It appears that the hotend heater and bed heater sensors are reversed on the info for the Cheetah v2.0 board #1

Open
iwascurious opened this issue Apr 11, 2022 · 0 comments

Comments

@iwascurious
Copy link

Recent picture graph shows to plug T-End and T-Bed in the opposite ports which will result in an error found during initial startup. example here https://github.com/FYSETC/FYSETC-Voron-0/blob/main/FYSETC_VORON0.1_rev1.1_Wiring.png

On Fysetc Wiki for the Cheetah v2.0 the Pin mapping is also reflecting the incorrect info example here https://wiki.fysetc.com/Cheetah_Board_V20/#43-pin-definition

I fixed my issue by switching the T-End and T-Bed sensor connectors on the board. Leaving the same pin mapping as stated in the Fysetc Wiki Cheetah v2.0 list in my Klipper printer.cfg. I can confirm that on my Cheetah v2.0 board the

Temperature
TE0 | PC4 | 24 |  
TB | PC5 | 25

are opposite from what is stated on the board as of the time I posted this.