SONOFF POW cant calibrate power settings Again :( #676

Closed
gibbo520 opened this issue Mar 14, 2018 · 7 comments
Closed

SONOFF POW cant calibrate power settings Again :( #676

gibbo520 opened this issue Mar 14, 2018 · 7 comments
Assignees
Milestone

Comments

@gibbo520
Copy link

#194

Same problem in Version 1.12.4

@xoseperez xoseperez added this to the 1.12.5 milestone Mar 15, 2018
@xoseperez xoseperez self-assigned this Mar 15, 2018
@xoseperez
Copy link
Owner

Do you mean the calibration values are not persisted?

@gibbo520
Copy link
Author

gibbo520 commented Mar 15, 2018 via email

@zerog2k
Copy link
Contributor

zerog2k commented Mar 17, 2018

I have KMC-70011 (w/ HLW8012), ESPURNA 1.12.5a
Also, unable to calibrate energy monitor settings - they are way off.
Calibration using 50W resistive incandescent light bulb, and calibration settings are not saving/taking effect.

update, example discrepancies, attempted to set:
expected current: 0.414
expected voltage: 120
expected power: 50

the readings from espurna don't really change, and are more than 2x reality:

{"current":"0.995","voltage":"123","power":"132","reactive":"0","apparent":"122","factor":"100","energy":"0.046","time":"2018-03-17 15:21:17","mac":"<<redacted>>","host":"ESPURNA_237195","ip":"192.168.1.18","id":658160}

@gn0st1c
Copy link
Contributor

gn0st1c commented Mar 17, 2018

@xoseperez : btw, for KMC 70011 HLW8012_VOLTAGE_R_UP is 2 * 1000000 (2 x 105 resistors)

@xoseperez
Copy link
Owner

Staged for release

@karmacoma92
Copy link

karmacoma92 commented Jul 19, 2018

Hi again, something similar is happening in 1.13.1. I just got the POW and it is the first time I use it so I'm not sure if there is any special procedure for the calibration rather than connect it to a bulb, switch it on and write down the values under sensors... but I loose the values I write right after pressing "Save"

@karmacoma92
Copy link

it looks to me the chip at the back is a CSE7759 and not a CSE7766, could that be the problem?
I have tried with 1.12.6 pow and powr2, 1.13.0 POW and POWR2 and 1.13.1 POW and POWR2, none of them allows me to store the values....

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Projects
None yet
Development

No branches or pull requests