Simultaneous FUD on QC2 DDS hardware #54
Comments
The QC2 DDS hardware is AD9914. Where is this one-hot selection discussed http://www.analog.com/media/en/technical-documentation/data-sheets/AD9914.pdf On Sun, Jun 28, 2015 at 10:08 AM, Sébastien Bourdeauducq <
|
That has to do only with the connections external to the AD9914 chip. |
You mean Pin 58 on J0 to J10 of 11-slot motherboard which is routed to On Mon, Jun 29, 2015 at 7:40 AM, Sébastien Bourdeauducq <
|
It's not exactly what is normally called "latch", but yes. |
ARTIQ-Python rewrite of the DDS code is a good occasion for that. Only one-hot selection signals would need to be supported (#576). |
There seems to be no interest in this. Closing. |
Move some dependencies in to an artiq-master extra
The QC2 (clock lab) DDS hardware has one-hot selection signals, which makes it possible to FUD several channels at the same time.
The text was updated successfully, but these errors were encountered: