AP_Baro_MS5611.cpp
492 lines (411 loc) · 13.9 KB
/
AP_Baro_MS5611.cpp
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
/*
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
#include "AP_Baro_MS5611.h"
#include <utility>
#include <stdio.h>
#include <AP_Math/AP_Math.h>
#include <AP_Math/crc.h>
extern const AP_HAL::HAL &hal;
static const uint8_t CMD_MS56XX_RESET = 0x1E;
static const uint8_t CMD_MS56XX_READ_ADC = 0x00;
/* PROM start address */
static const uint8_t CMD_MS56XX_PROM = 0xA0;
/* write to one of these addresses to start pressure conversion */
#define ADDR_CMD_CONVERT_D1_OSR256 0x40
#define ADDR_CMD_CONVERT_D1_OSR512 0x42
#define ADDR_CMD_CONVERT_D1_OSR1024 0x44
#define ADDR_CMD_CONVERT_D1_OSR2048 0x46
#define ADDR_CMD_CONVERT_D1_OSR4096 0x48
/* write to one of these addresses to start temperature conversion */
#define ADDR_CMD_CONVERT_D2_OSR256 0x50
#define ADDR_CMD_CONVERT_D2_OSR512 0x52
#define ADDR_CMD_CONVERT_D2_OSR1024 0x54
#define ADDR_CMD_CONVERT_D2_OSR2048 0x56
#define ADDR_CMD_CONVERT_D2_OSR4096 0x58
/*
use an OSR of 1024 to reduce the self-heating effect of the
sensor. Information from MS tells us that some individual sensors
are quite sensitive to this effect and that reducing the OSR can
make a big difference
*/
static const uint8_t ADDR_CMD_CONVERT_PRESSURE = ADDR_CMD_CONVERT_D1_OSR1024;
static const uint8_t ADDR_CMD_CONVERT_TEMPERATURE = ADDR_CMD_CONVERT_D2_OSR1024;
/*
constructor
*/
AP_Baro_MS56XX::AP_Baro_MS56XX(AP_Baro &baro, AP_HAL::OwnPtr<AP_HAL::Device> dev, enum MS56XX_TYPE ms56xx_type)
: AP_Baro_Backend(baro)
, _dev(std::move(dev))
, _ms56xx_type(ms56xx_type)
{
}
AP_Baro_Backend *AP_Baro_MS56XX::probe(AP_Baro &baro,
AP_HAL::OwnPtr<AP_HAL::Device> dev,
enum MS56XX_TYPE ms56xx_type)
{
if (!dev) {
return nullptr;
}
AP_Baro_MS56XX *sensor = new AP_Baro_MS56XX(baro, std::move(dev), ms56xx_type);
if (!sensor || !sensor->_init()) {
delete sensor;
return nullptr;
}
return sensor;
}
bool AP_Baro_MS56XX::_init()
{
if (!_dev) {
return false;
}
_dev->get_semaphore()->take_blocking();
// high retries for init
_dev->set_retries(10);
uint16_t prom[8];
bool prom_read_ok = false;
_dev->transfer(&CMD_MS56XX_RESET, 1, nullptr, 0);
hal.scheduler->delay(4);
const char *name = "MS5611";
switch (_ms56xx_type) {
case BARO_MS5607:
name = "MS5607";
FALLTHROUGH;
case BARO_MS5611:
prom_read_ok = _read_prom_5611(prom);
break;
case BARO_MS5837:
name = "MS5837";
prom_read_ok = _read_prom_5637(prom);
break;
case BARO_MS5637:
name = "MS5637";
prom_read_ok = _read_prom_5637(prom);
break;
}
if (!prom_read_ok) {
_dev->get_semaphore()->give();
return false;
}
printf("%s found on bus %u address 0x%02x\n", name, _dev->bus_num(), _dev->get_bus_address());
// Save factory calibration coefficients
_cal_reg.c1 = prom[1];
_cal_reg.c2 = prom[2];
_cal_reg.c3 = prom[3];
_cal_reg.c4 = prom[4];
_cal_reg.c5 = prom[5];
_cal_reg.c6 = prom[6];
// Send a command to read temperature first
_dev->transfer(&ADDR_CMD_CONVERT_TEMPERATURE, 1, nullptr, 0);
_state = 0;
memset(&_accum, 0, sizeof(_accum));
_instance = _frontend.register_sensor();
_dev->set_device_type(DEVTYPE_BARO_MS5611);
set_bus_id(_instance, _dev->get_bus_id());
if (_ms56xx_type == BARO_MS5837) {
_frontend.set_type(_instance, AP_Baro::BARO_TYPE_WATER);
}
// lower retries for run
_dev->set_retries(3);
_dev->get_semaphore()->give();
/* Request 100Hz update */
_dev->register_periodic_callback(10 * AP_USEC_PER_MSEC,
FUNCTOR_BIND_MEMBER(&AP_Baro_MS56XX::_timer, void));
return true;
}
uint16_t AP_Baro_MS56XX::_read_prom_word(uint8_t word)
{
const uint8_t reg = CMD_MS56XX_PROM + (word << 1);
uint8_t val[2];
if (!_dev->transfer(®, 1, val, sizeof(val))) {
return 0;
}
return (val[0] << 8) | val[1];
}
uint32_t AP_Baro_MS56XX::_read_adc()
{
uint8_t val[3];
if (!_dev->transfer(&CMD_MS56XX_READ_ADC, 1, val, sizeof(val))) {
return 0;
}
return (val[0] << 16) | (val[1] << 8) | val[2];
}
bool AP_Baro_MS56XX::_read_prom_5611(uint16_t prom[8])
{
/*
* MS5611-01BA datasheet, CYCLIC REDUNDANCY CHECK (CRC): "MS5611-01BA
* contains a PROM memory with 128-Bit. A 4-bit CRC has been implemented
* to check the data validity in memory."
*
* CRC field must me removed for CRC-4 calculation.
*/
bool all_zero = true;
for (uint8_t i = 0; i < 8; i++) {
prom[i] = _read_prom_word(i);
if (prom[i] != 0) {
all_zero = false;
}
}
if (all_zero) {
return false;
}
/* save the read crc */
const uint16_t crc_read = prom[7] & 0xf;
/* remove CRC byte */
prom[7] &= 0xff00;
return crc_read == crc_crc4(prom);
}
bool AP_Baro_MS56XX::_read_prom_5637(uint16_t prom[8])
{
/*
* MS5637-02BA03 datasheet, CYCLIC REDUNDANCY CHECK (CRC): "MS5637
* contains a PROM memory with 112-Bit. A 4-bit CRC has been implemented
* to check the data validity in memory."
*
* 8th PROM word must be zeroed and CRC field removed for CRC-4
* calculation.
*/
bool all_zero = true;
for (uint8_t i = 0; i < 7; i++) {
prom[i] = _read_prom_word(i);
if (prom[i] != 0) {
all_zero = false;
}
}
if (all_zero) {
return false;
}
prom[7] = 0;
/* save the read crc */
const uint16_t crc_read = (prom[0] & 0xf000) >> 12;
/* remove CRC byte */
prom[0] &= ~0xf000;
return crc_read == crc_crc4(prom);
}
/*
* Read the sensor with a state machine
* We read one time temperature (state=0) and then 4 times pressure (states 1-4)
*
* Temperature is used to calculate the compensated pressure and doesn't vary
* as fast as pressure. Hence we reuse the same temperature for 4 samples of
* pressure.
*/
void AP_Baro_MS56XX::_timer(void)
{
uint8_t next_cmd;
uint8_t next_state;
uint32_t adc_val = _read_adc();
/*
* If read fails, re-initiate a read command for current state or we are
* stuck
*/
if (adc_val == 0) {
next_state = _state;
} else {
next_state = (_state + 1) % 5;
}
next_cmd = next_state == 0 ? ADDR_CMD_CONVERT_TEMPERATURE
: ADDR_CMD_CONVERT_PRESSURE;
if (!_dev->transfer(&next_cmd, 1, nullptr, 0)) {
return;
}
/* if we had a failed read we are all done */
if (adc_val == 0 || adc_val == 0xFFFFFF) {
// a failed read can mean the next returned value will be
// corrupt, we must discard it. This copes with MISO being
// pulled either high or low
_discard_next = true;
return;
}
if (_discard_next) {
_discard_next = false;
_state = next_state;
return;
}
WITH_SEMAPHORE(_sem);
if (_state == 0) {
_update_and_wrap_accumulator(&_accum.s_D2, adc_val,
&_accum.d2_count, 32);
} else if (pressure_ok(adc_val)) {
_update_and_wrap_accumulator(&_accum.s_D1, adc_val,
&_accum.d1_count, 128);
}
_state = next_state;
}
void AP_Baro_MS56XX::_update_and_wrap_accumulator(uint32_t *accum, uint32_t val,
uint8_t *count, uint8_t max_count)
{
*accum += val;
*count += 1;
if (*count == max_count) {
*count = max_count / 2;
*accum = *accum / 2;
}
}
void AP_Baro_MS56XX::update()
{
uint32_t sD1, sD2;
uint8_t d1count, d2count;
{
WITH_SEMAPHORE(_sem);
if (_accum.d1_count == 0) {
return;
}
sD1 = _accum.s_D1;
sD2 = _accum.s_D2;
d1count = _accum.d1_count;
d2count = _accum.d2_count;
memset(&_accum, 0, sizeof(_accum));
}
if (d1count != 0) {
_D1 = ((float)sD1) / d1count;
}
if (d2count != 0) {
_D2 = ((float)sD2) / d2count;
}
switch (_ms56xx_type) {
case BARO_MS5607:
_calculate_5607();
break;
case BARO_MS5611:
_calculate_5611();
break;
case BARO_MS5637:
_calculate_5637();
break;
case BARO_MS5837:
_calculate_5837();
}
}
// Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100).
void AP_Baro_MS56XX::_calculate_5611()
{
float dT;
float TEMP;
float OFF;
float SENS;
// we do the calculations using floating point allows us to take advantage
// of the averaging of D1 and D1 over multiple samples, giving us more
// precision
dT = _D2-(((uint32_t)_cal_reg.c5)<<8);
TEMP = (dT * _cal_reg.c6)/8388608;
OFF = _cal_reg.c2 * 65536.0f + (_cal_reg.c4 * dT) / 128;
SENS = _cal_reg.c1 * 32768.0f + (_cal_reg.c3 * dT) / 256;
TEMP += 2000;
if (TEMP < 2000) {
// second order temperature compensation when under 20 degrees C
float T2 = (dT*dT) / 0x80000000;
float Aux = sq(TEMP-2000.0);
float OFF2 = 2.5f*Aux;
float SENS2 = 1.25f*Aux;
if (TEMP < -1500) {
// extra compensation for temperatures below -15C
OFF2 += 7 * sq(TEMP+1500);
SENS2 += sq(TEMP+1500) * 11.0*0.5;
}
TEMP = TEMP - T2;
OFF = OFF - OFF2;
SENS = SENS - SENS2;
}
float pressure = (_D1*SENS/2097152 - OFF)/32768;
float temperature = TEMP * 0.01f;
_copy_to_frontend(_instance, pressure, temperature);
}
// Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100).
void AP_Baro_MS56XX::_calculate_5607()
{
float dT;
float TEMP;
float OFF;
float SENS;
// we do the calculations using floating point allows us to take advantage
// of the averaging of D1 and D1 over multiple samples, giving us more
// precision
dT = _D2-(((uint32_t)_cal_reg.c5)<<8);
TEMP = (dT * _cal_reg.c6)/8388608;
OFF = _cal_reg.c2 * 131072.0f + (_cal_reg.c4 * dT) / 64;
SENS = _cal_reg.c1 * 65536.0f + (_cal_reg.c3 * dT) / 128;
TEMP += 2000;
if (TEMP < 2000) {
// second order temperature compensation when under 20 degrees C
float T2 = (dT*dT) / 0x80000000;
float Aux = sq(TEMP-2000);
float OFF2 = 61.0f*Aux/16.0f;
float SENS2 = 2.0f*Aux;
if (TEMP < -1500) {
OFF2 += 15 * sq(TEMP+1500);
SENS2 += 8 * sq(TEMP+1500);
}
TEMP = TEMP - T2;
OFF = OFF - OFF2;
SENS = SENS - SENS2;
}
float pressure = (_D1*SENS/2097152 - OFF)/32768;
float temperature = TEMP * 0.01f;
_copy_to_frontend(_instance, pressure, temperature);
}
// Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100).
void AP_Baro_MS56XX::_calculate_5637()
{
int32_t dT, TEMP;
int64_t OFF, SENS;
int32_t raw_pressure = _D1;
int32_t raw_temperature = _D2;
dT = raw_temperature - (((uint32_t)_cal_reg.c5) << 8);
TEMP = 2000 + ((int64_t)dT * (int64_t)_cal_reg.c6) / 8388608;
OFF = (int64_t)_cal_reg.c2 * (int64_t)131072 + ((int64_t)_cal_reg.c4 * (int64_t)dT) / (int64_t)64;
SENS = (int64_t)_cal_reg.c1 * (int64_t)65536 + ((int64_t)_cal_reg.c3 * (int64_t)dT) / (int64_t)128;
if (TEMP < 2000) {
// second order temperature compensation when under 20 degrees C
int32_t T2 = ((int64_t)3 * ((int64_t)dT * (int64_t)dT) / (int64_t)8589934592);
int64_t aux = (TEMP - 2000) * (TEMP - 2000);
int64_t OFF2 = 61 * aux / 16;
int64_t SENS2 = 29 * aux / 16;
if (TEMP < -1500) {
OFF2 += 17 * sq(TEMP+1500);
SENS2 += 9 * sq(TEMP+1500);
}
TEMP = TEMP - T2;
OFF = OFF - OFF2;
SENS = SENS - SENS2;
}
int32_t pressure = ((int64_t)raw_pressure * SENS / (int64_t)2097152 - OFF) / (int64_t)32768;
float temperature = TEMP * 0.01f;
_copy_to_frontend(_instance, (float)pressure, temperature);
}
// Calculate Temperature and compensated Pressure in real units (Celsius degrees*100, mbar*100).
void AP_Baro_MS56XX::_calculate_5837()
{
int32_t dT, TEMP;
int64_t OFF, SENS;
int32_t raw_pressure = _D1;
int32_t raw_temperature = _D2;
// note that MS5837 has no compensation for temperatures below -15C in the datasheet
dT = raw_temperature - (((uint32_t)_cal_reg.c5) << 8);
TEMP = 2000 + ((int64_t)dT * (int64_t)_cal_reg.c6) / 8388608;
OFF = (int64_t)_cal_reg.c2 * (int64_t)65536 + ((int64_t)_cal_reg.c4 * (int64_t)dT) / (int64_t)128;
SENS = (int64_t)_cal_reg.c1 * (int64_t)32768 + ((int64_t)_cal_reg.c3 * (int64_t)dT) / (int64_t)256;
if (TEMP < 2000) {
// second order temperature compensation when under 20 degrees C
int32_t T2 = ((int64_t)3 * ((int64_t)dT * (int64_t)dT) / (int64_t)8589934592);
int64_t aux = (TEMP - 2000) * (TEMP - 2000);
int64_t OFF2 = 3 * aux / 2;
int64_t SENS2 = 5 * aux / 8;
TEMP = TEMP - T2;
OFF = OFF - OFF2;
SENS = SENS - SENS2;
}
int32_t pressure = ((int64_t)raw_pressure * SENS / (int64_t)2097152 - OFF) / (int64_t)8192;
pressure = pressure * 10; // MS5837 only reports to 0.1 mbar
float temperature = TEMP * 0.01f;