Fin Origin Problem - y adjusts both x&y (CR #803) #9
Labels
Defect
Includes code to repair a defect in EnergyPlus
SeverityMedium
This defect is medium severity, indicating moderate impact and generally no workaround available
Added on 1999-10-28 14:58 by @mjwitte
Description
MJW 99.10.28
The x-coordinate for Vertex 1 on a fin appears to be ignored, and the y-coordinate appears to adjust both the x & y positions of the fin origin.
see test files:defect files:042-case630.idf, dxf
See work around and solution...
MJW 99.11.10
With a fixed input (solar=+1, and schedules correct), verified that the fin placement for the simulation appeared to be working properly, just the dxf picture showed the fins in the wrong place.
revised 042-case620.idf checked in.
MJW 99.11.10
Indeed, it was just an error in the dxf picture, the thermal answers did not change. Fixed dxf checked in.
Workaround
This deck has a couple of problems. No Trans schedule is specified for the fins or overhangs. There is also no SCHX schedule which is used in Infiltration.
Fix
I believe the fins are now "fixed" for at least building north=0 and zone north=0. Need to implement the "north arrow" to help make sure others around the axis work equally well.
External Ref: 42
Addressed in
99.11.17 Build of EnergyPlus
Last build tested:
99.10.28 Build of EnergyPlus
The text was updated successfully, but these errors were encountered: