Skip to content

Commit

Permalink
Update Shield_CT1234_Voltage.ino
Browse files Browse the repository at this point in the history
  • Loading branch information
TrystanLea committed Jan 26, 2016
1 parent 9e75985 commit 2847b36
Showing 1 changed file with 16 additions and 0 deletions.
16 changes: 16 additions & 0 deletions emonTxShield/Shield_CT1234_Voltage/Shield_CT1234_Voltage.ino
Original file line number Diff line number Diff line change
Expand Up @@ -36,6 +36,20 @@
17-30 - Environmental sensing nodes (temperature humidity etc.)
31 - Special allocation in JeeLib RFM12 driver - Node31 can communicate with nodes on any network group
-------------------------------------------------------------------------------------------------------------
emonhub.conf node decoder:
See: https://github.com/openenergymonitor/emonhub/blob/emon-pi/configuration.md
[[6]]
nodename = emonTxShield
firmware =emonTxShield
hardware = emonTxShield
[[[rx]]]
names = power1, power2, power3, power4, Vrms
datacode = h
scales = 1,1,1,1,0.01
units =W,W,W,W,V
*/

#define FILTERSETTLETIME 5000 // Time (ms) to allow the filters to settle before sending data
Expand All @@ -55,6 +69,8 @@ const int networkGroup = 210; // emonT
#include "EmonLib.h"
EnergyMonitor ct1,ct2,ct3, ct4; // Create instances for each CT channel

// Note: Please update emonhub configuration guide on OEM wide packet structure change:
// https://github.com/openenergymonitor/emonhub/blob/emon-pi/configuration.md
typedef struct { int power1, power2, power3, power4, Vrms;} PayloadTX; // create structure - a neat way of packaging data for RF comms
PayloadTX emontx;

Expand Down

0 comments on commit 2847b36