Library implementation and CLI of the ISO EN 52000-1 "Energy performance of buildings" standard to explore NZEB indicators
This software implements the ISO EN 52000-1: Energy performance of buildings - Overarching EPB assessment - General framework and procedures standard.
The following assumptions have been taken:
- all weighting factors are constant through timesteps
- threre's no priority is set for energy production (average step A weighting factor f_we_el_stepA)
- all on-site produced energy from non cogeneration sources is considered as delivered
- the load matching factor is set to 1.0
- allow load matching factor values (or functions) that are not 1 (formula 32, B.32)
- get results by use items (by service), maybe using the reverse method E.3 (E.3.6, E.3.7)
To run the tests type make
on the command line.