Add 'docs/hoc/' from commit '590f1bc0bd97814b6681c4771fac255d2fe25b51'
Browse files Browse the repository at this point in the history
git-subtree-dir: docs/hoc
git-subtree-mainline: b60d862
git-subtree-split: 590f1bc
  • Loading branch information
alexsavulescu authored and nrnhines committed Feb 9, 2021
1 parent 672a498 commit c339f35
Show file tree
Hide file tree
Showing 115 changed files with 35,943 additions and 0 deletions.
10 changes: 10 additions & 0 deletions docs/hoc/analysis/guitools.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,10 @@
GUI Analysis Tools
------------------

.. toctree::
:maxdepth: 3

guitools/funfit.rst
guitools/runfit.rst
guitools/mulfit.rst
guitools/impedancetools.rst
131 changes: 131 additions & 0 deletions docs/hoc/analysis/guitools/funfit.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,131 @@
.. _funfit:


FunctionFitter
--------------

A widget for graphing a parameterized function while exploring parameter
variations. Also can adjust the parameters automatically to fit data.
Function, parameters, independent variable can be specified by the user.
This widget may be saved in a session.

The FunctionFitter starts out with entries for graphing a single exponential
with two parameters. When a parameter value is changed the graph is replotted.

Plot
~~~~

Replots function with current arg values

Steps
~~~~~

Number of values of independent variable used in plot

IndependentVar
~~~~~~~~~~~~~~

Enter the name of independent variable in a
string dialog.

Args
~~~~

Enter space separated names of parameters in a string dialog.
Default value editors for these parameters will appear in the rightmost
box.

Yexpr
~~~~~

Enter an expression involving the independent variable and the
parameters (args). Any valid top level hoc expression is acceptable.

PraxisFit
~~~~~~~~~

Starts fitting the function to the data with respect to the DataWeights
by adjusting the checked argument values. See :func:`fit_praxis` .

StopAtNextQuadForm
~~~~~~~~~~~~~~~~~~

Stop the praxis fitter when it finishes its current/next cycle.
At this point it contains a computation of the quadratic form of the parameter
phase space (printed in the terminal window).

Running
~~~~~~~

Checked when the praxis fitter is executing.

WatchTheFit
~~~~~~~~~~~

Plot the function on each call to the error function during fitting.
Things are slower if this box is checked.

RoughFit
~~~~~~~~

Instead of fitting all the data according to the data weights, use
only 5 equally spaced points in each of the two central data regions.
Things can be much faster if this box is checked.

ArgValues
~~~~~~~~~

The values of the arguments are used in the plot. When a value
is changed the function is replotted. When fit data is present, a
checkbox is added to the left of each argument button. When the box is checked
then the fitter adjusts the value for a best fit. When not checked the parameter
is treated as a constant.

CurrentValuesAsDefault
======================

Resets the default values of the parameter field editors to their current values.


FittoData
~~~~~~~~~


ReadDataFile
============

Get data from a file. The format is the number of data points followed
by pairs of x,y data.

CommonFunctionalForms
=====================


FitCriterion
============

not implemented

ParameterRangeLimits
====================

Pops up a panel of parameters with their range limits. When
the fitter calls the error function and one of the parameters is
outside its range the error function will return a value of 1e6.

DataWeights
===========

Pops up a panel of data weight intervals and weights. The first interval
ranges from the beginning of the data to the interval 1 endpoint. From
the interval3 endpoint to the end of the data, the weight is 0. The entire
interval is given the weight indicated. Intervals can be manipulated directly
by the :guilabel:`AdjustWeightRegions` tool of the :guilabel:`Graph` menu.

SaveRestoreFunction
===================

Arg values and the y-expression can be saved in a list and restored by selection
with a browser.


71 changes: 71 additions & 0 deletions docs/hoc/analysis/guitools/impedancetools.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,71 @@
.. _attshape:

.. seealso: :ref:`impratio`, :ref:`impedance_impx`, :ref:`impedance_logavsx`,
Impedance Tools
---------------

These tools plot various functions of :class:`Impedance` vs
location and frequency. :ref:`impshape` is described below, but see also:

.. toctree:: :maxdepth: 1

impratio.rst
impedanx.rst


Each tool has three panels: The top
panel contains button and menu controls specific to the tool. The
middle panel displays a picture of the cell and marks the measurement
and injection sites. The bottom panel displays the results of the
impedance measurements.

The redraw button in the top panel forces a re-calculation of the results.
This is useful if a parameter or state changes in the underlying model
of the cell. The :menuselection:`Extras --> MovieMode` menu item recalculated the results
for each step during a :ref:`runcontrol_initrun`. When selected,
the :menuselection:`Extras --> AutoScale` rescales
the results panel after each calculation.

The :guilabel:`Plot` menu specifies whether to plot log attenuation (default),
input impedance, transfer impedance, or ``V(measure)/V(inject)``
Note: log attenuation is defined as ``ln( V(inject)/V(measure) )``
Input impedance is plotted with
respect to the measurement site and the injection site is unused.


.. _impshape:

ImpShape
~~~~~~~~

Tool for generating the neuromorphic rendering, a picture of the
neuron in which distance is scaled to represent the log of
voltage attenuation. In this transform,
long distance represents large attenuation.

The tool consists of three panels. The middle panel shows the normal
unscaled shape of the neuron on which the user can select a measurement/injection
site (default location is location 0 of the currently accessed section
when the ImpShape object was created). The lower panel displays
a neuromorphic rendering along with a unit attenuation scale bar.
The upper control panel allows selection of the frequency at which to
calculate the impedance and the direction of current flow, ``Vin/Vout``,
with respect
to the measurement/injection site.

When :guilabel:`Vin` is selected one can imagine that
for every point on the cell, that point is voltage clamped to 1 mV and
the voltage at the measurement site (0 end of the selected section in
the lower panel) is recorded. The shape of the neuron
is then plotted so that the distance between the
voltage clamp site and the measurement site is the natural
log of the attenuation
factor, ``ln( V(inject)/V(measure) )``

When :guilabel:`Vout` is selected, one can imagine that the selected position
becomes voltage clamped to 1mV and the voltage at every other position
on the cell is measured.


68 changes: 68 additions & 0 deletions docs/hoc/analysis/guitools/impedanx.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,68 @@
.. _impedanx:

.. _impedance_impx:

Impx
----


Tool for plotting voltage attenuation at a specific measurement/injection
site as
a function of selected path along the neuron at each point of which
current is injected/measured.

Frequency (Hz) of injected current is specified in the "frequency" field
editor.

The measurement/injection site is selected by first selecting the
:guilabel:`measure/inject` item of the :guilabel:`SelectLocation` menu and then selecting a
location on the neuron in the middle panel. A red dot denotes the
measurement (Vin mode) location or the injection location (Vout mode).
The end points of the path are selected by first
selecting the "path start" or "path end" menu items and then selecting a
location on the neuron in the middle panel.

The Vin and Vout radio buttons select whether the independent variable
in the results panel refers to injection position or measurement
position along the selected path.
The x=0 coordinate in the results section refers to the point on the
path that is closest to the root of the cell (The root is normally the
soma). Negative abscissa values are on the path start side and
positive values are on the path end side.

This tool uses the :class:`Impedance` class to calculate voltage
attenuations.


.. _impedance_logavsx:

LogAvsX
-------


Tool for plotting voltage attenuation at a specific measurement/injection
site as a function of Every point on the cell where current is
injected/measured. Abscissa in the results panel shows the distance
of every point from the root of the cell (usually soma(0)).

When the Vin radio button is selected the measurement site is fixed
(red dot) and the independent variable is the location of the injection
site. When Vout is selected, the independent variable is the measurement
location and the red dot refers to the fixed injection site.

In order to identify a particular section in the morphology panel
with a particular line segment in the results panel one can:

1) In the results panel use the graph menu (right mouse button) to select
the "ShowPosition" item. Then click (left mouse button) near the
beginning, end, or segment center of one of the lines. This will color red both
the line and the corresponding morphology section.

2) The meaning of the Section menu item in the morphology panel is
determined by the :guilabel:`ShapeSelectAction` menu item in the control panel.
When :guilabel:`MoveElectrode` is selected (and the Section menu item tool is also selected)
clicking on a section of the cell, changes the location of the 'fixed'
measurement/injection site (red dot). When :guilabel:`ShowPosition` is selected,
clicking on a section will color both the section and the corresponding
line in the results panel.

25 changes: 25 additions & 0 deletions docs/hoc/analysis/guitools/impratio.rst
Original file line number Diff line number Diff line change
@@ -0,0 +1,25 @@
.. _impratio:


ImpedanceRatio
--------------

Tool for plotting voltage attenuation or impedance at a specific measurement and
injection site as a function of log frequency from 0.1 to 1000 Hz.

The measurement site is selected by first selecting the :guilabel:`SelectMeasure` item
of the :guilabel:`SelectLocation` menu and then selecting a location on the neuron
in the middle panel. A red dot denotes the measurement location.
The injection site is selected by via selection of the :guilabel:`SelectInject` menu item.
Measurement and injection sites are indicated by red and blue dots respectively.
The :guilabel:`SwapMeasure/Inject` menu item swaps the measurement and injection sites.

The :guilabel:`Plot` menu specifies whether to plot log attenuation (default),
input impedance, transfer impedance, or ``V(measure)/V(inject)``.
Input impedance is plotted with
respect to the measurement site and the injection site is unused.

This tool uses the :class:`Impedance`
class to calculate voltage attenuations.