Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Thermal images problem #76

Closed
liaotianjiao opened this issue Aug 29, 2019 · 2 comments
Closed

Thermal images problem #76

liaotianjiao opened this issue Aug 29, 2019 · 2 comments

Comments

@liaotianjiao
Copy link

  There is a problem that confused me for a long time that Thermal images is really bad!!!When I turned on my device,the images shows on the screen can hardly recognize at all.There are many straight line refresh in high frequency and detected temperature is wrong too. I tested the Lepton alone,and it turn out to be good.so it's not the problem of device.And I find out that the images shows on the screen is zoom in? Because the feild of vision when I tested Lepton alone is different to DIY-Thermocam.
 Really appreciate your reply!!!  :)

}M@UCE7{X_N4ICOD}V}YYEP

@GuiotV
Copy link

GuiotV commented Jan 6, 2021

Hey i have the same issue did you find a solution to this ?

@GuiotV
Copy link

GuiotV commented Jan 31, 2021

Found it !!! The Sensor was pulled out of a Flir one Gen2 Android. And in the firmware the leptonhw was not detected and set to lepton2 without shutter which was wrong. It just need one more if with the right leptonhw see https://github.com/maxritter/diythermocam_firmware/blob/40e9c8a774ce4707db48dc1ce6462cbe0044825f/src/hardware/lepton.cpp#L578 . Since in the Flir one Gen2 is a lepton3 with higher Resolution than Lepton2. That is also why the picture was always only partly visible like in the image above.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

3 participants