Skip to content

This is the official code for the paper "Transformer Based Feature Fusion for Left Ventricle Segmentation in 4D Flow MRI" MICCAI 2022, Singapore

Notifications You must be signed in to change notification settings

xsunn/TransfusionLVSegmentation

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

12 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Transformer Based Feature Fusion for Left Ventricle Segmentation in 4D Flow MRI

1. Introduction

The repository is the official code based on Pytorch for the paper of
"Transformer Based Feature Fusion for Left Ventricle Segmentation in 4D Flow MRI" MICCAI 2022, Singapore https://link.springer.com/chapter/10.1007/978-3-031-16443-9_36
Four-dimensional flow magnetic resonance imaging (4D Flow MRI) enables visualization of intra-cardiac blood flow and quantification of cardiac function using time-resolved three directional velocity data. Segmentation of cardiac 4D flow data is a big challenge due to the extremely poor contrast between the blood pool and myocardium. The magnitude and velocity images from a 4D flow acquisition provide complementary information, but how to extract and fuse these features efficiently is unknown. Automated cardiac segmentation methods from 4D flow MRI have not been fully investigated yet. In this paper, we take the velocity and magnitude image as the inputs of two branches separately, then propose a Transformer based cross- and self-fusion layer to explore the inter-relationship from two modalities and model the intra-relationship in the same modality. A large in-house dataset of 104 subjects (91,182 2D images) was used to train and evaluate our model using several metrics including the Dice, Average Surface Distance (ASD), end-diastolic volume (EDV), end-systolic volume (ESV), Left Ventricle Ejection Fraction (LVEF) and Kinetic Energy (KE). Our method achieved a mean Dice of 86.52%, and ASD of 2.51 mm. Evaluation on the clinical parameters demonstrated competitive results, yielding a Pearson correlation coefficient of 83.26%, 97.4%, 96.97% and 98.92% for LVEF, EDV, ESV and KE respectively.

2. Training data structure

The data structure is as following:

Data
└── Patient1
  ├── SAX4DFMAG
  ├── SAX4DFX
  ├── SAX4DFY
  ├── SAX4DFZ
└── Patient2
  ├── SAX4DFMAG
  ├── SAX4DFX
  ├── SAX4DFY
  ├── SAX4DFZ

The training data path is saved in TXT file as following:
.../DATA/Patient1/SAX4DFMASK/IM_sl0010_ph0001.dcm
.../DATA/Patient1/SAX4DFMASK/IM_sl0010_ph0002.dcm
...
...
...