Issue In XDS, a Registry shall support replace, transform, append and folders, but these are optional for the Source. In ITI-65, you have specifies warning or error messages for a Doc Recipient that does not support these, but I think those warnings could only be returned by a Doc Recipient w/ no options (ie minimal metadata). A Doc Recipient that supports XDS on FHIR option certainly should not return those errors. I'm not sure about a Recip that only supports the Comprehensive Metadata option
Proposed Change If the above is true, we need to say that.
Priority:
Medium: Significant issue or clarification. Requires discussion, but should not lead to long debate.
The text was updated successfully, but these errors were encountered:
Section Number https://profiles.ihe.net/ITI/MHD/ITI-65.html#expected-actions
Issue In XDS, a Registry shall support replace, transform, append and folders, but these are optional for the Source. In ITI-65, you have specifies warning or error messages for a Doc Recipient that does not support these, but I think those warnings could only be returned by a Doc Recipient w/ no options (ie minimal metadata). A Doc Recipient that supports XDS on FHIR option certainly should not return those errors. I'm not sure about a Recip that only supports the Comprehensive Metadata option