The weight of R101 provided #12

Open
dmy1997 opened this issue Jan 16, 2024 · 1 comment
Open

The weight of R101 provided #12

dmy1997 opened this issue Jan 16, 2024 · 1 comment

Comments

@dmy1997
Copy link

dmy1997 commented Jan 16, 2024

In the paper, R101 is frozen in stem and ResNet1 block. However, I print the weights and they are different from the in1k R101 model. Have they finetuned?

@Jaraxxus-Me
Copy link
Owner

Hi,
This is an interesting finding.
I was using Detectron2 interface when doing the training, you can see it in the config file, here, I used "freeze at: 1", this means the ResNet1 block should be fixed according to my understanding.
Have you tried to re-train using my code and check the weights?