Notifications
You must be signed in to change notification settings - Fork 0
/
dbus-fzsonick-48tl.py
472 lines (324 loc) · 15 KB
/
dbus-fzsonick-48tl.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
#!/usr/bin/python2 -u
# coding=utf-8
import re
import gobject
import sys
import logging
import config as cfg
import convert as c
import threading
from threading import Lock
mutex = Lock()
from pymodbus.register_read_message import ReadInputRegistersResponse
from pymodbus.client.sync import ModbusSerialClient as Modbus
from pymodbus.other_message import ReportSlaveIdRequest
from pymodbus.exceptions import ModbusException
from pymodbus.pdu import ExceptionResponse
from dbus.mainloop.glib import DBusGMainLoop
from data import BatteryStatus, Signal, Battery, LedColor
from collections import Iterable
from os import path
app_dir = path.dirname(path.realpath(__file__))
sys.path.insert(1, path.join(app_dir, 'ext', 'velib_python'))
from vedbus import VeDbusService as DBus
# trick the pycharm type-checker into thinking Callable is in scope, not used at runtime
# noinspection PyUnreachableCode
if False:
from typing import Callable
def init_signals(hardware_version, firmware_version, instance, n_batteries):
# type: (str,str,int) -> Iterable[Signal]
"""
A Signal holds all information necessary for the handling of a
certain datum (e.g. voltage) published by the battery.
Signal(dbus_path, aggregate, get_value, get_text = str)
dbus_path: str
object_path on DBus where the datum needs to be published
aggregate: Iterable[object] -> object
function that combines the values of multiple batteries into one.
e.g. sum for currents, or mean for voltages
get_value: (BatteryStatus) -> object [optional]
function to extract the datum from the modbus record,
alternatively: a constant
get_text: (object) -> unicode [optional]
function to render datum to text, needed by DBus
alternatively: a constant
The conversion functions use the same parameters (e.g scale_factor, offset)
as described in the document 'T48TLxxx ModBus Protocol Rev.7.1' which can
be found in the /doc folder
"""
product_id_hex = '0x{0:04x}'.format(cfg.PRODUCT_ID)
read_voltage = c.read_float(register=999, scale_factor=0.01, offset=0)
read_current = c.read_float(register=1000, scale_factor=0.01, offset=-10000)
def read_power(status):
return int(read_current(status) * read_voltage(status))
def max_current(status):
return status.battery.ampere_hours/2
product_name = cfg.PRODUCT_NAME
if n_batteries > 1:
product_name = cfg.PRODUCT_NAME + ' x' + str(n_batteries)
return [
Signal('/Dc/0/Voltage', c.mean, get_value=read_voltage, get_text=c.append_unit('V')),
Signal('/Dc/0/Current', sum, get_value=read_current, get_text=c.append_unit('A')),
Signal('/Dc/0/Power', sum, get_value=read_power, get_text=c.append_unit('W')),
Signal('/BussVoltage', c.mean, c.read_float(register=1001, scale_factor=0.01, offset=0), c.append_unit('V')),
Signal('/Soc', c.mean, c.read_float(register=1053, scale_factor=0.1, offset=0), c.append_unit('%')),
Signal('/Dc/0/Temperature', c.mean, c.read_float(register=1003, scale_factor=0.1, offset=-400), c.append_unit(u'°C')),
Signal('/Diagnostics/WarningFlags', c.first, c.read_hex_string(register=1005, count=4)),
Signal('/Diagnostics/AlarmFlags', c.first, c.read_hex_string(register=1009, count=4)),
Signal('/Diagnostics/BmsVersion', c.first, lambda s: s.battery.bms_version),
Signal('/Diagnostics/LedStatus/Red', c.first, c.read_led_state(register=1004, led=LedColor.red)),
Signal('/Diagnostics/LedStatus/Blue', c.first, c.read_led_state(register=1004, led=LedColor.blue)),
Signal('/Diagnostics/LedStatus/Green', c.first, c.read_led_state(register=1004, led=LedColor.green)),
Signal('/Diagnostics/LedStatus/Amber', c.first, c.read_led_state(register=1004, led=LedColor.amber)),
Signal('/Diagnostics/IoStatus/MainSwitchClosed', any, c.read_bool(register=1013, bit=0)),
Signal('/Diagnostics/IoStatus/AlarmOutActive', any, c.read_bool(register=1013, bit=1)),
Signal('/Diagnostics/IoStatus/InternalFanActive', any, c.read_bool(register=1013, bit=2)),
Signal('/Diagnostics/IoStatus/VoltMeasurementAllowed', any, c.read_bool(register=1013, bit=3)),
Signal('/Diagnostics/IoStatus/AuxRelay', any, c.read_bool(register=1013, bit=4)),
Signal('/Diagnostics/IoStatus/RemoteState', any, c.read_bool(register=1013, bit=5)),
Signal('/Diagnostics/IoStatus/HeaterOn', any, c.read_bool(register=1013, bit=6)),
# Two Level Alarms: 0=OK, 1=Warning, 2=Alarm
Signal('/Alarms/LowVoltage', max, c.read_alarm(warn_reg=1005, warn_bit=6, alarm_reg=1009, alarm_bit=7)), # Warn Low VBus < 40V (VBm1) / Alarm if < 39V (VBm2)
Signal('/Alarms/HighVoltage', max, c.read_alarm(warn_reg=1005, warn_bit=8, alarm_reg=1009, alarm_bit=9)), # Warn High VBus > 60V(VBM1) / Alarm if > 65V (VMB2)
Signal('/Alarms/LowSoc', max, c.read_alarm(warn_reg=1005, warn_bit=32, alarm_reg=1005, alarm_bit=35)), # Warn if not enough charging power is available on Vbus (BLPW) / Alarm if string_SOC < 5Ah (Ah_W)
Signal('/Alarms/HighChargeCurrent', max, c.read_alarm(warn_reg=1005, warn_bit=26, alarm_reg=1009, alarm_bit=27)), # Warn if string charge current > 9A (iCM1) / Alarm > 10A
Signal('/Alarms/HighDischargeCurrent', max, c.read_alarm(warn_reg=1005, warn_bit=10, alarm_reg=1009, alarm_bit=11)), # Warn if Ibatt_Discharge > 151A (IDM1) / Alarm > 160A
Signal('/Alarms/CellImbalance', max, c.read_alarm(warn_reg=1005, warn_bit=30, alarm_reg=1009, alarm_bit=31)), # Warn if String voltages unbalance (MID1) / Alarm (MID2)
Signal('/Alarms/InternalFailure', max, c.read_alarm(warn_reg=1009, warn_bit=20, alarm_reg=1009, alarm_bit=19)), # Warn if Hardware protection system is activated (HWEM) / Alarm if BMS hw fails (HWFL)
Signal('/Alarms/HighChargeTemperature', max, c.read_alarm(warn_reg=1005, warn_bit=1, alarm_reg=1009, alarm_bit=2)), # Warn if BMS Temp > 70ºC (TaM1) / Alarm > 85ºC (TaM2)
Signal('/Alarms/LowCellVoltage', max, c.read_alarm(warn_reg=1009, warn_bit=22, alarm_reg=1009, alarm_bit=23)), # Warn if Vstring < 39V (vsm1) / Alarm < 34V (vsm2)
Signal('/Alarms/LowTemperature', max, c.read_alarm(warn_reg=1009, warn_bit=3, alarm_reg=1009, alarm_bit=3)), # Alarm if low battery internal temperature is detected (Tbm)
Signal('/Alarms/HighTemperature', max, c.read_alarm(warn_reg=1005, warn_bit=4, alarm_reg=1009, alarm_bit=5)), # Warn if temp > 340ºC (TbM1) / Alarm > 350Â
Signal('/Mgmt/ProcessName', c.first, __file__),
Signal('/Mgmt/ProcessVersion', c.first, cfg.SOFTWARE_VERSION),
Signal('/Mgmt/Connection', c.first, cfg.CONNECTION),
# Signal('/DeviceInstance', c.first, cfg.DEVICE_INSTANCE),
Signal('/DeviceInstance', c.first, instance + cfg.DEVICE_INSTANCE),
Signal('/ProductName', c.first, product_name),
Signal('/ProductId', c.first, cfg.PRODUCT_ID, product_id_hex),
# see protocol doc page 7
Signal('/Info/MaxDischargeCurrent', sum, max_current, c.append_unit('A')),
Signal('/Info/MaxChargeCurrent', sum, max_current, c.append_unit('A')),
Signal('/Info/MaxChargeVoltage', min, cfg.MAX_CHARGE_VOLTAGE, c.append_unit('V')),
Signal('/Info/BatteryLowVoltage', max, cfg.MIN_BATTERY_VOLTAGE, c.append_unit('V')),
Signal('/Connected', c.first, 1),
Signal('/FirmwareVersion', c.first, cfg.FIRMWARE_VERSION, firmware_version),
Signal('/HardwareVersion', c.first, cfg.HARDWARE_VERSION, hardware_version)
]
def init_modbus(tty):
# type: (str) -> Modbus
logging.debug('initializing Modbus')
return Modbus(
port='/dev/' + tty,
method=cfg.MODE,
baudrate=cfg.BAUD_RATE,
stopbits=cfg.STOP_BITS,
bytesize=cfg.BYTE_SIZE,
timeout=cfg.TIMEOUT,
parity=cfg.PARITY)
def init_dbus(tty, signals):
# type: (str, Iterable[Signal]) -> DBus
logging.debug('initializing DBus service')
dbus = DBus(servicename=cfg.SERVICE_NAME_PREFIX + tty)
logging.debug('initializing DBus paths')
for signal in signals:
init_dbus_path(dbus, signal)
return dbus
# noinspection PyBroadException
def try_get_value(sig):
# type: (Signal) -> object
try:
return sig.get_value(None)
except:
return None
def init_dbus_path(dbus, sig):
# type: (DBus, Signal) -> ()
dbus.add_path(
sig.dbus_path,
try_get_value(sig),
gettextcallback=lambda _, v: sig.get_text(v))
def init_main_loop():
# type: () -> DBusGMainLoop
logging.debug('initializing DBusGMainLoop Loop')
DBusGMainLoop(set_as_default=True)
return gobject.MainLoop()
def report_slave_id(modbus, slave_address):
# type: (Modbus, int) -> str
slave = str(slave_address)
logging.debug('requesting slave id from node ' + slave)
try:
mutex.acquire()
modbus.connect()
request = ReportSlaveIdRequest(unit=slave_address)
response = modbus.execute(request)
if response is ExceptionResponse or issubclass(type(response), ModbusException):
raise Exception('failed to get slave id from ' + slave + ' : ' + str(response))
return response.identifier
finally:
modbus.close()
mutex.release()
def identify_battery(modbus, slave_address):
# type: (Modbus, int) -> Battery
logging.info('identifying battery...')
hardware_version, bms_version, ampere_hours = parse_slave_id(modbus, slave_address)
firmware_version = read_firmware_version(modbus, slave_address)
specs = Battery(
slave_address=slave_address,
hardware_version=hardware_version,
firmware_version=firmware_version,
bms_version=bms_version,
ampere_hours=ampere_hours)
logging.info('battery identified:\n{0}'.format(str(specs)))
return specs
def identify_batteries(modbus):
# type: (Modbus) -> list[Battery]
def _identify_batteries():
address_range = range(2, cfg.MAX_SLAVE_ADDRESS + 2)
for slave_address in address_range:
try:
yield identify_battery(modbus, slave_address)
except Exception as e:
logging.info('failed to identify battery at {0} : {1}'.format(str(slave_address), str(e)))
return list(_identify_batteries()) # force that lazy iterable!
def parse_slave_id(modbus, slave_address):
# type: (Modbus, int) -> (str, str, int)
slave_id = report_slave_id(modbus, slave_address)
sid = re.sub(r'[^\x20-\x7E]', '', slave_id) # remove weird special chars
match = re.match('(?P<hw>48TL(?P<ah>\d+)) *(?P<bms>.*)', sid)
if match is None:
raise Exception('no known battery found')
return match.group('hw'), match.group('bms'), int(match.group('ah'))
def read_firmware_version(modbus, slave_address):
# type: (Modbus, int) -> str
logging.debug('reading firmware version')
try:
mutex.acquire()
modbus.connect()
response = read_modbus_registers(modbus, slave_address, base_address=1054, count=1)
register = response.registers[0]
return '{0:0>4X}'.format(register)
finally:
modbus.close() # close in any case
mutex.release()
def read_modbus_registers(modbus, slave_address, base_address=cfg.BASE_ADDRESS, count=cfg.NO_OF_REGISTERS):
# type: (Modbus, int) -> ReadInputRegistersResponse
logging.debug('requesting modbus registers {0}-{1}'.format(base_address, base_address + count))
return modbus.read_input_registers(
address=base_address,
count=count,
unit=slave_address)
def read_battery_status(modbus, battery):
# type: (Modbus, Battery) -> BatteryStatus
"""
Read the modbus registers containing the battery's status info.
"""
logging.debug('reading battery status')
try:
mutex.acquire()
modbus.connect()
data = read_modbus_registers(modbus, battery.slave_address)
return BatteryStatus(battery, data.registers)
finally:
modbus.close() # close in any case
mutex.release()
def publish_values(dbus, signals, statuses):
# type: (DBus, Iterable[Signal], Iterable[BatteryStatus]) -> ()
for s in signals:
values = [s.get_value(status) for status in statuses]
dbus[s.dbus_path] = s.aggregate(values)
def update(modbus, batteries, dbus, signals):
# type: (Modbus, Iterable[Battery], DBus, Iterable[Signal]) -> bool
"""
Main update function
1. requests status record each battery via modbus,
2. parses the data using Signal.get_value
3. aggregates the data from all batteries into one datum using Signal.aggregate
4. publishes the data on the dbus
"""
logging.debug('starting update cycle')
statuses = [read_battery_status(modbus, battery) for battery in batteries]
publish_values(dbus, signals, statuses)
logging.debug('finished update cycle\n')
return True
def print_usage():
print ('Usage: ' + __file__ + ' <serial device>')
print ('Example: ' + __file__ + ' ttyUSB0')
def parse_cmdline_args(argv):
# type: (list[str]) -> str
if len(argv) == 0:
logging.info('missing command line argument for tty device')
print_usage()
sys.exit(1)
return argv[0]
alive = True # global alive flag, watchdog_task clears it, update_task sets it
def create_update_task(modbus, dbus, batteries, signals, main_loop):
# type: (Modbus, DBus, Iterable[Battery], Iterable[Signal], DBusGMainLoop) -> Callable[[],bool]
"""
Creates an update task which runs the main update function
and resets the alive flag
"""
def update_task():
# type: () -> bool
global alive
alive = update(modbus, batteries, dbus, signals)
if not alive:
logging.info('update_task: quitting main loop because of error')
main_loop.quit()
return alive
return update_task
def create_watchdog_task(main_loop):
# type: (DBusGMainLoop) -> Callable[[],bool]
"""
Creates a Watchdog task that monitors the alive flag.
The watchdog kills the main loop if the alive flag is not periodically reset by the update task.
Who watches the watchdog?
"""
def watchdog_task():
# type: () -> bool
global alive
if alive:
logging.debug('watchdog_task: update_task is alive')
alive = False
return True
else:
logging.info('watchdog_task: killing main loop because update_task is no longer alive')
main_loop.quit()
return False
return watchdog_task
def expose_battery(bat, bat_number, modbus, main_loop):
signals = init_signals(bat.hardware_version, bat.firmware_version,bat_number, 1)
dbus = init_dbus("bat_" + str( bat_number ), signals)
batteries = []
batteries.append(bat)
update_task = create_update_task(modbus, dbus, batteries, signals, main_loop)
watchdog_task = create_watchdog_task(main_loop)
gobject.timeout_add(cfg.UPDATE_INTERVAL * 2, watchdog_task) # add watchdog first
gobject.timeout_add(cfg.UPDATE_INTERVAL, update_task) # call update once every update_interval
dbus.__del__
def main(argv):
# type: (list[str]) -> ()
logging.basicConfig(level=cfg.LOG_LEVEL)
logging.info('starting ' + __file__)
tty = parse_cmdline_args(argv)
modbus = init_modbus(tty)
batteries = identify_batteries(modbus)
n = len(batteries)
logging.info('found ' + str(n) + (' battery' if n == 1 else ' batteries'))
if n <= 0:
sys.exit(2)
main_loop = init_main_loop() # must run before init_dbus because gobject does some global magic
threads = []
i = 0
for bat in batteries:
threads.append(threading.Thread(target = expose_battery, args = (bat, i, modbus, main_loop)))
i = i+1
for thread in threads:
thread.start();
for thread in threads:
thread.join()
logging.info('starting gobject.MainLoop')
main_loop.run()
logging.info('gobject.MainLoop was shut down')
sys.exit(0xFF) # reaches this only on error
if __name__ == "__main__":
main(sys.argv[1:])