Skip to content
This repository has been archived by the owner on Dec 14, 2017. It is now read-only.

Excel Addin: R404A wrong thermal conductivity #232

Closed
spiderpinne opened this issue Jul 28, 2014 · 4 comments
Closed

Excel Addin: R404A wrong thermal conductivity #232

spiderpinne opened this issue Jul 28, 2014 · 4 comments

Comments

@spiderpinne
Copy link

The Coolprop 4.2.0 Excel Addin returns thermal conductivity for R404A in the wrong decimal power.

The correct Value would be the returned value * 10 ^ 3.

@ibell
Copy link
Owner

ibell commented Jul 28, 2014

I made the fix locally, but didn't push it. I'll release 4.2.4 tonight
with this bug fixed. Alternatively you can build the DLL yourself.

On Mon, Jul 28, 2014 at 10:43 AM, spiderpinne notifications@github.com
wrote:

The Coolprop 4.2.0 Excel Addin returns thermal conductivity for R404A in
the wrong decimal power.

The correct Value would be the returned value * 10 ^ 3.


Reply to this email directly or view it on GitHub
#232.

@ibell
Copy link
Owner

ibell commented Jul 28, 2014

Build in progress, should be online in another hour or two.

On Mon, Jul 28, 2014 at 10:56 AM, Ian Bell ian.h.bell@gmail.com wrote:

I made the fix locally, but didn't push it. I'll release 4.2.4 tonight
with this bug fixed. Alternatively you can build the DLL yourself.

On Mon, Jul 28, 2014 at 10:43 AM, spiderpinne notifications@github.com
wrote:

The Coolprop 4.2.0 Excel Addin returns thermal conductivity for R404A in
the wrong decimal power.

The correct Value would be the returned value * 10 ^ 3.


Reply to this email directly or view it on GitHub
#232.

@ibell
Copy link
Owner

ibell commented Jul 28, 2014

Ok its online now. Can you please confirm that this fixes it?

On Mon, Jul 28, 2014 at 11:01 AM, Ian Bell ian.h.bell@gmail.com wrote:

Build in progress, should be online in another hour or two.

On Mon, Jul 28, 2014 at 10:56 AM, Ian Bell ian.h.bell@gmail.com wrote:

I made the fix locally, but didn't push it. I'll release 4.2.4 tonight
with this bug fixed. Alternatively you can build the DLL yourself.

On Mon, Jul 28, 2014 at 10:43 AM, spiderpinne notifications@github.com
wrote:

The Coolprop 4.2.0 Excel Addin returns thermal conductivity for R404A in
the wrong decimal power.

The correct Value would be the returned value * 10 ^ 3.


Reply to this email directly or view it on GitHub
#232.

@spiderpinne
Copy link
Author

Fix works! Thank you very much for the fast response!

@ibell ibell closed this as completed Jul 29, 2014