First character sent to the UART is smashed #30

Closed
BrunoLevy opened this issue Jan 17, 2021 · 2 comments
Closed

First character sent to the UART is smashed #30

BrunoLevy opened this issue Jan 17, 2021 · 2 comments
Labels
bug Something isn't working

Comments

@BrunoLevy
Copy link
Owner

No description provided.

@BrunoLevy BrunoLevy added the bug Something isn't working label Jan 17, 2021
@BrunoLevy
Copy link
Owner Author

Found out: in uart verilog, send_pattern should be initialized to 1 so that first value of the stop bit is correct.

@Mecrisp
Copy link
Contributor

Mecrisp commented Jan 27, 2021

I confirm that send_pattern = 1; solves the smashed character. However, the short Reset delay sometimes also produced wrong characters directly after boot, so I reverted to reg [7:0] reset_cnt = 0;