Skip to content

Releases: hugen79/NanoVNA-H

Synchronize the source code to DiSlord version 1.2.27

20 Feb 05:53
Compare
Choose a tag to compare
Use the modified chibios submodule from the 7z file.

Synchronize DiSlord's version 1.2.14 code

31 Aug 01:41
Compare
Choose a tag to compare
Update to DiSlord version 1.2.14 code for better and faster display.

You can check NanoVNA-D for detailed update logs.
https://github.com/DiSlord/NanoVNA-D/

Synchronize DiSlord's version 1.1.01 code

29 Dec 16:27
Compare
Choose a tag to compare

Synchronize DiSlord's version 1.1.01 code, including admittance display and remote screen.
The use of MS5351 as a replacement for Si5351 is officially supported from this release. It can be modified via CONFIG>EXPERT SETTINGS>MORE>MODE.

The released firmware file name contains SI with the initial value using Si5351 and the file name contains MS with the initial value using Ms5351.
No matter which firmware, you can still modify it through the EXPERT SETTINGS menu.

Sync DiSlord version 1.1

11 Dec 12:56
Compare
Choose a tag to compare

Adjusted support for MS5351M
6x10 fonts look good on 2.8" NanoVNA, not compiled bold font version for 2.8".

Synchronize DiSlord1.0.71 version

21 Nov 12:07
Compare
Choose a tag to compare

Synchronize DiSlord1.0.71 version,
Now you can set the time through the "Expert Setting" menu.
Both the newly sold NanoVNA-H Rev3.6 and NanoVNA-H4 Rev4.3 have installed a 36.768kHz crystal, and the LSE can be used to keep the time correct after shutting down.
Add a 6x11 font version to the 2.8-inch NanoVNA-H to enhance readability as much as possible while maintaining dual-column display. Thanks to DiSlord for providing the new font file.

The NanoVNA-H update file containing B in the file name uses 7x11 bold font, and the file containing L uses 6x11 light font.
NanoVNA-H4 uses a larger screen, which can display 7x11 bold fonts well. Only the bold font version is available.

1.0.70

09 Oct 02:05
Compare
Choose a tag to compare

Synchronize DiSlord's 1.0.70 code.
https://github.com/DiSlord/NanoVNA-D

1.0.69

16 Sep 07:40
Compare
Choose a tag to compare

Based on the source code of DiSlord version 1.0.69, merge the source code of NanoVNA-H and NanoVNA-H4, which can be specified by TARGET when compiling. NanoVNA-H uses larger fonts, the display layout is adjusted for larger fonts, and you can set whether to use large fonts on NanoVNA-H by USE_FONT.

1.0.45

28 Jan 13:01
dd8d6bd
Compare
Choose a tag to compare

Modified based on DiSlord version 1.0.45 firmware. I uses a larger font similar to tinySA to display the menu and Marker point information, so the AA version is no longer provided.The default si5351 harmonic switching frequency is modified to 290MHz to ensure that si5351 can work normally in most cases. On the NanoVNA-H rev3.5 version, I tested that it can still ensure good measurement accuracy up to 1.8GHz, so this version allows the maximum frequency to be modified to 2GHz. If you want to get the latest features, you can start compiling from DiSlord's NanoVNA-D project.

NanoVNA-H4 version compiled on Feb 21, 2020

21 Feb 06:45
Compare
Choose a tag to compare

This update file is only for the 4-inch version NanoVNA-H 4 ! ! !

1.Fix the problem of insensitive touch screen;
2. Fixed the problem that the center frequency is higher than 1G;
3. Fix the problem of mark residue;
4. Update ChibiOS to 18.2
5. Correct the battery display ratio
6. Allow saving Smith display format settings

NanoVNA-H version compiled on January 18th, 2020

18 Jan 16:06
Compare
Choose a tag to compare

请注意:从NanoVNA-H rev3.4开始 D2使用IN4148,如果您的NanoVNA的D2是肖特基二极管,请使用"vbat_offset 150" 命令校准电池电压。
Please note: Starting with NanoVNA-H rev3.4 D2 uses IN4148, if your NanoVNA D2 is a Schottky diode, use the "vbat_offset 150" command to calibrate the battery voltage.

NanoVNA-H4是用于安装了stm32f303 MCU和4英寸显示器的版本。
The NanoVNA-H4 is a version for installing the stm32f303 MCU and 4-inch displays.