Until now, the temperature is prescribed at the bottom of the domain. This should be changed to a Neumann condition (prescribed heat flux) to ensure correct results even with low ice thickness.
The text was updated successfully, but these errors were encountered:
Until now, the temperature is prescribed at the bottom of the domain. This should be changed to a Neumann condition (prescribed heat flux) to ensure correct results even with low ice thickness.