When saving the configuration after auto leveling, you get the error SAVE_CONFIG section 'probe' option 'z_offset' conflicts with included value. The cause of this is that the [probe] configuration section is in the included file printer.base.cfg. Moving the [probe] section to the main printer.cfg resolves this issue.
The text was updated successfully, but these errors were encountered:
When saving the configuration after auto leveling, you get the error
SAVE_CONFIG section 'probe' option 'z_offset' conflicts with included value
. The cause of this is that the [probe] configuration section is in the included file printer.base.cfg. Moving the [probe] section to the main printer.cfg resolves this issue.The text was updated successfully, but these errors were encountered: