Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Fix heading annotation in fulltext evaluation and add header levels #1105

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -4,19 +4,20 @@
<fileDesc xml:id="0"/>
</teiHeader>
<text xml:lang="en">
<head>Introduction<lb/></head>
<head level="1">Introduction<lb/></head>

<p>It is known that acupuncture stimulation affects blood<lb/> flow, and there are some studies for skin <ref type="biblio">(1)</ref>, muscle <ref type="biblio">(2)</ref><lb/> and brain <ref type="biblio">(3)</ref>. We examined whether acupuncture not<lb/> only stimulates a local area but also the blood flow of<lb/> other organs, thus clarifying how acupuncture stimulates<lb/> an organism. Since it is necessary to examine the effect<lb/> on organ blood flow according to different areas of<lb/> stimulation, the blood flow of various organs was<lb/> measured in anesthetized rats using colored microspheres<lb/> that can quantitatively measure multiple organ blood<lb/> flow. We examined how acupuncture stimulation of the<lb/> regions (Hsia-Kuan or Hoku) influenced the blood<lb/> flow of various organs. Although microsphere measure-<lb/>ment for regional blood flow has radiolabeled micro-<lb/>spheres <ref type="biblio">(4-6,7-17,18)</ref> and colored microspheres <ref type="biblio">(19-28)</ref>,<lb/> we used the colored ones in this experiment. There are<lb/> two techniques for colored microsphere measurement.<lb/> One technique can calculate blood flow by counting the<lb/> total number of microspheres in each sample <ref type="biblio">(19-23)<lb/></ref> and the other by extracting colored dye from the<lb/> microsphere s <ref type="biblio">(24-28)</ref>. We used the latter technique in<lb/> our experiment.<lb/></p>

<head>Methods<lb/> Preparation<lb/></head>
<head level="1">Methods<lb/> </head>
<head level="2">Preparation<lb/></head>

<p>After 24 h without food, Male Wistar rats (n ¼ 27, body<lb/> weight: 250-420 g, free water intake) were anesthetized<lb/> with intra-peritoneal injection (1.2 g/kg) of urethane.<lb/> After tracheotomy, a cannula was inserted and a<lb/> respirator artificially regulated breathing (respiratory<lb/> frequency: 90 cycles/min, tidal air: 10 ml/kg, SN-480-7,<lb/> Shinano, Japan). Pancuronium bromide (2 mg/kg) was<lb/> administrated from a catheter that was placed in the<lb/> jugular vein of rats. In addition, CO 2 concentration in<lb/> the expiration was monitored (1H26, NEC) and main-<lb/>tained at about 3%. A second catheter (PE-50) was<lb/> positioned in the right femoral artery to monitor blood<lb/> pressure. The blood pressure and heart rate were<lb/> recorded on a thermal array recorder (RTA-1200,<lb/> Nihon Kohden). A third catheter (PE-10) was inserted<lb/> into left ventricular via the right carotid artery for the<lb/> colored microsphere injection. And, a fourth catheter<lb/> (PE-50) was positioned in the left femoral artery for<lb/> withdrawal of blood samples by a syringe pump at a rate<lb/> of 0.84 ml/min (Model210, KD Scientific Inc. USA). The<lb/> rectal temperature was monitored using a thermistor and<lb/> maintained about 37.5 C by means of a heating pad<lb/> (MK-900, Muromachi Kikai Co.). In this experiment,<lb/> yellow and blue microspheres (15 AE 0.2 mm, Dye-Track<lb/> Triton Technology Inc. USA) were used to measure<lb/> organ blood flow.<lb/></p>

<p>The experiment was divided into three groups. First<lb/> group comprised the controls (n ¼ 10, no stimulation).<lb/> Second group was stimulated with acupuncture for<lb/> 30 min at left ST-7 (n ¼ 10, ST-7 group). The third<lb/> group was stimulated by acupuncture for 30 min at<lb/> right LI-4 (n ¼ 7, LI-4 group). In the ST-7 group or LI-4<lb/> group, acupuncture was inserted into the left ST-7<lb/> (Hsia-Kuan, masseter muscle) or right LI-4 (Hoku)<lb/> point (LI-4 is located on the dorsum of the hand,<lb/> between the first and second finger) in the forelimb.<lb/> Acupuncture stimulation was given using rotation<lb/> (the needle was rotated right and left at 1 Hz) and was<lb/> repeated 10 times at intervals of 2 min.<lb/></p>

<p>The position of the left ventricle catheter was confirmed<lb/> by autopsy at the end of experiment.<lb/></p>

<head>Measurement of Blood Flow by Colored Microspheres<lb/></head>
<head level="2">Measurement of Blood Flow by Colored Microspheres<lb/></head>

<p>The infusion of colored microspheres started at least<lb/> 60 min after surgery and confirmation of stabilized<lb/> blood pressure and heartbeats. The microspheres were<lb/> stirred with a test tube mixer (NS-80, Iuchiseieidou) for<lb/> 5 min before infusion. The reference blood was drawn<lb/> from 10 s before the microsphere infusion, and continued<lb/> for 75 s. The microsphere (yellow or blue) infusion<lb/> (20 s) was started 10 s after beginning to draw blood.<lb/> Saline (0.5 ml) was then infused for 30 s to flush the<lb/> microspheres in the catheter. In all experiments, yellow<lb/> microspheres (0.12-0.14 ml, 360 000-420 000 micro-<lb/>spheres) were injected first and blue (0.2-0.23 ml,<lb/> 600 000-690 000 microspheres) ones second. After yellow<lb/> injection, additional fluid was not replaced except by<lb/> injection of blue. The injection of blue microspheres<lb/> started 30 min after the first blood sampling was finished<lb/> in the control group. In ST-7 or LI-4 group, acupuncture<lb/> stimulation was applied after the first sampling. About<lb/> 30 min after inserting the acupuncture needle, blue micro<lb/> spheres were injected.<lb/></p>

Expand All @@ -26,31 +27,31 @@

<p>Figure <ref type="figure">1</ref> shows examples of the absorbance by the<lb/> above processing. Since the peak of absorbance in yellow<lb/> microspheres appears at 448 nm wavelength and blue<lb/> appears at 672 nm (24,27), we measured 448 nm for<lb/> yellow microspheres in the blood sample of and 672 nm<lb/> for blue microspheres. Tissue samples containing both<lb/> microspheres were measured at wavelength absorbencies<lb/> of 448 nm and 672 nm. Tissue samples with no absor-<lb/>bency peak were deleted from our data.<lb/></p>

<head>Calculation of Organ Blood Flow<lb/></head>
<head level="2">Calculation of Organ Blood Flow<lb/></head>

<p>Organ blood flow was calculated using the equation<lb/> below:<lb/></p>

<formula>Qm ¼ ðAm  QrÞ=Ar<lb/></formula>

<p>Qm shows blood flow of the tissues (ml/min/g). Qr shows<lb/> the withdrawal rate of the blood samples. Am shows the<lb/> absorbance (AU) of the microspheres per 1 g. Ar shows<lb/> the absorbance (AU) of all microspheres in the blood<lb/> samples.<lb/></p>

<head>Statistical Analysis<lb/></head>
<head level="2">Statistical Analysis<lb/></head>

<p>Data were expressed as the mean AE SD. The percentage<lb/> changes of blood flow were expressed as 100% the first<lb/> value of blood flow, and the percentage was showed<lb/> by box and whisker plot. Wilcoxon signed rank test,<lb/> Mann-Whitney U-Test, One-way or Two-way ANOVA<lb/> was used for data analysis. Differences of P50.05 were<lb/> considered statistically significant.<lb/></p>

<head>Results<lb/></head>
<head level="1">Results<lb/></head>

<head>Time Courses of Mean Blood Pressure During<lb/> the Experiment in Control, ST-7 and LI-4 Groups<lb/></head>
<head level="2">Time Courses of Mean Blood Pressure During<lb/> the Experiment in Control, ST-7 and LI-4 Groups<lb/></head>

<p>Figure <ref type="figure">1</ref> shows the time course of mean blood pressure<lb/> (mmHg) in the control, ST-7 and LI-4 group. The mean<lb/> blood pressures before the first withdrawal in the control,<lb/> ST-7 and LI-4 were 76.0 AE 6.0, 80.7 AE 12.7 and<lb/> 86.4 AE 11.7. Although blood pressure of the control<lb/> group<lb/> tended<lb/> to<lb/> be<lb/> low,<lb/> there<lb/> was<lb/> no<lb/> significant difference among the three groups (P ¼ 0.15).<lb/> One-way ANOVA was applied to this analysis. The<lb/> temporal changes of blood pressure were also similar<lb/> among three groups, and no significant differences<lb/> (F(2,14) ¼ 1.94, P ¼ 0.17) and interaction (P ¼ 0.69)<lb/> among three groups. On the other hand, heart rate<lb/> (beats/min) before the first withdrawal of the control<lb/> group, ST-7 and LI-4 were 383.7 AE 25.3, 424.6 AE 40.3 and<lb/> 427.4 AE 27.6.There was no significant difference<lb/> [F(2,14) ¼ 3.02, P ¼ 0.07] and interaction (P ¼ 0.45)<lb/> among the three groups (data not shown). Two-way<lb/> ANOVA was applied to these analyses.<lb/></p>

<head>Organ Blood Flow in the Control Group<lb/></head>
<head level="2">Organ Blood Flow in the Control Group<lb/></head>

<p>The second measurements of organ blood flow were<lb/> slightly lower than those of the first in every organ, with<lb/> significant differences in the muscle, kidney, stomach,<lb/> brain and spleen (Fig. <ref type="figure">2</ref>). Wilcoxon signed rank test<lb/> was applied to these analyses and the mean variations<lb/> (ml/min/g) of first and second organ blood flow in each<lb/> organ were as follows; kidney: À0.65; small intestine:<lb/> À0.49; lung: À0.33; spleen: À0.32; stomach: À0.26; brain:<lb/> À0.17; muscle: À0.05; heart: À0.03 and liver: À0.02.<lb/></p>

<p>The first and second blood flow of the left masseter<lb/> muscle in the control group were 0.35 AE 0.24, 0.36 AE 0.45,<lb/> respectively (P ¼ 0.35, no figure), and right masseter<lb/> of the control group were 0.16 AE 0.18 and 0.12 AE 0.10,<lb/> and there was no significant difference (P ¼ 0.34,<lb/> no figure).<lb/></p>

<head>Change of Organ Blood Flow in the ST-7 Group<lb/></head>
<head level="2">Change of Organ Blood Flow in the ST-7 Group<lb/></head>

<p>Figure <ref type="figure">3</ref> shows the first and second organ blood flows in<lb/> the ST-7 group. Though the second blood flow was<lb/> slightly higher than the first blood flow in the muscle,<lb/> stomach, small intestine, brain and heart, there was<lb/></p>

Expand All @@ -66,11 +67,11 @@

<p>Mean percentage change of the left masseter stimulated<lb/> by acupuncture in the ST-7 group was þ57.2. The value<lb/> of the right masseter in the ST-7 group that was not<lb/> stimulated was þ28.9. The control group values were:<lb/> left masseter: À10.8; right masseter: À11.3. While<lb/> the blood flow rate decreased in both masseters of<lb/> the control group, the blood flow rate of the left<lb/> masseter of the ST-7 group had increased more than<lb/> the right of the same group. However, this difference<lb/> between the left and right masseters of the ST-7<lb/> group was not statistically significant. (Mann-Whitney<lb/> U-test).<lb/></p>

<head>Organ Blood Flow Change in the LI-4 Group<lb/></head>
<head level="2">Organ Blood Flow Change in the LI-4 Group<lb/></head>

<p>Figure <ref type="figure">5</ref> shows the first and second organ blood flow<lb/> measurements of the LI-4 group. Though the second<lb/> blood flow increased slightly more than the first in the<lb/> brain, lung and heart, there was no significant difference.<lb/> There was a significant decrease in the muscle. Wilcoxon<lb/> signed rank test was applied to these analyses. Mean<lb/> variation (ml/min/g) of blood flow of each organ blood<lb/> flow was: heart: þ2.15; lung: þ0.16; brain: þ0.11; liver:<lb/> 0.00; stomach: À0.01; muscle: À0.05; small intestine:<lb/> À0.18; spleen: À0.54 and kidney: À0.90. Figure <ref type="figure">6</ref> shows<lb/> the percentage change (%) of the control group and LI-4<lb/> group by box and whisker plot. There was no significant<lb/> difference between the control group and LI-4 group.<lb/> Mann-Whitney U-test was applied to these analyses.<lb/> Mean percentage change (%) of organ blood flow in LI-4<lb/> group were described subsequently; lung: þ46.3; heart:<lb/> þ34.7; brain: þ11.0; liver: þ7.4; small intestine: À1.1;<lb/> stomach: À10.8; kidney: À16.9; muscle: À30.0 and spleen:<lb/> À33.3.<lb/></p>

<head>Discussion<lb/></head>
<head level="1">Discussion<lb/></head>

<p>The colored microsphere technique used in this experi-<lb/>ment has various advantages for organ blood flow<lb/> measurement. It can measure blood flow of multiple<lb/> organs simultaneously. In principle, microspheres are<lb/> trapped at the peripheral capillary, and when infusion<lb/> volume increases, the measurement accuracy will rise<lb/> <ref type="biblio">(18)</ref>. However, disturbances may occur in the rat&apos;s<lb/> circulation. Kobayashi et al. <ref type="biblio">(22)</ref> described that a bolus<lb/> injection of less than one million colored microspheres<lb/> caused no significant hemodynamic disturbances in rats,<lb/></p>

Expand Down