- Type: CAN Standard
- ID: 0x3B4
- DLC: 8
- Tx method: cycle
- Cycle time: 5s
Signal | Start bit | Length | Order | Value type | Factor | Offset | Unit |
---|---|---|---|---|---|---|---|
U_BT | 0 | 12 | Intel | Unsigned | 0.015 | 0 | V |
ST_BTSW | 12 | 2 | Intel | Unsigned | 1 | 0 | |
ENG_ST | 16 | 4 | Intel | Unsigned | 1 | 0 | |
ST_SWO_KL_30 | 30 | 2 | Intel | Unsigned | 1 | 0 | |
SDWN_COU_BTSW | 32 | 8 | Intel | Unsigned | 1 | 0 |
- ST_BTSW: status battery main switch
Value | Description |
---|---|
0x00 | battery switch closed |
0x1 | battery switch opens in 5s |
0x2 | signal invalid |
- ST_SWO_KL_30
Value | Description |
---|---|
0x00 | reserved |
0x1 | no shutdown by PM done |
0x2 | shutdown by PM done |
0x3 | signal invalid |
Message example:
- 0x3B4 8 D9 03 00 53 FE 18 32 08
- U_BT: 14.7750V
- ST_BTSW: 0
- ENG_ST: 0
- ST_SWO_KL_30: 1
- SDWN_COU_BTSW: 254s