Hi,
I found the Karplus Oscillator causes DC output if Decay is on 100%.
I tried a simple [clip~ 0. 0.999] at the 3rd inlet of the gen~ subpatcher; this does it well. Or perhaps better in the gen~ part.

btw: The Exponent 2. in the decay dial is a little problematic, as you get a usable range for the decay only in the last 10% of the dial range (IMO); I think 0.5 for the Exponent works better...

Cheers Rob