Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Fixes Metastation AI core power issues #18945

Merged
merged 2 commits into from
Jun 28, 2016

Conversation

coiax
Copy link
Member

@coiax coiax commented Jun 26, 2016

  • The input and output on the SMES were wired together,
    resulting in the APC not charging.

🆑 coiax
fix: Fixes issue where the AI core APC on Metastation would not charge.
/:cl:

- The input and output on the SMES were wired together,
resulting in the APC not charging.

:cl: coiax
fix: Fixes issue where the AI core APC on Metastation would
not charge.
/:cl:
@MrStonedOne
Copy link
Member

Seems like a better fix would be to make the /core/ smes have a higher output than input or disable charging

@ChangelingRain
Copy link
Contributor

SMES units aren't supposed to have connected input and output unless engineers are fucking with em.

@ChangelingRain ChangelingRain merged commit cfda195 into tgstation:master Jun 28, 2016
@coiax coiax deleted the fix-metastation-ai-power branch January 18, 2021 16:05