Z:\ChoFIT>chofit3_min.exe input-angiotensin.dat output-angiotensin 100 1400 32 32 32 0
Program: CHOFIT3_MIN 20150315 Test Version
InFile : Z:\ChoFIT\input-angiotensin.dat
OutFile: Z:\ChoFIT\output-angiotensin.fit
Low MW : 100 High MW : 1400
Low C : 1 High C : 1
Low H : 2 High H : 2
Low O : 0 High O : 0
Low N : 0 High N : 24
Low S : 0 High S : 8
Low P : 0 High P : 4
Low Na : 0 High Na : 0
Low 13C: 0 High 13C: 0
Processing ID 2
Writing the output file...
Press ENTER to close the program...
Now the "high MW" numbers seem incorrect, but I am not sure how to set them.
Also the ouput file did not contain any formula that contained the correct solution of
C50H72N13O15P.
Where can I set the mass accuracy? Maybe that will solve it.
Maybe some more examples would help too, where do I set the limits for CHO etc.
Thanks
Tobias
The text was updated successfully, but these errors were encountered:
You are right about mass accuracy, it is set to a default of 0.4 ppm, which is likely below the error. I've uploaded the modified HR2 code, so have a look.
There is a more functional chofit code, but I'd need to get permission to add to a public repository, and the added features are slightly more geared towards the problem of multiple formulae. It may still see light some day. The modified hr2 code, I did the work on and so I'm comfortable putting it on github.
There is a built in example (exe, input files, batch script). It does nothing but run the programs and calculate the elapsed times. Either way, both the source codes and a couple sample input files are there.
There are a couple bugs:
I disabled the charge handling (at line 482). This might not be a bug at all, but I haven't re-enabled it or tested. Without fixing it, the input masses are limited to neutral masses.
Si is missing (in a couple of my sums). So adding it as an element will cause errors. This is a simple fix, and one I just noticed.
I'm not sure if other issues of the chofit program apply to the modified hr2 program. About the limits for CHO in the lmm-based programs, they are no longer needed to set the loop ranges, however, they could be implemented (when the formula is checked) to filter the result to a certain range.
Hi,
tried to input Angiotensin C50H72N13O15P
Composition C:38-95 H:0-210 N:0-32 O:0-64 P:0-12 S:0-12
The input file input-angiotensin.dat
Angiotensin-Example
Now the "high MW" numbers seem incorrect, but I am not sure how to set them.
Also the ouput file did not contain any formula that contained the correct solution of
C50H72N13O15P.
Where can I set the mass accuracy? Maybe that will solve it.
Maybe some more examples would help too, where do I set the limits for CHO etc.
Thanks
Tobias