Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

ParaMETEO hardware: fitting DB-9 connector #11

Open
SP8EBC opened this issue Jul 13, 2023 · 0 comments
Open

ParaMETEO hardware: fitting DB-9 connector #11

SP8EBC opened this issue Jul 13, 2023 · 0 comments
Assignees

Comments

@SP8EBC
Copy link
Owner

SP8EBC commented Jul 13, 2023

It's hard to believe but there is a problem with mechanical compatibility between two Amphenol connectors.

DE09P065TXLF - DB9 male soldered on cable
LD09S24A4GV00LF - DB9 female straight on PCB.

male plug cannot be pull completely into a connector. For some reason there will be no contact in between. The solution is to put two 1mm washers between male plug screw and a peg in the PCB female connector.

@SP8EBC SP8EBC self-assigned this Jul 13, 2023