Expand Up @@ -53,6 +53,7 @@ import groovy.transform.Field
@Field static int heatAlarm = 4
@Field static int heatAlarmHigh = 2
@Field static int heatAlarmLow = 6
@Field static int heatAlarmNormal = 0
@Field static int powerDisconnected = 2
@Field static int powerManagement = 8
@Field static int waterAlarm = 5
Expand All @@ -61,11 +62,11 @@ import groovy.transform.Field

@Field static Map configParams = [
inverseWaterValveReport: [num:17, label:"Inverse Water Valve Report", size:1],
tempUnit: [num:33, label:"Temperature Reporting Unit", size:1, defaultVal:2, options:[0:"Disabled", 1:"C", 2:"F [DEFAULT]"], hidden:true],
// tempUnit: [num:33, label:"Temperature Reporting Unit", size:1, defaultVal:2, options:[0:"Disabled", 1:"C", 2:"F [DEFAULT]"], hidden:true],
tempThreshold: [num:34, label:"Temperature Reporting Threshold (°F)", size:2, defaultVal:4, range:"0..255", isTempVal:true],
tempOffset: [num:35, label:"Temperature Sensor Offset (°F)", size:2, defaultVal:0, range:"-65536..65536", isTempVal:true],
// overheatAlarmTrigger: [num:36, label:"Overheat Alarm Trigger (°F)", size:2, defaultVal:104, range:"0..255", isTempVal:true],
// overheatCancelTrigger: [num:37, label:"Overheat Cancellation Trigger (°F)", size:2, defaultVal:86, range:"0..255", isTempVal:true],
tempOffset: [num:35, label:"Temperature Sensor Offset (°F)", size:2, defaultVal:0, range:"-255..255", isTempVal:true],
overheatAlarmTrigger: [num:36, label:"Overheat Alarm Trigger (°F)", size:2, defaultVal:104, range:"0..255", isTempVal:true],
overheatCancelTrigger: [num:37, label:"Overheat Cancellation Trigger (°F)", size:2, defaultVal:86, range:"0..255", isTempVal:true],
freezeAlarmTrigger: [num:40, label:"Freeze Alarm Trigger (°F)", size:2, defaultVal:32, range:"0..255", isTempVal:true],
freezeCancelTrigger: [num:41, label:"Freeze Cancellation Trigger (°F)", size:2, defaultVal:36, range:"0..255", isTempVal:true],
freezeAlarmValveControl: [num:42, label:"Valve Control with Freeze Alarm", size:1, defaultVal:1, options:[1:"Enabled [DEFAULT]", 0:"Disabled"]],
Expand Down Expand Up @@ -187,17 +188,12 @@ void executeConfigureCmds() {
runIn(6, refreshSyncStatus)

List<String> cmds = []

if (getParamStoredValue(configParams.inverseWaterValveReport.num) == null) {
cmds << configGetCmd(configParams.inverseWaterValveReport)
}


configParams.each { name, param ->
Integer storedVal = getParamStoredValue(param.num)
Integer settingVal = getSettingValue(param.num)
if ((settingVal != null) && (settingVal != storedVal)) {
logDebug "CHANGING ${param.label}(#${param.num}) from ${storedVal} to ${settingVal}"

logDebug "CHANGING ${param.label}(#${param.num}) from ${storedVal} to ${settingVal}"
if ((param == configParams.tempOffset) && (settingVal < 0)) {
// Adjust high byte for negative farenheit value
settingVal = ((settingVal * -1) + negativeParamValOffset)
Expand All @@ -207,9 +203,10 @@ void executeConfigureCmds() {
}
cmds << configSetCmd(param, settingVal)
cmds << configGetCmd(param)
} else if (getParamStoredValue(param.num) == null) {
cmds << configGetCmd(param)
}
}

if (cmds) {
sendCommands(cmds)
}
Expand All @@ -229,6 +226,14 @@ def setKeylockProtection(value) {
]
}

def on() {
open()
}

def off() {
close()
}

def close() {
logDebug "close()..."
return delayBetween([
Expand All @@ -255,8 +260,7 @@ def refresh() {
switchBinaryGetCmd(),
versionGetCmd(),
sensorBinaryGetCmd(),
sensorMultilevelGetCmd(tempSensorType),
configGetCmd(configParams.tempUnit),
sensorMultilevelGetCmd(tempSensorType),
configGetCmd(configParams.keylockProtection)
])

Expand Down Expand Up @@ -395,6 +399,15 @@ void zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevel
case tempSensorType:
def temp = convertTemperatureIfNeeded(cmd.scaledSensorValue, (cmd.scale ? "F" : "C"), cmd.precision)
sendEventIfNew("temperature", temp, true, temperatureScale)

// Manually implemented because the firmware has some bugs.
if (safeToInt(temp) >= safeToInt(getParamStoredValue(configParams.overheatAlarmTrigger.num), 999)) {
sendHeatAlarmEvent(heatAlarmHigh)
} else if (safeToInt(temp) <= getParamStoredValue(configParams.freezeAlarmTrigger.num)) {
sendHeatAlarmEvent(heatAlarmLow)
} else {
sendHeatAlarmEvent(heatAlarmNormal)
}
break
default:
logDebug "Unhandled: ${cmd}"