Notifications
You must be signed in to change notification settings - Fork 3k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Support for Hive Alarm Keypad #2967
Conversation
I'm not really sure as I haven't really read much of the IAS part of the spec, doing stuff in the onZigbeeEvent is probably indeed the way to go, but I think you need to add To be able to send your own responses. I also had a look on the ZA website and found this https://zigbeealliance.org/zigbee_products/keypad/ doesn't look 100% the same but I think it's the same device. And there is a compliance document available. https://api.knack.com/v1/applications/54e658034b4f44e42fb18201/download/asset/5b64246cc03e9d03cc4b342d/pics_keypad.rar Looks to be just the absolute basic word docs about genBasic, genIdentity, genPower, and genOta so pretty useless as usual. Below is probably the only really useful info: <cluster>
<name>IAS Zone</name>
<code>0x0500</code>
<define>IAS_ZONE_CLUSTER</define>
<attribute source="server" code="0x0000" define="ZONE_STATE" mandatory="true" name="zone state">TRUE</attribute>
<attribute source="server" code="0x0001" define="ZONE_TYPE" mandatory="true" name="zone type">TRUE</attribute>
<attribute source="server" code="0x0002" define="ZONE_STATUS" mandatory="true" name="zone status">TRUE</attribute>
<attribute source="server" code="0x0010" define="IAS_CIE_ADDRESS" mandatory="true" name="IAS CIE address">TRUE</attribute>
<attribute source="server" code="0x0011" define="ZONE_ID" mandatory="true" name="Zone ID">TRUE</attribute>
<attribute source="server" code="0x0012" define="NUMBER_OF_ZONE_SENSITIVITY_LEVELS_SUPPORTED" mandatory="false" name="Number of Zone Sensitivity Levels Supported">FALSE</attribute>
<attribute source="server" code="0x0013" define="CURRENT_ZONE_SENSITIVITY_LEVEL" mandatory="false" name="Current Zone Sensitivity Level">FALSE</attribute>
<command receivedBy="server" code="0x00" name="ZoneEnrollResponse" mandatory="true">TRUE</command>
<command receivedBy="server" code="0x01" name="InitiateNormalOperationMode" mandatory="false">FALSE</command>
<command receivedby="server" code="0x02" name="InitiateTestMode" mandatory="false">FALSE</command>
<command receivedBy="client" code="0x00" name="ZoneStatusChangeNotification" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x01" name="ZoneEnrollRequest" mandatory="true">TRUE</command>
</cluster> and <cluster>
<name>IAS ACE</name>
<code>0x0501</code>
<define>IAS_ACE_CLUSTER</define>
<attribute source="server" code="0x0000" define="PANEL_STATUS" mandatory="true" name="panel status">FALSE</attribute>
<command receivedBy="server" code="0x00" name="Arm" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x01" name="Bypass" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x02" name="Emergency" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x03" name="Fire" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x04" name="Panic" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x05" name="GetZoneIdMap" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x06" name="GetZoneInformation" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x07" name="GetPanelStatus" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x08" name="GetBypassedZoneList" mandatory="true">FALSE</command>
<command receivedBy="server" code="0x09" name="GetZoneStatus" mandatory="true">FALSE</command>
<command receivedBy="client" code="0x00" name="ArmResponse" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x01" name="GetZoneIdMapResponse" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x02" name="GetZoneInformationResponse" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x03" name="ZoneStatusChanged" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x04" name="PanelStatusChanged" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x05" name="GetPanelStatusResponse" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x06" name="SetBypassedZoneList" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x07" name="BypassResponse" mandatory="true">TRUE</command>
<command receivedBy="client" code="0x08" name="GetZoneStatusResponse" mandatory="true">TRUE</command>
</cluster> Page 511 of the v7 spec pdf does deal with IAS ACE it seems.
|
@sjorge Thanks for your input, yeah the device is made by the exact same company, but it doesn't seem to have motion detection, to turn on the keypad. Hive being cheap. This is basically the same as But rebranded. I am sure under the hood the firmware is fairly identical. I will try the meta thing and see how that goes. |
I am now reading through the original PR for Centralite, but might be a tomorrow problem. And the device documentation also shows that the I wonder if there is any reason why this can't be made into a functioning |
Scrap all of the above. The answer is to do confirmations over MQTT.... In the original PR the OP and Koen went through this and seems to have designed it this way. And it does make sense, since you need a 3rd party to decide, while z2m is just a data carrier in that sense. I will run some more tests and probably be done with this soon :) Thanks Jorge for opening my eyes about that spec. Made me understand better what i am looking, and then all of a sudden the code that I seeing for the other alarm keypads made sense! |
@Koenkk I just found a bug that you have introduced as part of a refractor in commit c0e84ec Initially you were using commons.js, which after adding support for Centralite Keypad looked like this. The important section is https://github.com/sparky3387/zigbee-herdsman-converters/blob/cabdf7647c2b038652bb2261f60d66a866e9a0d9/converters/common.js#L89 After the refractor toZigbee got changed: The commons mode was replaced with constants mode, which do not match the ZCL standard. This is if As a result, I will add a new const called I will do this tomorrow when i get a chance. |
I don't have any keypads to test with, but from reading the ZCL the changes make sense to me. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
LGTM
I have tested all possible outcomes on mine, and the device behaves as expected. With regards to my above post:
From the standard this would work in the following way:
|
And saying that, I think the code (more like usage logic) is still wrong. But i need your feedback before I change it. I am now inclined to think that That is because if you confirm the action like step 2., then whatever automation you use will use that attribute to decice the house is now armed. You open the door and you trigger the alarm. Instead I think the proper use should be Then the automation will change the armMode according to the rules, e.g. Can you two please review my logic? |
Another commit to resolve the conflict with #2974 It would be great if we could have a bit of a brain storm over my above comments. My suggestion would be to replace: with just This way the I need your input before making such a decision because changing this will cause a "breaking change" in terms of usability and should be mentioned in the Release Notes? To basically point to user to an updated version of their device's documentation on z2m.io |
Can we read armMode from the device, say after a timeout? |
Could you give an example of such issue? |
For the fix i did with constants:
For removing the leftover >3 condition
This is the real world usage of how an alarm is meant to work. (I have a Ring alarm in the house so I understand the behaviour, but I am doing the legwork to get myself ready to move to my own zigbee one) |
I see, I'm fine with it, could you also make a PR to update the docs? |
@Koenkk I have pushed the commit with the relevant comments. Yes I can update the documentation. Do you plan on releasing this change on tomorrow's release? If so, I will wait until then for the documents to generate automatically and then do a PR for my Hive and the other keypads to update the "Notes" sections. Does that work for you? |
Fine by me! Thanks both! |
Sounds good. Thanks @sjorge for putting up with my thought process |
np, sometimes it helps :) just reading the ZCL and looking at the device responses can sure as hell be confusing at times 😆 |
@Koenkk Do you mind please adding something in the Release Notes for keypad owners to keep an eye for an updated documentation? |
Would below be OK for you?
|
@Koenkk Use the term "keypad" somewhere in there. As realistically there is no alarm device, but rather a collection of them made to act as an alarm system. Apart from that yes all good. I will do PRs as soon as the release is happening |
@robertalexa, your change is really welcome, and as I see you have had a look on the PR #1873 before doing this one. But the original PR incorporated the 30 seconds exit delay beeping as well. Are you planning to add that as well? |
@GSzabados In the most recent code, I have not seen anything to do with 30 seconds delay, but i will look at the code one more time. Anyway, zigbee2mqtt should not keep track of this value, nor should it be fixed to 30seconds. The exit and entry delay should be tracked by the 3rd party automation solution (node-red for example). That is because people also need the option to decide how long they need, 10s, 30s 60s etc. Or even different values for exit and entry. e.g. entry is 30s and exit is only 15s. So a healthy flow would be this: Koenkk/zigbee2mqtt#8630 (comment) I hope this answers your question :) |
I didn't meant actually 30 seconds, but these variables/constants.
|
Yes, I know, but the PR what I was mentioning would have brought the panelStatus as active option with those parameters as changeable. Your PR as armNotification could use those parameters, as the keypad should give audiable output for exit_delay, just as an example. Have a look on that PR. And there was another discussion about it as well. I cannot remember where. I like the logic of the armNotification, makes sense. And solves some quirks with automations, but introduces other ones other places. If you do use HA, then maybe we should work on a Blueprint for these keypads on how to behave with an alarm server, like Alarmo. |
@GSzabados there is currently another chat about sounds, and it seems to be related to the command send. Koenkk/zigbee2mqtt#8630 (comment) But it is still tested. So maybe keep an eye on that thread too, regarding sounds. I see your logic about making those variables passthrough. I can have a look at code and try to assist you if you want to have that sorted out. Unfortunately i do not have the hive keypad anymore so i am unable to test anythinf any further. I bought it purely to support it in z2m and then returned and refunded it. Ps. I spoke with Linkind and they said they will start selling the keypad as an individual product, rather than bundle, somete this month. I might be that i buy it and have a play with it. |
I not really fuss about that, but wanted to suggest, try to bring in @dettrick for the development. He had some great ideas there. Otherwise the main problem for people to understand your new logic, is the missing alarm panel entity. There is no representation in HA what is the current status of the panel, unless you mirror your MQTT messages to a manual one. |
It is not so expensive in the kit and all the other bits are quite nice quality. Except the fact that everything has Linkind written on it with HUGE letters. Otherwise, I just managed to re-purpose recently the Hub as well. It can be connected to HA as a Zigbee dongle through the network. I haven't managed to make the Siren work yet, but it is on my to-do list. If interested, have a look here, I haven't made a write up yet, but the steps are quite straightforward: |
Few mentions please, if you indulge me. The logic I have applied in my PR was purely to bring functionality in line with ZCL standards. I haven't tried to "create" my own "vision". So in that respect, I am a simple messenger learning about this as I go :) With regards to the alarm panel status in HA, there was not a representation before in HA (unless I am missing something, please correct me if you know more), so I do not think I made things worse. Personally I do not know if there is a better way of "hooking" things up to a HA alarm panel other than manual. But I am also not using HA for my automations, I do use HA but I use node-red for anything that I do. So if I was to set sth like that up, my HA alarm panel would be something not connected to anything, and just plug it into my node-red flows. I am saying that there is not a simple way purely because you need a "brain" to the operation. I am sure HA can do that natively, but I lack the knowledge about this topic to even pursue it. And as mentioned before, I do not have a zigbee alarm system, I use an out of the box RIng alarm (at least for now). I hope this helps you better understand my position with regards to this alarm system thing haha :) (and my contribution) |
This change resulted in the infinity keypad not beeping anymore when armed. Why did the logic change? |
@thecobra666 could you please have a read through this thread? |
Will someone still use hive keypad? Looks that support is broken but did it work at some point? |
My Hive Keypad001 ends up with an error when I press a button: |
This is a continuation of Koenkk/zigbee2mqtt#8424
TIME SENSITIVE - I have purchased this item purely to provide support for it and I have no intention to keep it. My return date is 1st of September so I would appreciate if you could give me a hand with this @Koenkk @sjorge
I have a very rough initial support commit, most of the exposed attributes work, maybe even all, but I am unable to use the device, and I will explain further down. This is how it currently looks
My biggest issue is that the keypad becomes unresponsive after you press a button. That seems to be because the keypad wants a response after each command.
When you press any key, you initially get a command sent out
The keypad waits for a response, keypads do not beep anymore, the network icon flashes and then turns red.
I have also sniffed the packets, to the extent I was able to considering I didn't have motion sensors or door sensors to create an environment, and the Hive app doesn't allow me to arm the system with this.
Each command received from the keypad is always followed by a response. Here is a screenshot of the Response following the
commandGetPanelStatus
command, which is when you press a button from device sleep.Please have a look at my code and tell me what I am doing wrong. (Guide me senpais!)
Also, here are my notes from the sniffing (I have not saved the sniff, just noted down what i saw important and took screenshots, but if needs be, i can sniff again)
Thanks guys!