Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

EQUIPMENT IDENTIFIER is wrong for Fluvius meters when other mbus devices are present #133

Merged
merged 3 commits into from
Jul 11, 2023

Conversation

ejpalacios
Copy link
Contributor

Problem

When other devices are present via the WMBus, the signature for the EQUIPMENT_IDENTIFIER will match not only the ID of the meter but also the IDs of the MBus devices.

Cause

The parser will try to add every match to the telegram (telegram.add(obis_reference, dsmr_object)), overwriting in each attempt the previously mapped EQUIPMENT_IDENTIFIER. Eventually, only the last match which will be set as ID.
See objects.py line 33.

Why does the test pass?

If one try to access the field as telegram[obis.EQUIPMENT_IDENTIFIER] the correct ID is captured. This is because the "raw" obis references are only saved for their first occurrence.
See objects.py lines 42-43.

This last type of access is used in test_parse_fluvius.py line 36, which passes:

assert result[obis.EQUIPMENT_IDENTIFIER].value == '3153414733313031303231363035' # works

However, if the field is access with the mapping, it will not work:

assert result.EQUIPMENT_IDENTIFIER.value == '3153414733313031303231363035' # won´t work

Proposed fix

The easiest fix would be to change the telegram specification for the Fluvius meter in telegram_specifications.py line 148 from

obis.EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),

to

obis.BELGIUM_EQUIPMENT_IDENTIFIER: CosemParser(ValueParser(str)),

@ndokter
Copy link
Owner

ndokter commented Jul 4, 2023

I am aware of this problem. There is now support for multiple mbus devices:

https://github.com/ndokter/dsmr_parser#telegram-object

# All Mbus device readings like gas meters and water meters can be retrieved as follows. This
# returns a list of MbusDevice objects:
mbus_devices = telegram.MBUS_DEVICES

# A specific MbusDevice based on the channel it's connected to, can be retrieved as follows:
mbus_device = telegram.get_mbus_device_by_channel(1)
print(mbus_device.DEVICE_TYPE.value)  # 3
print(mbus_device.EQUIPMENT_IDENTIFIER_GAS.value)  # '4730303339303031393336393930363139'
print(mbus_device.HOURLY_GAS_METER_READING.value)  # Decimal('246.138')

I wonder if your fix by hardcoding the mbus channel will break implementations for other

@ejpalacios
Copy link
Contributor Author

The problem is not related to IDs of the mbus devices or channels but only with the ID of the main electricity meter.
When one or more mbus devices are present, the pattern

EQUIPMENT_IDENTIFIER = r'^\d-\d:96\.1\.1.+?\r\n'

matches not only the ID of the electricity meter

# ID of the Meter which should be in EQUIPMENT_IDENTIFIER
    '0-0:96.1.1(3153414733313031303231363035)\r\n'
    ...

but also the IDs other mbus devices, which overwrite its value.

# ID of MBUS device 1
    '0-1:96.1.1(37464C4F32313139303333373333)\r\n'
    ...
# ID of MBUS device 2 (actual value in EQUIPMENT_IDENTIFIER)
    '0-2:96.1.1(3853414731323334353637383930)\r\n'

Changing the telegram specification to match

BELGIUM_EQUIPMENT_IDENTIFIER = r'^\d-0:96\.1\.1.+?\r\n'

fixes the problem as it captures only the ID of the electricity meter, but indeed it means the Fluvius profile will not use the EQUIPMENT_IDENTIFIER field but rather the BELGIUM_EQUIPMENT_IDENTIFIER.

The issue can be reproduced with the script below.

from dsmr_parser.parsers import TelegramParser
from dsmr_parser import telegram_specifications
from test.example_telegrams import TELEGRAM_FLUVIUS_V171

parser = TelegramParser(telegram_specifications.BELGIUM_FLUVIUS)
result = parser.parse(TELEGRAM_FLUVIUS_V171)
print("elec meter ID: ", result.EQUIPMENT_IDENTIFIER)
print("mbus channel 2 meter ID: ", result.BELGIUM_MBUS2_EQUIPMENT_IDENTIFIER)

The output shows that EQUIPMENT_IDENTIFIER is wrong and was overwritten with the ID of the last mbus device.

# elec meter ID should be 3153414733313031303231363035
elec meter ID:  3853414731323334353637383930    [None]
mbus channel 2 meter ID:  3853414731323334353637383930  [None]

@ndokter
Copy link
Owner

ndokter commented Jul 4, 2023

I understand now, thank you for explaining. We only need to fix the issue with the pipeline before being able to merge

@ndokter ndokter merged commit 4602e8c into ndokter:master Jul 11, 2023
5 checks passed
@ndokter
Copy link
Owner

ndokter commented Jul 11, 2023

Thank you for your work! I've released it in v1.2.4

ejpalacios added a commit to ejpalacios/dsmr_parser that referenced this pull request Jul 13, 2023
…ces are present (ndokter#133)

* change obis of fluvius meter ID to BELGIUM_EQUIPMENT_IDENTIFIER
@ejpalacios ejpalacios deleted the bug/belgium-identifier-with-mbus branch January 8, 2024 10:58
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging this pull request may close these issues.