Rendering of historic sensor values broken in 2022.04 #15

Closed
alsFC opened this issue Apr 7, 2022 · 6 comments
Closed

Rendering of historic sensor values broken in 2022.04 #15

alsFC opened this issue Apr 7, 2022 · 6 comments
Assignees

Comments

@alsFC
Copy link

alsFC commented Apr 7, 2022

With the current 2022.04 Release the default rendering of history graphs of the sensors changed to bar charts. Probably defining of device_class and unit_of_measurement attributes for all sensors will solve the problem.

image

@alsFC
Copy link
Author

alsFC commented Apr 7, 2022

also state_class attribute would be nice to support system-native long term statistics.

@geni0602
Copy link

geni0602 commented Apr 7, 2022

Hi,
Same for me with the new update 2022.4. units of measurement are not available and no more history graph.
It will be nice, if you could fix it.

Thanks!

@weltmeyer weltmeyer self-assigned this Apr 7, 2022
@weltmeyer
Copy link
Owner

Didnt mean to close it directly before you also confirm this works with the latest update :)
Can you check please?

@weltmeyer weltmeyer reopened this Apr 7, 2022
@geni0602
Copy link

geni0602 commented Apr 7, 2022

It´s looking good. Units of measurement are fine and the graphs as well.

Thanks a lot!

@alsFC
Copy link
Author

alsFC commented Apr 7, 2022

All the sensors looking good now! 🙂
Thank you!

One thing: the actual state of the battery (charging, discharging, etc.) renders as graph now. Perhaps because unit_of_measurement and device_class are defined for this sensor as well but are set to none.

@weltmeyer
Copy link
Owner

All the sensors looking good now! 🙂 Thank you!

One thing: the actual state of the battery (charging, discharging, etc.) renders as graph now. Perhaps because unit_of_measurement and device_class are defined for this sensor as well but are set to none.

Should also be fixed with another update, thanks for reporting.

i am closing this now