It is given by Rd + (Rv - Rd) *qv = Rd *(1-qv) + Rv * qv instead of, say, Rd *(1 - qv - ql - qi) + Rv *qv.
Noted while attempting to use water loading in consistent coupling with the thermal bubble test case, but also mentioned by @mahf708 in E3SM-Project/scream#2813 .
The text was updated successfully, but these errors were encountered:
... is not set for water loading.
It is given by Rd + (Rv - Rd) *qv = Rd *(1-qv) + Rv * qv instead of, say, Rd *(1 - qv - ql - qi) + Rv *qv.
Noted while attempting to use water loading in consistent coupling with the thermal bubble test case, but also mentioned by @mahf708 in E3SM-Project/scream#2813 .