Invalid reference to T_heatPort in line models #3096

Closed
beutlich opened this issue Aug 18, 2019 · 0 comments · Fixed by #3138
Closed

Invalid reference to T_heatPort in line models #3096

beutlich opened this issue Aug 18, 2019 · 0 comments · Fixed by #3138
Assignees
Labels
documentation Issue addresses the documentation L: Electrical.Analog Issue addresses Modelica.Electrical.Analog
Milestone

Comments

@beutlich
Copy link
Member

The three line models Modelica.Electrical.Analog.Lines.{OLine, M_OLine, ULine} mention T_heatPort in their parameter descriptions and documentation though there is no such variable.

@beutlich beutlich added L: Electrical.Analog Issue addresses Modelica.Electrical.Analog documentation Issue addresses the documentation labels Aug 18, 2019
@beutlich beutlich added this to the MSL4.0.0 milestone Aug 18, 2019
christiankral added a commit to christiankral/ModelicaStandardLibrary that referenced this issue Aug 26, 2019
In order to be more precise, T_heatPort is replaced by T_actual and T_actual is explained in the text, as this is mainly a documentation and not a code issue
dietmarw added a commit to dietmarw/ModelicaStandardLibrary that referenced this issue Oct 7, 2019
@beutlich beutlich assigned dietmarw and unassigned christophclauss Oct 8, 2019
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment