I cant see any difference in the important parameters. Maybe if you enable Domoticz debug log and see what kind of devices it creates for you, it will help. Shelly Dimmer: Shelly Plus1PM: |
Sorry, i forget to tell you... for my Shelly Dimmer, i use the old plug-in Shelly MQTT for Domoticz... |
The old plugin creates devices for itself, but Domoticz MQTT AD hardware creates the devices in this case. |
Thanks... But i think is not a problem from Domoticz... In SQL (DeviceStatus) my Shelly Plus 1 PM is Type 248 and subtype 1 and option is "1;" |
MQTT config documentation for "Sensor" type: I see 3 point where we can tell Domoticz which kind of sensor we want: And these are the standard device types: Maybe you can try alter class or state_class to "total_increasing" but as i see in the Domoticz source code, it is only watching for the unit of measurement and creates a specific kind of device if it is "W". |
Ok many thanks, maybe it's the solution... I have changed the template ... in "mqtt_templates_gen2.txt" ans i have deleted in domoticz the device... and i haved exec "python3 shellyteacher4domo.py" is it good ? (new device, but same problem and i think it's not with the new template) |
The process is good. You can enable debug in setup.py to see the sent mqtt payloads.. but do not forget to disable debug, after checking. |
243/29 is a General/Electric (Instant+Counter) device which has a unit of kWh this is created by Domoticz when unit is "kWh" .. and only this kind of device has the option for "Compute". 248/1 is a Usage / Electric device is created by Domoticz MQTT AD when unit is "W" Most of Shelly devices returns watt-minutes, which needs to be translated to kwh first, but it is currently not supported in Domozicz, see issue: |
Hi,
Sorry for my english, but i can't computed energy for my shelly plus 1
and this is my Shelly Dimmer and i have the possibility to computed energy
Did you have an idea?
Many Thanks