You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Smarter checking of incorrect settings in GannetPreInitialise.m in CheckTargets.m
Major changes to GannetFitPhantom.m to bring it more in line with GannetFit.m
Added support for CMRR MEGA-sLASER sequence in SiemensTwixRead.m
In SubSpectralAlign.m, if very strong water suppression was used, use Cho instead of residual water to align subspectra of GABA-, Lac-, and EtOH-edited datasets
Minor changes
Noise estimation in CalcNoise.m, Robust_Spectral_Registration.m, and SignalFilter.m is now performed between 8 and 10 ppm to account for datasets that have shorter spectral widths
Cleaned up code in GannetFit.m
Quantification of Lac now explicitly defined as Lac+MM
Improved functionality of PaperPlot.m
In SiemensTwixRead.m, when a water reference is present, coil sensitivity and phase is based on the point index that is at the top of the echo, rather than simply fixing it to the first point
Bug fixes
Minor bug fixes in CoRegStandAlone functions