c'est que je me disait il y a qqes semaines, quand j'ai commencé à utiliser Home Assistant. :)

@bubar26
Copy link

bubar26 commented Apr 7, 2023

Je pense avoir une instabilité quelque part, les perf sont tres mauvaise depuis z2mqtt.
je ne suis pas bien certain du cheminement et des fonction de chaque module ou integration.
J'avais initialement le module Deconz pour la conbeeii
puis je l'ai désactivé pour mètre a la place l'intégration ZHA qui apriori nécessitait le module Mosquitto et l'intégration MQTT
Avec tout cela ca fonctionnait de maniere plutot fluide.
Maintenant j'ai désactivé ZHA et mis le module Z2Mqtt et Mosquitto est tjrs actif. est ce ok ?
par ou passer vous pour appairrer les device? L'UI de Z2Mqtt est tres tres lente...

@VianneyHENON
Copy link

VianneyHENON commented Apr 7, 2023

Je pense avoir une instabilité quelque part, les perf sont tres mauvaise depuis z2mqtt. je ne suis pas bien certain du cheminement et des fonction de chaque module ou integration. J'avais initialement le module Deconz pour la conbeeii puis je l'ai désactivé pour mètre a la place l'intégration ZHA qui apriori nécessitait le module Mosquitto et l'intégration MQTT Avec tout cela ca fonctionnait de maniere plutot fluide. Maintenant j'ai désactivé ZHA et mis le module Z2Mqtt et Mosquitto est tjrs actif. est ce ok ? par ou passer vous pour appairrer les device? L'UI de Z2Mqtt est tres tres lente...

Ah oui il faut désactiver deconz.
Je ne peux pas vous dire pour l'instabilité je n'utilise que le lixee en zigbee. Effectivement il faut installer mqtt + z2mqtt comme indiqué ici:
https://www.lesalexiens.fr/labo-test-alexa/test-du-lixee-zlinky-votre-consommation-electrique-sur-home-assistant-en-temps-reel/
Et pour l'appairage :
https://m.youtube.com/watch?v=1_pkEXI7ZSI

Si cela peut aider ;)
Autre chose, dans z2mqtt sélectionner le lixee puis menu Paramètres (spécifique) mettre la valeur measurement_poll_interval à 300 (soit 5 minutes) sinon votre bases de données va se remplir très/trop rapidement.

@bubar26
Copy link

bubar26 commented Apr 10, 2023

Je vais essayer ça merci. Apparemment il y a des soucis avec les conbee et z2mqtt. J'ai commandé une sonoff. J'attends de la recevoir.

@bubar26
Copy link

bubar26 commented Apr 13, 2023

Hello, pour un premier retour:
Avec la clé Sonoff Z2mqtt est plus stable, l'interface reagi correctement.
Je n'ai pas pu ré appairer mes plug tel quel, il a fallu que je les rapproche du controlleur, les debranché rebrancher plusieurs fois avant de pouvoir les retrouver.

Pour certaine prise je n'y arrive toujours pas: lors de l'appairage z2mqtt me met le popup rouge avec l'ID expliquant que le device a bien été retiré (???)
Si vous avez une idée je suis preneur.

Enfin l'objet essentiel de cette migration, le lixee n'est toujours pas détecté et lui je ne peux pas le rapprocher.
Même avec ZHA et Conbee c’était fastidieux, je vais d’abord trouvé un plug de plus pour densifié le maillage a proximité du lixee avant toute chose.

@bubar26
Copy link

bubar26 commented Apr 13, 2023

Une des prises que ne n'arrivai pas a ré appairée a pu l'etre apres l'avoir branchée ailleurs (plus loin du contrôleur pourtant ...)
avec un plug de plus a proximité, le Lixee est maintenant détecté mais comme Non Supporté.
J'ai tenté suppression forcée et ré appairage: idem
Une piste ?

@bubar26
Copy link

bubar26 commented Apr 15, 2023

J'ai réussi à rapprocher le contrôleur du lixee et j'ai enfin pu l'appairer. J'ai pu avoir accès un moment au info puis au fur et à mesure tous les devices sont tombés. Je vous épargne les divers essai de restart car au final J'ai l'impression que le lixee perturbe tous les autres. Lorsque cela fonctionne les device sont ok ds z2mqtt mais indisponible dans HA.
Je m'arrache les cheveux avec ce lixee

@VianneyHENON
Copy link

VianneyHENON commented Apr 15, 2023

J'ai réussi à rapprocher le contrôleur du lixee et j'ai enfin pu l'appairer. J'ai pu avoir accès un moment au info puis au fur et à mesure tous les devices sont tombés. Je vous épargne les divers essai de restart car au final J'ai l'impression que le lixee perturbe tous les autres. Lorsque cela fonctionne les device sont ok ds z2mqtt mais indisponible dans HA. Je m'arrache les cheveux avec ce lixee

Bonsoir,
Comme vous avez acheté une seconde clé zigbee (un sonoff je crois), est-ce que vous ne vous pas en utiliser un pour vos devices, et le second uniquement pour le lixee ? Je pense que 2 clé zigbee peuvent fonctionner ensemble car elles sont branchées sur 2 ports usb différents et en utilisant des canaux de communication différents.(https://www.home-assistant.io/integrations/zha/#defining-zigbee-channel-to-use)
Dans mon cas je n'utilise que le lixee comme device zigbee, donc je ne rencontre pas ce souci. Sinon posez la question sur vos problématiques de perturbation/déconnexion sur ce github et sur le forum home assistant. Peut-être aurez vous une réponse.
Cela m'intéresse si vous trouvez une solution.
En cherchant : je suis tombé sur cette discussion:
home-assistant/core#74830
Notamment : home-assistant/core#74830 (comment)
Il est vrai que j'ai branché ma clé conbee sur une rallonge usb pour l'éloigner du raspi 4 sur lequel, elle est branchée.
Quelques liens de recherche sinon:
https://forum.hacf.fr/t/lixee-zlinky-sous-zha-donnees-farfelues/20563/2
https://forum.hacf.fr/t/zlinky-tic-ou-connecter-simplement-linky-en-zigbee/7112/6
Dont l'outil de maillage: https://forum.hacf.fr/t/zlinky-tic-ou-connecter-simplement-linky-en-zigbee/7112/7
Ou encore : https://forum.hacf.fr/t/interferences-wifi-zigbee/10391
https://haade.fr/fr/blog/interference-zigbee-wifi-2-4ghz-a-savoir
https://forum.hacf.fr/t/gestion-des-canaux-zigbee-hue-ha/15915/3
#84
Bonne lecture.

@bubar26
Copy link

bubar26 commented Apr 16, 2023

Merci bcp pour tous les liens.
a priori les channel zigbee est wifi ne peuvent pas s'interferer, les 2 sont sur 11.
J'ai bien mis une rallonge (avec la conbee aussi il le fallait)
faute de resultat j'ai mis a jour HA core et mosquitto.
l'instabilité est toujour presence mais j'ai pu isoler le moment ou cela arrive, la ligne suivante se repete parfois 50 fois puis arrive a lire les data, puis plante sur l'adapter ezsp

les log du plantage :

zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
...
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
Zigbee2MQTT:info 2023-04-16 03:09:49: MQTT publish: topic 'zigbee2mqtt/Lixee_Zlinky_TIC', payload '{"active_enerfy_out_d01":9116,"active_enerfy_out_d02":7464,"active_enerfy_out_d03":1122,"active_enerfy_out_d04":2637,"active_power":450,"active_power_max":3080,"active_power_ph_b":502,"apparent_power":486,"available_power":9,"average_rms_voltage_meas_period":232,"current_date":"E230415224258","current_index_tarif":1,"current_price":"HC BLEU","current_summ_delivered":20341,"current_summ_received":141,"current_tarif":"TEMPO","current_tier10_summ_delivered":0,"current_tier1_summ_delivered":4954,"current_tier2_summ_delivered":12963,"current_tier3_summ_delivered":482,"current_tier4_summ_delivered":1153,"current_tier5_summ_delivered":213,"current_tier6_summ_delivered":577,"current_tier7_summ_delivered":0,"current_tier8_summ_delivered":0,"current_tier9_summ_delivered":0,"days_number_current_calendar":0,"days_number_next_calendar":0,"days_profile_current_calendar":"00004001 06004002 16004001 NONUTILE NONUTILE NONUTILE NONUTILE NONUTILE","days_profile_next_calendar":"","drawn_v_a_max_n1":4390,"injected_active_load_n":0,"injected_active_load_n1":0,"injected_v_a":0,"injected_v_a_max_n":860,"injected_v_a_max_n1":860,"linkquality":216,"message1":"PAS DE MESSAGE","message2":"","meter_serial_number":"811961211519","power_threshold":9,"reactive_power":2123,"reactive_power_ph_b":22683,"reactive_power_ph_c":16906,"relais":1,"rms_current":2,"rms_voltage":235,"site_id":"19773806022960","software_revision":2,"start_mobile_point1":0,"start_mobile_point2":0,"start_mobile_point3":0,"status_register":"013A0100","stop_mobile_point1":0,"stop_mobile_point2":0,"stop_mobile_point3":0,"total_reactive_power":8006,"update":{"installed_version":12,"latest_version":13,"state":"available"},"update_available":null}'
zlinky config: standard, single_phase, true, TEMPO
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["currentTarif"], {"sendWhen":"immediate","timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"srcEndpoint":null,"reservedBits":0,"manufacturerCode":null,"transactionSequenceNumber":null,"writeUndiv":false}) failed (sendZclFrameToEndpointInternal error)
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
zlinky config: standard, single_phase, true, TEMPO
Error: Reset error: Error: {"sequence":-1} after 10000ms
at /app/node_modules/zigbee-herdsman/src/adapter/ezsp/driver/uart.ts:298:23
at Queue.executeNext (/app/node_modules/zigbee-herdsman/src/utils/queue.ts:32:32)

@bubar26
Copy link

bubar26 commented Apr 17, 2023

J'ai l'impression que j'ai du mieux.
Pour éventuellement aider, j'ai supposé qu'il y avait trop de (mauvaise) info en même temps.
alors j'ai commencé par

  1. désactiver toute les intégrations qui n'ont rien a voir avec mon pb
    = moins d'activité

  2. refait le maillage en faisant les appairages depuis leur emplacement final en partant du plus pret du coordinateur (a la cave pres du lixee) vers le plus loin a l'exterieur (panneauPV au fond du jardin)
    = plein d'erreur des divers plug en moins, et des LQI plus elevés!

  3. tenté de régler la fréquence des infos Lixee
    =j'ai l'impression qu'il s'en fout de ce qu'on lui paramètre...

  4. je ne sais pas a quel moment, mais je n'avais pas remarqué la possibilité de MAJ le firmware du Lixee.
    Une fois avoir eu l'info que je pouvais passer en V13 j'ai lancé la MAJ
    Il a fallu X reboot de z2m et/ou HA + 2 Ré appairage du Lixee.....Et cela semble maintenant stable!

Je touche a rien pour valider.

@bubar26
Copy link

bubar26 commented Apr 18, 2023

finalement apres quelques heures (de nuit) le Lixee retombe en erreur du type :
...

<style> </style>

--
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysNumberCurrentCalendar"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysNumberNextCalendar"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysProfileCurrentCalendar"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysProfileNextCalendar"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haElectricalMeasurement(["totalReactivePower"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["meterSerialNumber"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier4SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier5SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier6SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier7SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier8SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier9SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier10SummDelivered"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["siteId"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["softwareRevision"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["availablePower"]
Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["powerThreshold"]

J'ai tenté de régler le poll Interval a 30 puis a 60 et cela semble etre respecté, le Lixee ne spam plus ses valeurs mais les envois bien 1 fois ( une salve de la meme trame repété 10 fois et ce toutes les 30 ou 60 seconde.

depuis le réglage a 60 sec, je n'ai plus les erreurs ci-dessus.
j'ai bien des valeur des les journaux de Z2mqtt mais :

  • les sensor sont noté indisponibles dans HA
  • le module Z2Mqtt restart plus que souvent
  • et les valeurs lixee n'apparaissent jamais ds HA
  • tout semble pourtant OK ds UI Z2Mqtt , si je change une config lixee elle est en success

le phénomène évolue...

J'ai voulu mettre l'option Herdman debug ds la configuration du module Z2M
restart du module et miracle le lixee revient et semble stable
je m'aperçois que mon sensor pour l'injection n'est pas bon (ID au lieu d'un nom), je corrige et l'injection remonte OK

a partir de ce moment le lixee se met a planter avec les meme erreur que plus haut
en revérifiant, l'option, le debug herdmann n'était pas mis ( la fatigue ou est ce que ca s'enlève au bout d'un moment c'est pas clair)

du coup maintenant:

  • lorsque que le lixee ne renvoi rien le reste du reseau Zigbee est fonctionnel
  • activer le herdman debug semble redonner vie au Lixee
  • des ques j'ai un valeur d'injection SINSTI, Z2M plante, et restart X fois
  • parfois seul le sensor injection est indispo sur le dashoard mais le reste marche durant un petit temps entre 5 et 10 minutes

@VianneyHENON
Copy link

VianneyHENON commented Apr 18, 2023

finalement apres quelques heures (de nuit) le Lixee retombe en erreur du type : ...

<style> </style>

-- Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysNumberCurrentCalendar"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysNumberNextCalendar"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysProfileCurrentCalendar"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 liXeePrivate(["daysProfileNextCalendar"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haElectricalMeasurement(["totalReactivePower"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["meterSerialNumber"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier4SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier5SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier6SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier7SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier8SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier9SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["currentTier10SummDelivered"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 seMetering(["siteId"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["softwareRevision"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["availablePower"] Failed to read zigbee attributes: Error: Read 0x00158d000638e2da/1 haMeterIdentification(["powerThreshold"]

J'ai tenté de régler le poll Interval a 30 puis a 60 et cela semble etre respecté, le Lixee ne spam plus ses valeurs mais les envois bien 1 fois ( une salve de la meme trame repété 10 fois et ce toutes les 30 ou 60 seconde.

depuis le réglage a 60 sec, je n'ai plus les erreurs ci-dessus. j'ai bien des valeur des les journaux de Z2mqtt mais :

* les sensor sont noté indisponibles dans HA

* le module Z2Mqtt restart plus que souvent

* et les valeurs lixee n'apparaissent jamais ds HA

* tout semble pourtant OK ds UI Z2Mqtt , si je change une config lixee elle est en success

le phénomène évolue...

J'ai voulu mettre l'option Herdman debug ds la configuration du module Z2M restart du module et miracle le lixee revient et semble stable je m'aperçois que mon sensor pour l'injection n'est pas bon (ID au lieu d'un nom), je corrige et l'injection remonte OK

a partir de ce moment le lixee se met a planter avec les meme erreur que plus haut en revérifiant, l'option, le debug herdmann n'était pas mis ( la fatigue ou est ce que ca s'enlève au bout d'un moment c'est pas clair)

du coup maintenant:

* lorsque que le lixee ne renvoi rien le reste du reseau Zigbee est fonctionnel

* activer le herdman debug semble redonner vie au Lixee

* des ques j'ai un valeur d'injection SINSTI, Z2M plante, et restart X fois

* parfois seul le sensor injection est indispo sur le dashoard mais le reste marche durant un petit temps entre 5 et 10 minutes

Vous allez finir par trouver :) Vous faites tourné HomeAssistant depuis quel équipement ? Raspberry pi, mini pc ?
L'idée d'utiliser une clé zigbee uniquement pour le lixee, n'est pas envisageable ? Comme vous avez 2 clés.

@bubar26
Copy link

bubar26 commented Apr 18, 2023 via email

@bubar26
Copy link

bubar26 commented Apr 19, 2023

Pardon , je n'ai pas reprécisé, oui un RPI 3.
pour tester avec 2 clés cela signifierait d'avoir (ZHA + conbee + tous les devices) + (Z2M + SOnOff + Lixee) ?
est ce vraiment possible cette conf ?

@VianneyHENON
Copy link

Pardon , je n'ai pas reprécisé, oui un RPI 3. pour tester avec 2 clés cela signifierait d'avoir (ZHA + conbee + tous les devices) + (Z2M + SOnOff + Lixee) ? est ce vraiment possible cette conf ?

Oui je pense, mais il faut préciser le second device USB dans le configuration.yaml

@bubar26
Copy link

bubar26 commented May 18, 2023

j'ai finalement réussi a m'en sortir :

  • en faisant un restart tous les quart d'heure de mosquitto et z2m, deja cela m'a permis d'avoir un systeme plus souvent up pour observer
  • en passant le delais (ds parametre suppl. du lixee) à 60
  • enfin en precisant une white list de ce que je souhaitais
    grace au paramètre du zlinky : EAST,EAIT,EASF01,EASF02,EASF03,EASF04,EASF05,EASF06,SINSTS,SINSTI,CURRENT_PRICE,LTARF

source: https://forum.hacf.fr/t/z2m-comment-filtrer-les-messages-envoyer-attribut/19391/17

apres cela j'ai pu retirer les restart automatique et remis un poll à 30 seconde.

le lixee est tout de meme sensible, un orage, une coupure, et le TIC est indisponible, il faut tenter de réappairer 2 ou 3 fois pour que Z2M le comprenne compatible, puis remettre la white et la limite à 30 sec,

En souhaitant que cela serve.

++

@nyroDev
Copy link

nyroDev commented Jun 22, 2023

@fairecasoimeme Je suis actuellement en attente de mon consuel pour valider mon contrat de vente et passer officiellement en producteur. Pour le moment, je ne reçois pas l'information via le TIC d'injection (mode standard) alors que le Linky l'affiche bien (total injecté et instantané)

Dès réception du consuel et validation par le service OA de mon compte producteur, j'espère avoir les informations qui remontent dans le TIC. Je ne manquerai pas de revenir ici pour confirmer ou infirmer ce point là.

Mon dossier a mis beaucoup de temps mais je confirme : dès le lendemain de la date de mise en service de revendeur par EDF, j'ai pu récupérer les données d'injection, après avoir réappairer le zlinky (Homeassistant via Zigbee2mqtt)

Et comme attendu, les données correspondent exactement à celles qui remontent sur Enedis dans mes données de production.

@freyermuth
Copy link

Bonjour @gsemet

Pourrais-tu nous donner la recette de ce beau graphique ?

image

Merci d'avance.
Thierry

@gsemet
Copy link

gsemet commented Aug 21, 2023

Salut,

C'est le dashboard "Energy" de home assistant (https://www.home-assistant.io/dashboards/energy/) une fois configuré avec les bonnes entrées:
image

Il y a les champs "ZLinky Energie Soutirée Totale" et "Zlinky Energie Injectée Totale" directement tirée du ZLinky, et ma production solaire (integration Solaredge pour moi). Il y a aussi une integration "prevision de production solaire" ("Forecast.Solar ") qui permet d'avoir un graph de prevision de production pour la journée.

Au total ca donne ce panneau très sympa:
image

Me manque juste la consommation d'eau

@fenjalbert
Copy link

Bonjour,
@gsemet As tu fait quelque chose de particulier pour avoir la valeur Zlinky energie Injectée totale ?

Quand je vais dans le menu energie, je ne trouve pas dans la liste ce paramètre. Je n'ai que les différents summation delivered de 0 à 6 et d'autres sources sans rapport avec Zlinky (Clim, Panneaux solaires).
Je précise je suis en CACSI, mais je m'attendrais à avoir la paramètre même avec une valeur à 0.

1
2

Bonne soirée

@gsemet
Copy link

gsemet commented Oct 24, 2023

Peut être parce que je passe par MQTT

image

@foXaCe
Copy link

foXaCe commented Nov 4, 2023

bonjour, moi aussi j'ai 0 en injection
comment vous faite pour savoir si votre compteur est bien en mode standard production ?

image

@Fyr42
Copy link

Fyr42 commented Apr 2, 2024

Bon j'ai eu des infos de la part du support Enedis, pas de Linky en mode producteur si pas de CRAE. En CACSI ils ne touchent à rien donc la valeur ne remontera pas.

Pour tout ceux qui ont du PV ça veut dire EDF OA ou rachat par un autre qui veut bien (perso je n'en connais pas pour de l'auto installation) ou batterie virtuelle avec Urban Solar par exemple. Et si vous ne voulez (comme moi) pas vous emmerder avec Consuel et paperasse bin retour à la bonne vieille pince ampermetrique pour avoir son injection.

Depuis cette date Enedis a mis plusieurs options DONT auto conso avec injection du surplus cédé à titre gratuit à Enedis. 6 options au lieu de 2 : cacsi et cae. Pas besoin de consuel si tu as un kit d'auto conso. Je suis passé en mode producteur récemment avec cette configuration Et j'ai la lettre P en bas sur l'affichage du Linky Je pense que je vais devoir re appairer le Lixee pour choper les valeurs

@VianneyHENON
Copy link

bonjour, moi aussi j'ai 0 en injection comment vous faite pour savoir si votre compteur est bien en mode standard production ?

image

bonjour, moi aussi j'ai 0 en injection comment vous faite pour savoir si votre compteur est bien en mode standard production ?

image

Sur ton compteur linky il est indiqué Standard TIC P
Standard/Historique = mode de télétransmission
P = Production

@VianneyHENON
Copy link

bonjour, moi aussi j'ai 0 en injection comment vous faite pour savoir si votre compteur est bien en mode standard production ?

image

Bon j'ai eu des infos de la part du support Enedis, pas de Linky en mode producteur si pas de CRAE. En CACSI ils ne touchent à rien donc la valeur ne remontera pas.
Pour tout ceux qui ont du PV ça veut dire EDF OA ou rachat par un autre qui veut bien (perso je n'en connais pas pour de l'auto installation) ou batterie virtuelle avec Urban Solar par exemple. Et si vous ne voulez (comme moi) pas vous emmerder avec Consuel et paperasse bin retour à la bonne vieille pince ampermetrique pour avoir son injection.

Depuis cette date Enedis a mis plusieurs options DONT auto conso avec injection du surplus cédé à titre gratuit à Enedis. 6 options au lieu de 2 : cacsi et cae. Pas besoin de consuel si tu as un kit d'auto conso. Je suis passé en mode producteur récemment avec cette configuration Et j'ai la lettre P en bas sur l'affichage du Linky Je pense que je vais devoir re appairer le Lixee pour choper les valeurs

Oui normalement cela devrait fonctionner.
Il faut paramétrer le zlinky dans la partie zigbee.

@Fyr42
Copy link

Fyr42 commented Apr 2, 2024

Bon je suis ZHA (du coup pas Z2M) et j'ai bien l'injection dans sensor.lixee_zlinky_tic_summation_received

J'ai supprimé et re appairé. mais je ne suis pas sûr que cela fût nécessaire. Enedis a configuré mon Linky samedi soir.

Par contre la lecture des attributs du Lixee m'informe que je suis en standard usuel non producteur Du coup je sais pas si c'est lié à mon type de contrat avec eux qui est sans revente. Un truc à mi chemin entre cacsi auto conso et sans index d'injection et le mode producteur full. Pour l'instant la lecture des autres paramètres "producteur" ne m'intéresse pas trop

@VianneyHENON
Copy link

VianneyHENON commented Apr 2, 2024

Bon je suis ZHA (du coup pas Z2M) et j'ai bien l'injection dans sensor.lixee_zlinky_tic_summation_received

J'ai supprimé et re appairé. mais je ne suis pas sûr que cela fût nécessaire. Enedis a configuré mon Linky samedi soir.

Par contre la lecture des attributs du Lixee m'informe que je suis en standard usuel non producteur Du coup je sais pas si c'est lié à mon type de contrat avec eux qui est sans revente. Un truc à mi chemin entre cacsi auto conso et sans index d'injection et le mode producteur full. Pour l'instant la lecture des autres paramètres "producteur" ne m'intéresse pas trop

Oui, je suis sous Zigbee2MQTT, donc je ne peux pas te dire.

Screenshot_2024-04-02-21-23-00-742_io homeassistant companion android
Screenshot_2024-04-02-21-24-41-203_io homeassistant companion android

Sinon utiliser un energy meter zigbee/wifi
J'en ai acheter avec pince ampèremètrique pour mesurer certain appareil comme chauffe eau, mais cela fonctionne aussi en branchant sur la phase de l'onduleur.

https://fr.aliexpress.com/item/1005005872383280.html?src=google&src=google&albch=shopping&acnt=248-630-5778&slnk=&plac=&mtctp=&albbt=Google_7_shopping&gclsrc=aw.ds&albagn=888888&isSmbAutoCall=false&needSmbHouyi=false&src=google&albch=shopping&acnt=248-630-5778&slnk=&plac=&mtctp=&albbt=Google_7_shopping&gclsrc=aw.ds&albagn=888888&ds_e_adid=&ds_e_matchtype=&ds_e_device=m&ds_e_network=x&ds_e_product_group_id=&ds_e_product_id=fr1005005872383280&ds_e_product_merchant_id=107736675&ds_e_product_country=FR&ds_e_product_language=fr&ds_e_product_channel=online&ds_e_product_store_id=&ds_url_v=2&albcp=19000710609&albag=&isSmbAutoCall=false&needSmbHouyi=false&gad_source=1&aff_fcid=16093761e2a84b21b7911c250efb277a-1712086240128-06925-UneMJZVf&aff_fsk=UneMJZVf&aff_platform=aaf&sk=UneMJZVf&aff_trace_key=16093761e2a84b21b7911c250efb277a-1712086240128-06925-UneMJZVf&terminal_id=7c8367e1f7974b02947df41b8b8fa5ed&afSmartRedirect=y

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests