Netlink Bandwidth Monitor in LUCI shows incorrect traffic value on Application protocol tab.
It seems Download (Bytes) and Upload (Bytes) are calculated/displayed incorrectly in the table. Pie graph looks OK. See attached screenshots.
LUCI version: (git-21.029.68283-bf8b0bb)
2021-02-02_09-03-09
2021-02-02_09-03-58
2021-02-02_09-05-03

@jow- jow- closed this as completed in 77d6b28 Mar 1, 2021
jow- added a commit that referenced this issue Mar 1, 2021
The pie chart tooltips used base 1000 to format traffic numbers while table
cell values were formatted using base 1024. Use base 1024 for both to report
the same values.

Fixes: #4759
Signed-off-by: Jo-Philipp Wich <jo@mein.io>
(cherry picked from commit 77d6b28)