Notifications
You must be signed in to change notification settings - Fork 54
/
Kconfig
233 lines (203 loc) · 9 KB
/
Kconfig
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
menu "Modbus configuration"
config FMB_COMM_MODE_TCP_EN
bool "Enable Modbus stack support for TCP communication mode"
default y
help
Enable Modbus TCP option for stack.
config FMB_TCP_PORT_DEFAULT
int "Modbus TCP port number"
range 0 65535
default 502
depends on FMB_COMM_MODE_TCP_EN
help
Modbus default port number used by Modbus TCP stack
config FMB_TCP_PORT_MAX_CONN
int "Maximum allowed connections for TCP stack"
range 1 8
default 5
depends on FMB_COMM_MODE_TCP_EN
help
Maximum allowed connections number for Modbus TCP stack.
This is used by Modbus master and slave port layer to establish connections.
This parameter may decrease performance of Modbus stack and can cause
increasing of processing time (increase only if absolutely necessary).
config FMB_TCP_CONNECTION_TOUT_SEC
int "Modbus TCP connection timeout"
range 1 3600
default 20
depends on FMB_COMM_MODE_TCP_EN
help
Modbus TCP connection timeout in seconds.
Once expired the current connection with the client will be closed
and Modbus slave will be waiting for new connection to accept.
config FMB_TCP_UID_ENABLED
bool "Modbus TCP enable UID (Unit Identifier) support"
default n
depends on FMB_COMM_MODE_TCP_EN
help
If this option is set the Modbus stack uses UID (Unit Identifier) field in MBAP frame.
Else the UID is ignored by master and slave.
config FMB_COMM_MODE_RTU_EN
bool "Enable Modbus stack support for RTU mode"
default y
help
Enable RTU Modbus communication mode option for Modbus serial stack.
config FMB_COMM_MODE_ASCII_EN
bool "Enable Modbus stack support for ASCII mode"
default y
help
Enable ASCII Modbus communication mode option for Modbus serial stack.
config FMB_MASTER_TIMEOUT_MS_RESPOND
int "Slave respond timeout (Milliseconds)"
default 3000
range 150 15000
help
If master sends a frame which is not broadcast, it has to wait sometime for slave response.
if slave is not respond in this time, the master will process timeout error.
config FMB_MASTER_DELAY_MS_CONVERT
int "Slave conversion delay (Milliseconds)"
default 200
range 150 2000
help
If master sends a broadcast frame, it has to wait conversion time to delay,
then master can send next frame.
config FMB_QUEUE_LENGTH
int "Modbus serial task queue length"
range 0 200
default 20
help
Modbus serial driver queue length. It is used by event queue task.
See the serial driver API for more information.
config FMB_PORT_TASK_STACK_SIZE
int "Modbus port task stack size"
range 2048 8192
default 4096
help
Modbus port task stack size for rx/tx event processing.
It may be adjusted when debugging is enabled (for example).
config FMB_SERIAL_BUF_SIZE
int "Modbus serial task RX/TX buffer size"
range 0 2048
default 256
help
Modbus serial task RX and TX buffer size for UART driver initialization.
This buffer is used for modbus frame transfer. The Modbus protocol maximum
frame size is 256 bytes. Bigger size can be used for non standard implementations.
config FMB_SERIAL_ASCII_BITS_PER_SYMB
int "Number of data bits per ASCII character"
default 8
range 7 8
depends on FMB_COMM_MODE_ASCII_EN
help
This option defines the number of data bits per ASCII character.
config FMB_ASCII_TIMEOUT_WAIT_BEFORE_SEND_MS
int "Wait before send for ASCII communication mode (ms)"
default 0
range 0 1000
depends on FMB_COMM_MODE_ASCII_EN
help
This option defines timeout before slave sends the response in ASCII communication mode.
This allows to work with slow masters. Zero means delay before send is disabled.
config FMB_SERIAL_ASCII_TIMEOUT_RESPOND_MS
int "Response timeout for ASCII communication mode (ms)"
default 1000
range 200 5000
depends on FMB_COMM_MODE_ASCII_EN
help
This option defines response timeout of slave in milliseconds for ASCII communication mode.
Thus the timeout will expire and allow the master program to handle the error.
config FMB_PORT_TASK_PRIO
int "Modbus port task priority"
range 3 23
default 10
help
Modbus port data processing task priority.
The priority of Modbus controller task is equal to (CONFIG_FMB_PORT_TASK_PRIO - 1).
choice FMB_PORT_TASK_AFFINITY
prompt "Modbus task affinity"
default FMB_PORT_TASK_AFFINITY_CPU0
depends on !FREERTOS_UNICORE
help
Allows setting the core affinity of the Modbus controller task, i.e. whether the task is pinned to
particular CPU, or allowed to run on any CPU.
config FMB_PORT_TASK_AFFINITY_NO_AFFINITY
bool "No affinity"
config FMB_PORT_TASK_AFFINITY_CPU0
bool "CPU0"
config FMB_PORT_TASK_AFFINITY_CPU1
bool "CPU1"
endchoice
config FMB_PORT_TASK_AFFINITY
hex
default FREERTOS_NO_AFFINITY if FMB_PORT_TASK_AFFINITY_NO_AFFINITY || FREERTOS_UNICORE
default 0x0 if FMB_PORT_TASK_AFFINITY_CPU0
default 0x1 if FMB_PORT_TASK_AFFINITY_CPU1
config FMB_CONTROLLER_SLAVE_ID_SUPPORT
bool "Modbus controller slave ID support"
default y
help
Modbus slave ID support enable.
When enabled the Modbus <Report Slave ID> command is supported by stack.
config FMB_CONTROLLER_SLAVE_ID
hex "Modbus controller slave ID"
range 0 4294967295
default 0x00112233
depends on FMB_CONTROLLER_SLAVE_ID_SUPPORT
help
Modbus slave ID value to identify modbus device
in the network using <Report Slave ID> command.
Most significant byte of ID is used as short device ID and
other three bytes used as long ID.
config FMB_CONTROLLER_NOTIFY_TIMEOUT
int "Modbus controller notification timeout (ms)"
range 0 200
default 20
help
Modbus controller notification timeout in milliseconds.
This timeout is used to send notification about accessed parameters.
config FMB_CONTROLLER_NOTIFY_QUEUE_SIZE
int "Modbus controller notification queue size"
range 0 200
default 20
help
Modbus controller notification queue size.
The notification queue is used to get information about accessed parameters.
config FMB_CONTROLLER_STACK_SIZE
int "Modbus controller stack size"
range 0 8192
default 4096
help
Modbus controller task stack size. The Stack size may be adjusted when
debug mode is used which requires more stack size (for example).
config FMB_EVENT_QUEUE_TIMEOUT
int "Modbus stack event queue timeout (ms)"
range 0 500
default 20
help
Modbus stack event queue timeout in milliseconds. This may help to optimize
Modbus stack event processing time.
config FMB_TIMER_PORT_ENABLED
bool "Modbus stack use timer for 3.5T symbol time measurement"
default n
help
If this option is set the Modbus stack uses timer for T3.5 time measurement.
Else the internal UART TOUT timeout is used for 3.5T symbol time measurement.
config FMB_TIMER_USE_ISR_DISPATCH_METHOD
bool "Modbus timer uses ISR dispatch method"
default n
select ESP_TIMER_SUPPORTS_ISR_DISPATCH_METHOD
select UART_ISR_IN_IRAM
help
If this option is set the Modbus stack uses ISR dispatch method
to send timeout events from the callback function called from ISR.
This option has dependency with the UART_ISR_IN_IRAM option which places UART interrupt
handler into IRAM to prevent delays related to processing of UART events.
config FMB_EXT_TYPE_SUPPORT
bool "Modbus uses extended types to support third party devices"
default n
help
If this option is set the Modbus stack supports extended list of types
in data dictionary and conversion API to work with the extended types
otherwise the only legacy types are supported. The extended types include
integer, float, double types with different endianness and size.
endmenu