Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

NTR: Temperature of ADCP transducer (BODCNVS-1714) #193

Closed
JordanAthertonNOC opened this issue Mar 9, 2023 · 2 comments
Closed

NTR: Temperature of ADCP transducer (BODCNVS-1714) #193

JordanAthertonNOC opened this issue Mar 9, 2023 · 2 comments
Assignees

Comments

@JordanAthertonNOC
Copy link

JordanAthertonNOC commented Mar 9, 2023

Term to be modelled as:
Temperature of the water body by in-situ thermistor on acoustic doppler current profiler (ADCP) transducer

Based on the existing term:
TEMPTC01

Will NOT require the creation of one new S29 term.

@JordanAthertonNOC JordanAthertonNOC self-assigned this Mar 9, 2023
@JordanAthertonNOC
Copy link
Author

This term may instead need to be modelled as:

Temperature of the water body by.... 'thermistor on ADCP transducer' or similar. The temperature of the transducer itself doesn't seem to be used for anything, whereas water temp is routinely used for speed of sound correction. Confirmation sought from originator as to the intention behind this parameter.

@JordanAthertonNOC JordanAthertonNOC changed the title NTR: Temperature of ADCP transducer NTR: Temperature of ADCP transducer (BODCNVS-1714) Mar 9, 2023
@JordanAthertonNOC
Copy link
Author

One new P01 term created, will be live on the NVS by ~07:30 tomorrow:

TEMPTADC Temperature of the water body by in-situ thermistor on acoustic doppler current profiler (ADCP) transducer