You need to modify the IDD file that Eppy is using to add additional copies of that repeating field. C:\eppy046\resources\iddfiles |
Thank you!!! That makes sense. Can I use the same IDD file for other While I've got your attention, I'm also having trouble getting eppy to LPDlights = idf1.idfobjects['LIGHTS'] firstlight = lights[0] print firstlight Thanks so much!!! _Amalia Hicks, Ph.D._Director of Research On Mon, Dec 8, 2014 at 1:12 PM, Jason Glazer notifications@github.com
|
Amalia, |
Amalia, |
I am unable to recreate the front problem, I am closing this issue |
Ok, thanks! On Tuesday, December 16, 2014, santoshphilip notifications@github.com
|
Hi there,
Eppy is fabulous, thank you for creating it. I am having a slight problem with it breaking my idf file, however. I have a 3 story building with about 17 zones per floor. Each zone is included in a water outlet group, so in total I have 51 pieces of water use equipment.
When I run eppy on my input idf, it only transfers 10 pieces of water use equipment to the resulting idf file (under the WaterUse:Connections object). Subsequently, when I try to run the new idf file in E+ it crashes.
Any suggestions you could send along would be much appreciated. I can cut and paste the rest of the water use equipment into the new idf file, but that kind of cuts into eppy's usefulness...
Thanks so much for your help,
Amalia
WaterUse:Connections,
Water Outlet Group, !- Name
Water Outlet Group Water Inlet Node, !- Inlet Node Name
Water Outlet Group Water Outlet Node, !- Outlet Node Name
, !- Supply Water Storage Tank Name
, !- Reclamation Water Storage Tank Name
, !- Hot Water Supply Temperature Schedule Name
, !- Cold Water Supply Temperature Schedule Name
None, !- Drain Water Heat Exchanger Type
Plant, !- Drain Water Heat Exchanger Destination
1500.0, !- Drain Water Heat Exchanger UFactor Times Area
01FirstFloor:Office7 Water Outlet, !- Water Use Equipment 1 Name
01FirstFloor:Corridor Water Outlet, !- Water Use Equipment 2 Name
01FirstFloor:Office8 Water Outlet, !- Water Use Equipment 3 Name
01FirstFloor:Office1 Water Outlet, !- Water Use Equipment 4 Name
01FirstFloor:Office3 Water Outlet, !- Water Use Equipment 5 Name
01FirstFloor:Office2 Water Outlet, !- Water Use Equipment 6 Name
01FirstFloor:Office4 Water Outlet, !- Water Use Equipment 7 Name
01FirstFloor:Office6 Water Outlet, !- Water Use Equipment 8 Name
01FirstFloor:Office5 Water Outlet, !- Water Use Equipment 9 Name
01FirstFloor:Bathroom1 Water Outlet, !- Water Use Equipment 10 Name
[there should be 41 more items in this list]