PoE powered UZG-01 does not come online after reboot #44
Comments
Please provide additional information about the hardware version of UZG-01 (label on the bottom). |
Ok. No need. I'll check and come back. |
You could try to change |
Didn't help at all. I turned of power on the switchport and powered up the UZG-01 via USB-cable instead. The network port just blinked as before until I unplugged the usb cable, waited 10 seconds, and replugged it. This is becoming the most unstable piece of hardware I have purchased for a long time. Not possible to reboot without hassle |
I have the same issue with UZG-01 (POE-0.4) |
Let's separate Zigbee and ESP issues. I will look for some solution to made ESP32 works with LAN port more stable. |
You could try to change "pwrAltPin": 5, to "pwrAltPin": -1, in your configHW.json. Have you? |
It hasn't helped |
@mercenaruss could you help us ? |
I have the same issue on a UZG-POE-0.5. It doesn't always survive a reboot and am left with the NIC lights pulsing off and on again 3 times in a cycle. I have 2 of these devices, i think both with the same Hardware revisions based on the Status page (ESP32-D0WD-V3) and the sticker on the bottom (UZG-POE-0.5) but only one of them has this issue. I reboot the other one on a daily basis to install all the new firmware updates and it always reboots fine with no issues. (Just as well really as that one is in a remote site!) Happy to try any suggestions to help pinpoint the issue. |
@tonius7570 @zoptooniek Try to change "pwrAltPin": -1, to "pwrAltPin": -1, in your configHW.json. |
@mercenaruss changing this made no difference to me. I'm still in the same situation. |
Could you try factory reset after updating to 20240607* ? |
This seems to have done the trick so far. |
@zoptooniek could you check it later to confirm, and if no issues - close this issue ? |
@xyzroe - Performed a few more reboots and fw updates and all seems good! |
Not sure if this is related to the switch or the UZG-01
If I restart the UZG-01, it does not come back until I shutdown the switchport and turn it back on.
Until then, the UZG network port blinks for a second, then goes dark. Blinks for a second then goes dark, etc.
The switch is a Cisco Catalyst 9300 of model C9300L-48UXG-4X
The port settings looks like this:
The show power inline command shows this:
The configHW.json debug file contains this: