Skip to content

Commit

Permalink
Common: rename SMART_BATTERY_INFO to BATTERY_INFO and add SOH (#2070)
Browse files Browse the repository at this point in the history
* common: rename smart-battery-info to battery-info

also removed extension tag

* common: battery-info gets SOH field

* BATTERY_INFO - align with DroneCan BatteryPeriodic

* Add WIP until implemented

---------

Co-authored-by: Hamish Willee <hamishwillee@gmail.com>
  • Loading branch information
rmackay9 and hamishwillee committed Feb 7, 2024
1 parent 3865b31 commit 4fef7de
Showing 1 changed file with 26 additions and 19 deletions.
45 changes: 26 additions & 19 deletions message_definitions/v1.0/common.xml
Original file line number Diff line number Diff line change
Expand Up @@ -6379,7 +6379,7 @@
<field type="float" name="yaw_rate" units="rad/s">Angular rate in yaw axis</field>
</message>
<message id="147" name="BATTERY_STATUS">
<description>Battery information. Updates GCS with flight controller battery status. Smart batteries also use this message, but may additionally send SMART_BATTERY_INFO.</description>
<description>Battery information. Updates GCS with flight controller battery status. Smart batteries also use this message, but may additionally send BATTERY_INFO.</description>
<field type="uint8_t" name="id" instance="true">Battery ID</field>
<field type="uint8_t" name="battery_function" enum="MAV_BATTERY_FUNCTION">Function of the battery</field>
<field type="uint8_t" name="type" enum="MAV_BATTERY_TYPE">Type (chemistry) of the battery</field>
Expand Down Expand Up @@ -7362,26 +7362,33 @@
<field type="int32_t" name="y">Y coordinate of center point. Coordinate system depends on frame field: local = x position in meters * 1e4, global = latitude in degrees * 1e7.</field>
<field type="float" name="z" units="m">Altitude of center point. Coordinate system depends on frame field.</field>
</message>
<message id="370" name="SMART_BATTERY_INFO">
<description>Smart Battery information (static/infrequent update). Use for updates from: smart battery to flight stack, flight stack to GCS. Use BATTERY_STATUS for smart battery frequent updates.</description>
<message id="370" name="BATTERY_INFO">
<wip/>
<description>
Battery information that is static, or requires infrequent update.
This message should requested using MAV_CMD_REQUEST_MESSAGE and/or streamed at very low rate.
BATTERY_STATUS_V2 is used for higher-rate battery status information.
</description>
<field type="uint8_t" name="id" instance="true">Battery ID</field>
<field type="uint8_t" name="battery_function" enum="MAV_BATTERY_FUNCTION">Function of the battery</field>
<field type="uint8_t" name="type" enum="MAV_BATTERY_TYPE">Type (chemistry) of the battery</field>
<field type="int32_t" name="capacity_full_specification" units="mAh" invalid="-1">Capacity when full according to manufacturer, -1: field not provided.</field>
<field type="int32_t" name="capacity_full" units="mAh" invalid="-1">Capacity when full (accounting for battery degradation), -1: field not provided.</field>
<field type="uint16_t" name="cycle_count" invalid="UINT16_MAX">Charge/discharge cycle count. UINT16_MAX: field not provided.</field>
<field type="char[16]" name="serial_number" invalid="[0]">Serial number in ASCII characters, 0 terminated. All 0: field not provided.</field>
<field type="char[50]" name="device_name" invalid="[0]">Static device name in ASCII characters, 0 terminated. All 0: field not provided. Encode as manufacturer name then product name separated using an underscore.</field>
<field type="uint16_t" name="weight" units="g" invalid="0">Battery weight. 0: field not provided.</field>
<field type="uint16_t" name="discharge_minimum_voltage" units="mV" invalid="UINT16_MAX">Minimum per-cell voltage when discharging. If not supplied set to UINT16_MAX value.</field>
<field type="uint16_t" name="charging_minimum_voltage" units="mV" invalid="UINT16_MAX">Minimum per-cell voltage when charging. If not supplied set to UINT16_MAX value.</field>
<field type="uint16_t" name="resting_minimum_voltage" units="mV" invalid="UINT16_MAX">Minimum per-cell voltage when resting. If not supplied set to UINT16_MAX value.</field>
<extensions/>
<field type="uint16_t" name="charging_maximum_voltage" units="mV" invalid="0">Maximum per-cell voltage when charged. 0: field not provided.</field>
<field type="uint8_t" name="battery_function" enum="MAV_BATTERY_FUNCTION">Function of the battery.</field>
<field type="uint8_t" name="type" enum="MAV_BATTERY_TYPE">Type (chemistry) of the battery.</field>
<field type="uint8_t" name="state_of_health" units="%" invalid="UINT8_MAX">State of Health (SOH) estimate. Typically 100% at the time of manufacture and will decrease over time and use. -1: field not provided.</field>
<field type="uint8_t" name="cells_in_series" invalid="0">Number of battery cells in series. 0: field not provided.</field>
<field type="uint32_t" name="discharge_maximum_current" units="mA" invalid="0">Maximum pack discharge current. 0: field not provided.</field>
<field type="uint32_t" name="discharge_maximum_burst_current" units="mA" invalid="0">Maximum pack discharge burst current. 0: field not provided.</field>
<field type="char[11]" name="manufacture_date" invalid="[0]">Manufacture date (DD/MM/YYYY) in ASCII characters, 0 terminated. All 0: field not provided.</field>
<field type="uint16_t" name="cycle_count" invalid="UINT16_MAX">Lifetime count of the number of charge/discharge cycles (https://en.wikipedia.org/wiki/Charge_cycle). UINT16_MAX: field not provided.</field>
<field type="uint16_t" name="weight" units="g" invalid="0">Battery weight. 0: field not provided.</field>
<field type="float" name="discharge_minimum_voltage" units="V" invalid="0">Minimum per-cell voltage when discharging. 0: field not provided.</field>
<field type="float" name="charging_minimum_voltage" units="V" invalid="0">Minimum per-cell voltage when charging. 0: field not provided.</field>
<field type="float" name="resting_minimum_voltage" units="V" invalid="0">Minimum per-cell voltage when resting. 0: field not provided.</field>
<field type="float" name="charging_maximum_voltage" units="V" invalid="0">Maximum per-cell voltage when charged. 0: field not provided.</field>
<field type="float" name="charging_maximum_current" units="A" invalid="0">Maximum pack continuous charge current. 0: field not provided.</field>
<field type="float" name="nominal_voltage" units="V" invalid="0">Battery nominal voltage. Used for conversion between Wh and Ah. 0: field not provided.</field>
<field type="float" name="discharge_maximum_current" units="A" invalid="0">Maximum pack discharge current. 0: field not provided.</field>
<field type="float" name="discharge_maximum_burst_current" units="A" invalid="0">Maximum pack discharge burst current. 0: field not provided.</field>
<field type="float" name="design_capacity" units="Ah" invalid="0">Fully charged design capacity. 0: field not provided.</field>
<field type="float" name="full_charge_capacity" units="Ah" invalid="NaN">Predicted battery capacity when fully charged (accounting for battery degradation). NAN: field not provided.</field>
<field type="char[9]" name="manufacture_date" invalid="[0]">Manufacture date (DDMMYYYY) in ASCII characters, 0 terminated. All 0: field not provided.</field>
<field type="char[32]" name="serial_number" invalid="[0]">Serial number in ASCII characters, 0 terminated. All 0: field not provided.</field>
<field type="char[50]" name="name" invalid="[0]">Battery device name. Formatted as manufacturer name then product name, separated with an underscore (in ASCII characters), 0 terminated. All 0: field not provided.</field>
</message>
<message id="373" name="GENERATOR_STATUS">
<description>Telemetry of power generation system. Alternator or mechanical generator.</description>
Expand Down

0 comments on commit 4fef7de