Three things we want PVAnalytics to tell us about PV systems with single-axis trackers (to start).
does the system have a tracker (based on power or POA irradiance)
does it have a fixed orientation
If it does have a tracker, which days is the tracker functioning correctly (and which days is it stuck)
The first two can be addressed by #49 which uses an envelope fitting strategy. The third point can be addressed by #52. Other techniques (e.g. https://doi.org/10.1002/pip.3002) can also be applied to the third point given more information about the system.