Notifications
You must be signed in to change notification settings - Fork 16
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Can't run HSPEXP+ Number of Site are not in the correct format #36
Comments
Feel free to email me at amishra@ds-intl.biz if you want to resolve
this issue.
~A
***********************************
Anurag Mishra
…On Fri, Apr 12, 2019 at 11:45 AM kqasem ***@***.***> wrote:
Hi,
I am trying to run hydrology calibration using HSPEXP+. I added both
observed and simulated flows to the WDM. When hitting start, I get an error
saying the site locations are not in the correct format.
Any insights?
Thanks
Karoline Qasem, PhD
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#36>, or mute the thread
<https://github.com/notifications/unsubscribe-auth/AOYm5wfwVxMxC4ZjesWKhJCeppw6fHqlks5vgNRegaJpZM4cstp9>
.
|
Could you give us some more details about how you set up your EXS file(s)? And which version of HSPEXP+ you are running? |
Thanks @mishranurag I will sure email you. @PaulDudaRESPEC , are you referring to the ".exs" file? if yes, then i created it through WinHSPF --> calibration --> selected the observed and simulated reaches I want to calibrate. Then, a .exs was created. I am attaching a screen shot to the file. I am using HSPEXP + version 2.0 Please let me know if you have any thoughts. Thanks a lot! Karoline Qasem, PhD |
The name of WDM file is 9 characters. That has moved the line 2 by one character to the right. You should rename the WDM file so that it has less than or equal to eight characters and move the values on second line by 1 character to the left. |
Hi,
I am trying to run hydrology calibration using HSPEXP+. I added both observed and simulated flows to the WDM. When hitting start, I get an error saying the number of sites are not in the correct format.
Any insights?
Thanks
Karoline Qasem, PhD
The text was updated successfully, but these errors were encountered: