PV mode turns into fast mode, ignoring available surplus #7362

Closed
GrimmiMeloni opened this issue Apr 11, 2023 · 7 comments
Closed

PV mode turns into fast mode, ignoring available surplus #7362

GrimmiMeloni opened this issue Apr 11, 2023 · 7 comments
Labels
question Rather clarification than issue

Comments

@GrimmiMeloni
Copy link
Collaborator

Describe the bug

I just observed the following.
Charing in PV mode, with 1 phase.
Surplus was around 6kW.
Phase switching timer expired, 1p to 3p switch happened.
After phase switch, charging goes all the way to 11kW and stays there, effectively turning this into fastmode.
I would expect the charging power to be closer to the 6kW surplus

Steps to reproduce

  1. Charge with 1p
  2. Switch to 3p via phase scale timer
  3. charging power goes to 11kW, instead of expected surplus only.

Configuration details

# open evcc at http://evcc.local:7070
network:
  schema: http
  host: evcc.local # .local suffix announces the hostname on MDNS
  port: 7070

log: debug
levels:
  cache: error
  easee: debug
  enyaq: debug

# unique installation id
plant: xxx
sponsortoken: xxx

interval: 10s # control cycle interval

meters:
- type: template
  template: tesla-powerwall 
  usage: grid  
  host: 192.168.3.38  
  password: xxx  
  name: grid1
- type: template
  template: tesla-powerwall 
  usage: pv  
  host: 192.168.3.38  
  password: xxx  
  name: pv2
- type: template
  template: tesla-powerwall 
  usage: battery  
  host: 192.168.3.38  
  password: xxx  
  name: battery3

site:
  title: Zu Hause
  meters:
    grid: grid1
    pvs:
    - pv2
    batteries:
    - battery3
  residualPower: 100 # im PV modus wird 100W für Laden des Hausakkus übrig gelassen, damit Regelkreise Tesla/EVCC nicht konkurrieren
  prioritySoc: 70 # Hausbatterie bekommt bis zum SoC Priorität beim laden
  bufferSoc: 80 # bis zu diesem SoC wird Batterie zur kurzfristigen Überbrückung bei PV Ladung genutzt

chargers:
  - name: Easee
    type: template
    template: easee
    user: xxx
    password: xxx
    charger: xxx

loadpoints:
  - title: Carport # display name for UI
    charger: Easee
    mode: off
    resetOnDisconnect: true

tariffs:
  currency: EUR # (default EUR)
  grid:
    type: fixed
    price: 0.3796 # [currency]/kWh

  feedin:
    type: fixed
    price: 0.082 # [currency]/kWh

vehicles:
  - name: Enyaq
    type: template
    template: enyaq
    title: Enyaq
    user: xxx
    password: xxx
    vin: xxx # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind # Optional
    capacity: 82 # Akku-Kapazität in kWh # Optional 
    mode: pv #im Winter besser auf "now"

# mqtt message broker
mqtt:
  broker: xxx
  topic: evcc # root topic for publishing, set empty to disable publishing
  # clientid: foo
  # user:
  # password:

Log details

[site  ] DEBUG 2023/04/11 14:57:30 ----
[lp-1  ] DEBUG 2023/04/11 14:57:30 charge power: 0W
[site  ] DEBUG 2023/04/11 14:57:30 pv power: 2723W
[site  ] DEBUG 2023/04/11 14:57:30 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:57:30 battery power: 0W
[site  ] DEBUG 2023/04/11 14:57:30 grid power: -1969W
[site  ] DEBUG 2023/04/11 14:57:30 site power: -1869W
[lp-1  ] DEBUG 2023/04/11 14:57:30 charge currents: [0 0 0]A
[lp-1  ] DEBUG 2023/04/11 14:57:30 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:57:30 charger status: A
[site  ] DEBUG 2023/04/11 14:57:40 ----
[lp-1  ] DEBUG 2023/04/11 14:57:40 charge power: 182W
[site  ] DEBUG 2023/04/11 14:57:40 pv power: 3442W
[site  ] DEBUG 2023/04/11 14:57:40 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:57:40 battery power: 0W
[site  ] DEBUG 2023/04/11 14:57:40 grid power: -1218W
[site  ] DEBUG 2023/04/11 14:57:40 site power: -1118W
[lp-1  ] DEBUG 2023/04/11 14:57:40 charge currents: [6.02 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:57:40 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:57:40 charger status: C
[lp-1  ] INFO 2023/04/11 14:57:40 car connected
[lp-1  ] DEBUG 2023/04/11 14:57:40 vehicle api refresh
[lp-1  ] DEBUG 2023/04/11 14:57:40 pv timer elapse
[lp-1  ] DEBUG 2023/04/11 14:57:40 pv timer inactive
[lp-1  ] DEBUG 2023/04/11 14:57:40 charger: guard elapse
[lp-1  ] DEBUG 2023/04/11 14:57:40 guard timer inactive
[lp-1  ] DEBUG 2023/04/11 14:57:40 charge meter total import: 788.745kWh
[lp-1  ] INFO 2023/04/11 14:57:40 start charging ->
[lp-1  ] DEBUG 2023/04/11 14:57:40 wake-up timer: stop
[main  ] DEBUG 2023/04/11 14:57:43 vehicle status: C (Enyaq)
[lp-1  ] INFO 2023/04/11 14:57:43 vehicle updated: unknown -> Enyaq
[lp-1  ] DEBUG 2023/04/11 14:57:43 set charge mode: pv
[lp-1  ] DEBUG 2023/04/11 14:57:43 vehicle status: C
[lp-1  ] DEBUG 2023/04/11 14:57:43 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:57:44 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:57:44 vehicle range: 371km
[lp-1  ] WARN 2023/04/11 14:57:44 charger out of sync: expected disabled, got enabled
[site  ] DEBUG 2023/04/11 14:57:44 ----
[lp-1  ] DEBUG 2023/04/11 14:57:44 charge power: 1486W
[site  ] DEBUG 2023/04/11 14:57:44 telemetry: charge: Δ11/11Wh @ 182W
[site  ] DEBUG 2023/04/11 14:57:44 pv power: 4189W
[site  ] DEBUG 2023/04/11 14:57:44 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:57:44 battery power: 0W
[site  ] DEBUG 2023/04/11 14:57:44 grid power: -2040W
[site  ] DEBUG 2023/04/11 14:57:44 site power: -1940W
[lp-1  ] DEBUG 2023/04/11 14:57:45 vehicle odometer: 3499km
[lp-1  ] DEBUG 2023/04/11 14:57:45 charge currents: [6.02 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:57:45 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:57:45 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:57:46 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:57:46 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:57:46 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:57:46 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:57:46 vehicle range: 371km
[lp-1  ] WARN 2023/04/11 14:57:46 charger logic error: disabled but charging
[lp-1  ] DEBUG 2023/04/11 14:57:46 pv charge current: 14.4A = 6A + 8.43A (-1940W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:57:46 site power -1940W <= 0W enable threshold
[lp-1  ] DEBUG 2023/04/11 14:57:46 pv enable in 0s
[lp-1  ] DEBUG 2023/04/11 14:57:46 pv enable timer elapsed
[lp-1  ] DEBUG 2023/04/11 14:57:46 charger enable
[lp-1  ] DEBUG 2023/04/11 14:57:46 wake-up timer: start
[site  ] DEBUG 2023/04/11 14:57:50 ----
[lp-1  ] DEBUG 2023/04/11 14:57:50 charge power: 0W
[site  ] DEBUG 2023/04/11 14:57:50 pv power: 5630W
[site  ] DEBUG 2023/04/11 14:57:50 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:57:50 battery power: -10W
[site  ] DEBUG 2023/04/11 14:57:50 grid power: -4871W
[site  ] DEBUG 2023/04/11 14:57:50 site power: -4781W
[lp-1  ] DEBUG 2023/04/11 14:57:50 charge currents: [0.009 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:57:50 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:57:50 charger status: B
[lp-1  ] INFO 2023/04/11 14:57:50 stop charging <-
[lp-1  ] DEBUG 2023/04/11 14:57:50 wake-up timer: start
[lp-1  ] DEBUG 2023/04/11 14:57:50 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:57:51 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:57:51 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:57:51 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:57:51 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:57:51 available power 4781W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:57:51 start phase scale3p timer
[lp-1  ] DEBUG 2023/04/11 14:57:51 phase scale3p in 1m0s
[lp-1  ] DEBUG 2023/04/11 14:57:51 pv charge current: 20.8A = 0A + 20.8A (-4781W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:57:51 pv timer reset
[lp-1  ] DEBUG 2023/04/11 14:57:51 pv timer inactive
[lp-1  ] DEBUG 2023/04/11 14:57:51 max charge current: 16A
[site  ] DEBUG 2023/04/11 14:58:00 ----
[lp-1  ] DEBUG 2023/04/11 14:58:00 charge power: 1486W
[site  ] DEBUG 2023/04/11 14:58:00 pv power: 5566W
[site  ] DEBUG 2023/04/11 14:58:00 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:00 battery power: 0W
[site  ] DEBUG 2023/04/11 14:58:00 grid power: -3353W
[site  ] DEBUG 2023/04/11 14:58:00 site power: -3253W
[lp-1  ] DEBUG 2023/04/11 14:58:00 charge currents: [4.11 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:00 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:00 charger status: C
[lp-1  ] INFO 2023/04/11 14:58:00 start charging ->
[lp-1  ] DEBUG 2023/04/11 14:58:00 wake-up timer: stop
[lp-1  ] DEBUG 2023/04/11 14:58:00 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:00 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:00 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:00 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:00 available power 4739W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:58:00 phase scale3p in 51s
[lp-1  ] DEBUG 2023/04/11 14:58:00 pv charge current: 20.2A = 6.11A + 14.1A (-3253W @ 1p)
[site  ] DEBUG 2023/04/11 14:58:10 ----
[lp-1  ] DEBUG 2023/04/11 14:58:10 charge power: 1486W
[site  ] DEBUG 2023/04/11 14:58:10 pv power: 2875W
[site  ] DEBUG 2023/04/11 14:58:10 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:10 battery power: -10W
[site  ] DEBUG 2023/04/11 14:58:10 grid power: -678W
[site  ] DEBUG 2023/04/11 14:58:10 site power: -588W
[lp-1  ] DEBUG 2023/04/11 14:58:10 charge currents: [4.11 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:10 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:58:10 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:10 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:58:10 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:10 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:10 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:10 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:10 phase timer inactive
[lp-1  ] DEBUG 2023/04/11 14:58:10 pv charge current: 8.66A = 6.11A + 2.56A (-588W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:58:10 max charge current: 8A
[site  ] DEBUG 2023/04/11 14:58:20 ----
[lp-1  ] DEBUG 2023/04/11 14:58:20 charge power: 2870W
[site  ] DEBUG 2023/04/11 14:58:20 pv power: 2884W
[site  ] DEBUG 2023/04/11 14:58:20 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:20 battery power: 0W
[site  ] DEBUG 2023/04/11 14:58:20 grid power: -367W
[site  ] DEBUG 2023/04/11 14:58:20 site power: -267W
[lp-1  ] DEBUG 2023/04/11 14:58:20 charge currents: [7.61 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:20 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:58:20 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:20 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:58:20 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:20 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:20 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:20 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:20 pv charge current: 9.16A = 8A + 1.16A (-267W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:58:20 max charge current: 9A
[site  ] DEBUG 2023/04/11 14:58:20 telemetry: charge: Δ17/17Wh @ 2870W
[site  ] DEBUG 2023/04/11 14:58:30 ----
[lp-1  ] DEBUG 2023/04/11 14:58:30 charge power: 1870W
[site  ] DEBUG 2023/04/11 14:58:30 pv power: 3420W
[site  ] DEBUG 2023/04/11 14:58:30 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:30 battery power: 0W
[site  ] DEBUG 2023/04/11 14:58:30 grid power: -877W
[site  ] DEBUG 2023/04/11 14:58:30 site power: -777W
[lp-1  ] DEBUG 2023/04/11 14:58:30 charge currents: [7.61 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:30 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:58:30 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:30 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:58:30 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:30 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:30 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:30 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:30 pv charge current: 12.4A = 9A + 3.38A (-777W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:58:30 max charge current: 12A
[site  ] DEBUG 2023/04/11 14:58:40 ----
[lp-1  ] DEBUG 2023/04/11 14:58:40 charge power: 1870W
[site  ] DEBUG 2023/04/11 14:58:40 pv power: 6828W
[site  ] DEBUG 2023/04/11 14:58:40 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:40 battery power: 0W
[site  ] DEBUG 2023/04/11 14:58:40 grid power: -4385W
[site  ] DEBUG 2023/04/11 14:58:40 site power: -4285W
[lp-1  ] DEBUG 2023/04/11 14:58:40 charge currents: [7.61 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:40 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:58:40 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:40 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:58:40 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:40 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:40 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:40 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:40 available power 6155W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:58:40 start phase scale3p timer
[lp-1  ] DEBUG 2023/04/11 14:58:40 phase scale3p in 1m0s
[lp-1  ] DEBUG 2023/04/11 14:58:40 pv charge current: 28.2A = 9.61A + 18.6A (-4285W @ 1p)
[lp-1  ] DEBUG 2023/04/11 14:58:40 max charge current: 16A
[site  ] DEBUG 2023/04/11 14:58:50 ----
[lp-1  ] DEBUG 2023/04/11 14:58:50 charge power: 2869W
[site  ] DEBUG 2023/04/11 14:58:50 pv power: 7033W
[site  ] DEBUG 2023/04/11 14:58:50 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:58:50 battery power: -10W
[site  ] DEBUG 2023/04/11 14:58:50 grid power: -3475W
[site  ] DEBUG 2023/04/11 14:58:50 site power: -3385W
[lp-1  ] DEBUG 2023/04/11 14:58:50 charge currents: [11.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:58:50 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:58:50 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:58:50 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:58:50 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:58:50 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:58:50 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:58:50 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:58:50 available power 6254W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:58:50 phase scale3p in 50s
[lp-1  ] DEBUG 2023/04/11 14:58:50 pv charge current: 28.4A = 13.6A + 14.7A (-3385W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:00 ----
[lp-1  ] DEBUG 2023/04/11 14:59:00 charge power: 2869W
[site  ] DEBUG 2023/04/11 14:59:00 pv power: 6853W
[site  ] DEBUG 2023/04/11 14:59:00 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:00 battery power: 0W
[site  ] DEBUG 2023/04/11 14:59:00 grid power: -3289W
[site  ] DEBUG 2023/04/11 14:59:00 site power: -3189W
[lp-1  ] DEBUG 2023/04/11 14:59:00 charge currents: [11.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:00 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:00 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:00 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:00 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:00 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:00 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:00 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:00 available power 6058W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:00 phase scale3p in 40s
[lp-1  ] DEBUG 2023/04/11 14:59:00 pv charge current: 27.5A = 13.6A + 13.9A (-3189W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:00 telemetry: charge: Δ26/26Wh @ 2869W
[site  ] DEBUG 2023/04/11 14:59:10 ----
[lp-1  ] DEBUG 2023/04/11 14:59:10 charge power: 2869W
[site  ] DEBUG 2023/04/11 14:59:10 pv power: 6889W
[site  ] DEBUG 2023/04/11 14:59:10 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:10 battery power: -30W
[site  ] DEBUG 2023/04/11 14:59:10 grid power: -3287W
[site  ] DEBUG 2023/04/11 14:59:10 site power: -3217W
[lp-1  ] DEBUG 2023/04/11 14:59:10 charge currents: [11.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:10 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:10 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:10 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:10 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:10 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:10 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:10 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:10 available power 6086W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:10 phase scale3p in 30s
[lp-1  ] DEBUG 2023/04/11 14:59:10 pv charge current: 27.6A = 13.6A + 14A (-3217W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:20 ----
[lp-1  ] DEBUG 2023/04/11 14:59:20 charge power: 3829W
[site  ] DEBUG 2023/04/11 14:59:20 pv power: 6934W
[site  ] DEBUG 2023/04/11 14:59:20 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:20 battery power: -10W
[site  ] DEBUG 2023/04/11 14:59:20 grid power: -2430W
[site  ] DEBUG 2023/04/11 14:59:20 site power: -2340W
[lp-1  ] DEBUG 2023/04/11 14:59:20 charge currents: [15.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:20 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:20 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:20 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:20 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:20 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:20 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:20 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:20 available power 6169W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:20 phase scale3p in 20s
[lp-1  ] DEBUG 2023/04/11 14:59:20 pv charge current: 26.2A = 16A + 10.2A (-2340W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:30 ----
[lp-1  ] DEBUG 2023/04/11 14:59:30 charge power: 3829W
[site  ] DEBUG 2023/04/11 14:59:30 pv power: 6899W
[site  ] DEBUG 2023/04/11 14:59:30 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:30 battery power: 0W
[site  ] DEBUG 2023/04/11 14:59:30 grid power: -2404W
[site  ] DEBUG 2023/04/11 14:59:30 site power: -2304W
[lp-1  ] DEBUG 2023/04/11 14:59:30 charge currents: [15.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:30 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:30 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:30 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:30 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:30 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:30 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:30 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:30 available power 6133W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:30 phase scale3p in 10s
[lp-1  ] DEBUG 2023/04/11 14:59:30 pv charge current: 26A = 16A + 10A (-2304W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:40 ----
[lp-1  ] DEBUG 2023/04/11 14:59:40 charge power: 3829W
[site  ] DEBUG 2023/04/11 14:59:40 pv power: 6852W
[site  ] DEBUG 2023/04/11 14:59:40 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:40 battery power: 10W
[site  ] DEBUG 2023/04/11 14:59:40 grid power: -2360W
[site  ] DEBUG 2023/04/11 14:59:40 site power: -2250W
[lp-1  ] DEBUG 2023/04/11 14:59:40 charge currents: [15.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:40 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:40 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:40 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:40 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:40 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:40 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:40 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:40 available power 6079W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:40 phase scale3p in 0s
[lp-1  ] DEBUG 2023/04/11 14:59:40 pv charge current: 25.8A = 16A + 9.78A (-2250W @ 1p)
[site  ] DEBUG 2023/04/11 14:59:40 telemetry: charge: Δ40/40Wh @ 3829W
[site  ] DEBUG 2023/04/11 14:59:50 ----
[lp-1  ] DEBUG 2023/04/11 14:59:50 charge power: 3829W
[site  ] DEBUG 2023/04/11 14:59:50 pv power: 6810W
[site  ] DEBUG 2023/04/11 14:59:50 battery soc: 100%
[site  ] DEBUG 2023/04/11 14:59:50 battery power: -10W
[site  ] DEBUG 2023/04/11 14:59:50 grid power: -2334W
[site  ] DEBUG 2023/04/11 14:59:50 site power: -2244W
[lp-1  ] DEBUG 2023/04/11 14:59:50 charge currents: [15.6 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 14:59:50 detected active phases: 1p
[lp-1  ] DEBUG 2023/04/11 14:59:50 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 14:59:50 charger status: C
[lp-1  ] DEBUG 2023/04/11 14:59:50 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 14:59:50 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 14:59:50 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 14:59:50 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 14:59:50 available power 6073W > 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 14:59:50 phase scale3p in 0s
[lp-1  ] DEBUG 2023/04/11 14:59:50 phase scale3p timer elapsed
[lp-1  ] DEBUG 2023/04/11 14:59:50 charger: guard elapse
[lp-1  ] DEBUG 2023/04/11 14:59:50 guard timer inactive
[lp-1  ] DEBUG 2023/04/11 14:59:50 charger disable
[lp-1  ] DEBUG 2023/04/11 14:59:50 wake-up timer: stop
[lp-1  ] DEBUG 2023/04/11 14:59:51 phase timer inactive
[lp-1  ] DEBUG 2023/04/11 14:59:51 pv timer elapse
[lp-1  ] DEBUG 2023/04/11 14:59:51 pv timer inactive
[lp-1  ] DEBUG 2023/04/11 14:59:51 charger: guard elapse
[lp-1  ] DEBUG 2023/04/11 14:59:51 guard timer inactive
[lp-1  ] DEBUG 2023/04/11 14:59:51 switched phases: 3p @ 6073W
[site  ] DEBUG 2023/04/11 15:00:00 ----
[lp-1  ] DEBUG 2023/04/11 15:00:00 charge power: 0W
[site  ] DEBUG 2023/04/11 15:00:00 pv power: 6799W
[site  ] DEBUG 2023/04/11 15:00:00 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:00 battery power: 0W
[site  ] DEBUG 2023/04/11 15:00:00 grid power: -6010W
[site  ] DEBUG 2023/04/11 15:00:00 site power: -5910W
[lp-1  ] DEBUG 2023/04/11 15:00:00 charge currents: [0.009 0.01 0.01]A
[lp-1  ] DEBUG 2023/04/11 15:00:00 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:00 charger status: B
[lp-1  ] INFO 2023/04/11 15:00:00 stop charging <-
[lp-1  ] DEBUG 2023/04/11 15:00:00 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:01 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:01 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:01 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:01 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:01 pv charge current: 8.57A = 0A + 8.57A (-5910W @ 3p)
[lp-1  ] DEBUG 2023/04/11 15:00:01 site power -5910W <= 0W enable threshold
[lp-1  ] DEBUG 2023/04/11 15:00:01 pv enable in 0s
[lp-1  ] DEBUG 2023/04/11 15:00:01 pv enable timer elapsed
[lp-1  ] DEBUG 2023/04/11 15:00:01 max charge current: 6A
[lp-1  ] DEBUG 2023/04/11 15:00:02 charger enable
[lp-1  ] DEBUG 2023/04/11 15:00:02 wake-up timer: start
[site  ] DEBUG 2023/04/11 15:00:10 ----
[lp-1  ] DEBUG 2023/04/11 15:00:10 charge power: 962W
[site  ] DEBUG 2023/04/11 15:00:10 pv power: 6784W
[site  ] DEBUG 2023/04/11 15:00:10 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:10 battery power: 4550W
[site  ] DEBUG 2023/04/11 15:00:10 grid power: 848W
[site  ] DEBUG 2023/04/11 15:00:10 site power: 5498W
[lp-1  ] DEBUG 2023/04/11 15:00:10 charge currents: [1.68 11.8 5.72]A
[lp-1  ] DEBUG 2023/04/11 15:00:10 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:10 charger status: C
[lp-1  ] INFO 2023/04/11 15:00:10 start charging ->
[lp-1  ] DEBUG 2023/04/11 15:00:10 wake-up timer: stop
[lp-1  ] DEBUG 2023/04/11 15:00:10 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:10 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:10 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:10 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:10 available power -4536W < 4140W min 3p threshold
[lp-1  ] DEBUG 2023/04/11 15:00:10 start phase scale1p timer
[lp-1  ] DEBUG 2023/04/11 15:00:10 phase scale1p in 3m0s
[lp-1  ] DEBUG 2023/04/11 15:00:10 pv charge current: 0A = 3.68A + -7.97A (5498W @ 3p)
[site  ] DEBUG 2023/04/11 15:00:20 ----
[lp-1  ] DEBUG 2023/04/11 15:00:20 charge power: 11532W
[site  ] DEBUG 2023/04/11 15:00:20 pv power: 6746W
[site  ] DEBUG 2023/04/11 15:00:20 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:20 battery power: 4530W
[site  ] DEBUG 2023/04/11 15:00:20 grid power: 917W
[site  ] DEBUG 2023/04/11 15:00:20 site power: 5547W
[lp-1  ] DEBUG 2023/04/11 15:00:20 charge currents: [15.8 16 16]A
[lp-1  ] DEBUG 2023/04/11 15:00:20 detected active phases: 3p
[lp-1  ] DEBUG 2023/04/11 15:00:20 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:20 charger status: C
[lp-1  ] DEBUG 2023/04/11 15:00:20 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:20 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:20 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:20 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:20 phase timer inactive
[lp-1  ] DEBUG 2023/04/11 15:00:20 pv charge current: 0A = 6A + -8.04A (5547W @ 3p)
[site  ] DEBUG 2023/04/11 15:00:20 telemetry: charge: Δ43/46Wh @ 11532W
[site  ] DEBUG 2023/04/11 15:00:30 ----
[lp-1  ] DEBUG 2023/04/11 15:00:30 charge power: 11532W
[site  ] DEBUG 2023/04/11 15:00:30 pv power: 6749W
[site  ] DEBUG 2023/04/11 15:00:30 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:30 battery power: 4550W
[site  ] DEBUG 2023/04/11 15:00:30 grid power: 944W
[site  ] DEBUG 2023/04/11 15:00:30 site power: 5594W
[lp-1  ] DEBUG 2023/04/11 15:00:30 charge currents: [15.8 16 16]A
[lp-1  ] DEBUG 2023/04/11 15:00:30 detected active phases: 3p
[lp-1  ] DEBUG 2023/04/11 15:00:30 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:30 charger status: C
[lp-1  ] DEBUG 2023/04/11 15:00:30 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:30 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:30 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:30 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:30 pv charge current: 0A = 6A + -8.11A (5594W @ 3p)
[site  ] DEBUG 2023/04/11 15:00:40 ----
[lp-1  ] DEBUG 2023/04/11 15:00:40 charge power: 11532W
[site  ] DEBUG 2023/04/11 15:00:40 pv power: 6754W
[site  ] DEBUG 2023/04/11 15:00:40 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:40 battery power: 4570W
[site  ] DEBUG 2023/04/11 15:00:40 grid power: 905W
[site  ] DEBUG 2023/04/11 15:00:40 site power: 5575W
[lp-1  ] DEBUG 2023/04/11 15:00:40 charge currents: [15.8 16 16]A
[lp-1  ] DEBUG 2023/04/11 15:00:40 detected active phases: 3p
[lp-1  ] DEBUG 2023/04/11 15:00:40 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:40 charger status: C
[lp-1  ] DEBUG 2023/04/11 15:00:40 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:40 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:40 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:40 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:40 pv charge current: 0A = 6A + -8.08A (5575W @ 3p)
[site  ] DEBUG 2023/04/11 15:00:50 ----
[lp-1  ] DEBUG 2023/04/11 15:00:50 charge power: 11532W
[site  ] DEBUG 2023/04/11 15:00:50 pv power: 6722W
[site  ] DEBUG 2023/04/11 15:00:50 battery soc: 100%
[site  ] DEBUG 2023/04/11 15:00:50 battery power: 4560W
[site  ] DEBUG 2023/04/11 15:00:50 grid power: 851W
[site  ] DEBUG 2023/04/11 15:00:50 site power: 5511W
[lp-1  ] DEBUG 2023/04/11 15:00:50 charge currents: [15.8 16 16]A
[lp-1  ] DEBUG 2023/04/11 15:00:50 detected active phases: 3p
[lp-1  ] DEBUG 2023/04/11 15:00:50 charge meter total import: 788.745kWh
[lp-1  ] DEBUG 2023/04/11 15:00:50 charger status: C
[lp-1  ] DEBUG 2023/04/11 15:00:50 soc estimated: 77.00% (vehicle: 77.00%)
[lp-1  ] DEBUG 2023/04/11 15:00:50 vehicle soc: 77%
[lp-1  ] DEBUG 2023/04/11 15:00:50 vehicle soc limit: 100%
[lp-1  ] DEBUG 2023/04/11 15:00:50 vehicle range: 371km
[lp-1  ] DEBUG 2023/04/11 15:00:50 pv charge current: 0A = 6A + -7.99A (5511W @ 3p)
[site  ] DEBUG 2023/04/11 15:01:00 ----

What type of operating system are you running?

Docker container

Version

0.115.0

@VolkerK62
Copy link
Contributor

[lp-1 ] DEBUG 2023/04/11 15:00:01 max charge current: 6A
So wie es aussieht, hat die Box diese Anweisung nicht befolgt.

@GrimmiMeloni
Copy link
Collaborator Author

OK, das würde es schon mal erklären.
Der max charge current wird während des Umschaltens von 1p auf 3p gesetzt. Vielleicht geht das dabei irgendwie unter. Könnte ein Verhalten speziell der Easee sein - ist aber reine Mutmaßung meinerseits.

Was mich aber wundert, ist das EVCC den macharge current nicht erneut auf der Box setzt. Wenn 10 Sekunden später die nächsten Metriken gezeigt werden, ist es ja auch für EVCC ersichtlich, daß die Box mit mehr als den eingestellten 6A lädt. Hier würde ich erwarten, daß dann nochmal wieder der Wert gesetzt wird um das zu korrigieren.

@VolkerK62
Copy link
Contributor

Wenn von der Box keine Fehlermeldung kommt, geht evcc davon aus, dass die Anweisung umgesetzt wird.
Die Antwort auf die Ergebnis der Nichtbeachtung kommt ja auch danach:
[lp-1 ] DEBUG 2023/04/11 15:00:10 phase scale1p in 3m0s

@andig
Copy link
Member

andig commented Apr 11, 2023

Die Frage geht an den Easee Support warum ein erfolgreicher Apiaufruf ignoriert wird.

@andig andig closed this as completed Apr 11, 2023
@andig andig added the question Rather clarification than issue label Apr 11, 2023
@naltatis
Copy link
Member

@GrimmiMeloni bitte lass mal Easee bei dir auf Trace laufen und Poste mal den Log-Ausschnitt nach dem Phasenwechsel wenn das noch mal wieder passiert.

levels:
  easee: trace

@GrimmiMeloni
Copy link
Collaborator Author

@naltatis wird gemacht

@andig wieso direkt zu? Ich kann zwar durchaus nachvollziehen, daß es sich hier mit hoher Wahrscheinlichkeit um ein Easee Problem handelt. Ich habe aber weiter oben auch erläutert wie es möglich wäre durch evcc das ganze nochmal zu versuchen. Zu erkennen das der API Aufruf ignoriert wurde ist ja bereits an Hand der Logs erkennbar. Somit wäre es ja auch kein Problem den Aufruf zu wiederholen. Das würde das Gesamtsystem zumindest stabiler machen.

@andig
Copy link
Member

andig commented Apr 11, 2023

Erstmal dürfen wir erwarten, dass erfolgreich Befehle auch genau das sind. Wenn nein ists ein Produktfehler bei dem dir Easee helfen sollte.

@evcc-io evcc-io locked and limited conversation to collaborators Apr 11, 2023
@andig andig converted this issue into discussion #7366 Apr 11, 2023

This issue was moved to a discussion.

You can continue the conversation there. Go to discussion →

Labels
question Rather clarification than issue
Projects
None yet
Development

No branches or pull requests

4 participants