I have a WB-CARRIER-BOARD-EI and have successfully began charging an EV with it. I also have a WB-CARRIER-BOARD-PI. For further development and trouble shooting, I'm wondering if the I one WB module could be configured in a passive (listen-only) mode to act as sniffer of communication between existing EV-EVSE, where it does not send any messages or participate in slac negotiation, and it only acts as a bridge to pass through PLC communication? I'm aware of the port mirror mode. Can this mode be operated as described?
The text was updated successfully, but these errors were encountered:
Hi ecmhk, tracing a communication between EV and EVSE where you don't have access to a mirror port on one of these participants can not be achieved using White Beet. But there are solutions available. Feel free to contact us directly: info@sevenstax.de
BR
I have a WB-CARRIER-BOARD-EI and have successfully began charging an EV with it. I also have a WB-CARRIER-BOARD-PI. For further development and trouble shooting, I'm wondering if the I one WB module could be configured in a passive (listen-only) mode to act as sniffer of communication between existing EV-EVSE, where it does not send any messages or participate in slac negotiation, and it only acts as a bridge to pass through PLC communication? I'm aware of the port mirror mode. Can this mode be operated as described?