You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I'm seeing an API version issue with HDF5. For instance if I run the rectangular waveguide tutorial I see this output:
octave> source rect_waveguide.m
args = "rect_wg.xml"
----------------------------------------------------------------------
| openEMS 64bit -- version v0.0.35-45-gde23172
| (C) 2010-2018 Thorsten Liebig <thorsten.liebig@gmx.de> GPL license
----------------------------------------------------------------------
Used external libraries:
CSXCAD -- Version: v0.6.2-85-g55899d0
hdf5 -- Version: 1.10.4
compiled against: HDF5 library version: 1.10.4
tinyxml -- compiled against: 2.6.2
fparser
boost -- compiled against: 1_69
vtk -- Version: 8.1.2
compiled against: 8.1.2
Create FDTD operator (compressed SSE + multi-threading)
FDTD simulation size: 27x12x122 --> 39528 FDTD cells
FDTD timestep is: 7.79642e-13 s; Nyquist rate: 24 timesteps @2.67217e+10 Hz
Excitation signal length is: 1225 timesteps (9.55062e-10s)
Max. number of timesteps: 10000 ( --> 8.16327 * Excitation signal length)
Create FDTD engine (compressed SSE + multi-threading)
Running FDTD engine... this may take a while... grab a cup of coffee?!?
[@ 4s] Timestep: 3496 || Speed: 34.5 MC/s (1.144e-03 s/TS) || Energy: ~1.09e-30 (-81.26dB)
Time for 3496 iterations with 39528.00 cells : 4.00 sec
Speed: 34.54 MCells/s
warning: legend: 'best' not yet implemented for location specifier, using 'northeast' instead
warning: legend: 'best' not yet implemented for location specifier, using 'northeast' instead
error: API version api-v52+ found in .oct file function 'h5readatt_octave'
does not match the running Octave (API version api-v53)
this can lead to incorrect results or other failures
you can fix this problem by recompiling this .oct file
error: called from
ReadHDF5Attribute at line 22 column 10
ReadHDF5FieldData>ReadHDF5FieldData_octave at line 97 column 34
ReadHDF5FieldData at line 29 column 19
PlotHDF5FieldData at line 25 column 8
rect_waveguide at line 121 column 1
I believe I have the latest master versions of both Octave and OpenEMS. Have you encountered this issue? I'm using Arch Linux.
The text was updated successfully, but these errors were encountered:
I'm seeing an API version issue with HDF5. For instance if I run the rectangular waveguide tutorial I see this output:
I believe I have the latest master versions of both Octave and OpenEMS. Have you encountered this issue? I'm using Arch Linux.
The text was updated successfully, but these errors were encountered: