Notifications
You must be signed in to change notification settings - Fork 2
/
lineOperations.py
125 lines (105 loc) · 3.15 KB
/
lineOperations.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
# -*- coding: utf-8 -*-
from builtins import str
from qgis.core import QgsMessageLog
def renameVoltage(LVCodein): #Para monofasicos, tension L-N, para trifasicos tension L-L
LVCodein = str(LVCodein)
if LVCodein == '20':
LVCode = {'LN':0.12, 'LL':0.208}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '30':
LVCode = {'LN':0.12, 'LL':0.24}
conns = '.1.2'
cantFases = '1'
config = 'wye' #split Phase
elif LVCodein == '35':
LVCode = {'LN':0.254, 'LL':0.44}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '40':
LVCode = {'LN':0.240, 'LL':0.48}
conns = '.1.2.3'
cantFases = '3'
config = 'delta' # Esto es 4D
elif LVCodein == '50':
LVCode = {'LN':0.277, 'LL':0.48}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '60':
LVCode = {'LN':0.48, 'LL':0.48} #Conexión delta 3 conductores
conns = '.1.2.3'
cantFases = '3'
config = 'delta'
elif LVCodein == '70':
LVCode = {'LN':0.24, 'LL':0.416}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '80':
LVCode = {'LN': 2.4, 'LL': 2.4}
conns = '.1.2.3'
cantFases = '3'
config = 'delta'
elif LVCodein == '110':
LVCode = {'LN': 4.16, 'LL': 4.16}
conns = '.1.2.3'
cantFases = '3'
config = 'delta'
elif LVCodein == '120':
LVCode = {'LN': 2.4, 'LL': 4.16}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '150':
LVCode = {'LN': 7.20, 'LL': 7.20}
conns = '.1.2.3'
cantFases = '3'
config = 'delta'
elif LVCodein == '160':
LVCode = {'LN': 4.16, 'LL': 7.20}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '210':
LVCode = {'LN': 7.22, 'LL': 12.5}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '230':
LVCode = {'LN':7.62, 'LL':13.2}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '260':
LVCode = {'LN': 13.8, 'LL': 13.8}
conns = '.1.2.3'
cantFases = '3'
config = 'delta'
elif LVCodein == '270':
LVCode = {'LN':7.9674, 'LL':13.8}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '340':
LVCode = {'LN':14.38, 'LL':24.9}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
elif LVCodein == '380':
LVCode = {'LN':19.9186, 'LL':34.5}
conns = '.1.2.3'
cantFases = '3'
config = 'wye'
else:
LVCode = {'LN':'NONE', 'LL':'NONE'}
conns = 'NONE'
cantFases = 'NONE'
config = 'NONE'
aviso= u'La tensión de operación ' + str(LVCodein) + ' es desconocida.'
QgsMessageLog.logMessage(aviso, u'Tensiones')
voltageCodes={'LVCode': LVCode, 'conns': conns,
'cantFases': cantFases, 'config': config}
return voltageCodes